Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging

被引:11
作者
Velroyen, Astrid [1 ,2 ]
Bech, Martin [1 ,2 ,3 ]
Tapfer, Arne [1 ,2 ]
Yaroshenko, Andre [1 ,2 ]
Mueller, Mark [1 ,2 ]
Paprottka, Philipp [4 ]
Ingrisch, Michael [4 ]
Cyran, Clemens C. [4 ]
Auweter, Sigrid D. [4 ]
Nikolaou, Konstantin [4 ]
Reiser, Maximilian F. [4 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Lehrstuhl Biomed Phys, Dept Phys, Garching, Germany
[2] Tech Univ Munich, Inst Med, Garching, Germany
[3] Lund Univ, Med Radiat Phys, Lund, Sweden
[4] Univ Munich, Hosp Munich, Inst Clin Radiol, Munich, Germany
来源
PLOS ONE | 2015年 / 10卷 / 07期
基金
欧洲研究理事会;
关键词
DIFFERENTIAL PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; NANOPARTICLES; SIGNAL;
D O I
10.1371/journal.pone.0129512
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.
引用
收藏
页数:14
相关论文
共 47 条
  • [31] Construction and evaluation of a high-energy grating-based x-ray phase-contrast imaging setup
    Hauke, Christian
    Horn, Florian
    Pelzer, Georg
    Rieger, Jens
    Lachner, Sebastian
    Ludwig, Veronika
    Seifert, Maria
    Schuster, Max
    Wandner, Johannes
    Wolf, Andreas
    Weber, Thomas
    Michel, Thilo
    Anton, Gisela
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [32] Virtual differential phase-contrast and dark-field imaging of x-ray absorption images via deep learning
    Ge, Xin
    Yang, Pengfei
    Wu, Zhao
    Luo, Chen
    Jin, Peng
    Wang, Zhili
    Wang, Shengxiang
    Huang, Yongsheng
    Niu, Tianye
    BIOENGINEERING & TRANSLATIONAL MEDICINE, 2023, 8 (06)
  • [33] Linear information retrieval method in X-ray grating-based phase contrast imaging and its interchangeability with tomographic reconstruction
    Wu, Z.
    Gao, K.
    Wang, Z. L.
    Shao, Q. G.
    Hu, R. F.
    Wei, C. X.
    Zan, G. B.
    Wali, F.
    Luo, R. H.
    Zhu, P. P.
    Tian, Y. C.
    JOURNAL OF APPLIED PHYSICS, 2017, 121 (21)
  • [34] Quantification of dark-field effects in single-shot grid-based x-ray imaging
    Lim, Hyunwoo
    Cho, Hyosung
    Lee, Hunwoo
    Jeon, Duhee
    JOURNAL OF OPTICS, 2022, 24 (03)
  • [35] A first investigation of accuracy, precision and sensitivity of phase-based x-ray dark-field imaging
    Astolfo, Alberto
    Endrizzi, Marco
    Kallon, Gibril
    Millard, Thomas P.
    Vittoria, Fabio A.
    Olivo, Alessandro
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2016, 49 (48)
  • [36] Quantitative Assessment of Vulnerable Atherosclerotic Carotid Plaque: Comparison of Grating-Based X-Ray Phase Contrast Imaging and Histology
    Hetterich, Holger
    Fill, Sandra
    Herzen, Julia
    Bamberg, Fahian
    Willner, Marian
    Reiser, Maximilian
    Pfeiffer, Franz
    Saam, Tobias
    CIRCULATION, 2012, 126 (21)
  • [37] Analysis and correction of bias induced by phase stepping jitter in grating-based X-ray phase-contrast imaging
    de Marco, Fabio
    Marschner, Mathias
    Birnbacher, Lorenz
    Noel, Peter
    Herzen, Julia
    Pfeiffer, Franz
    OPTICS EXPRESS, 2018, 26 (10): : 12707 - 12722
  • [38] X-ray dark-field contrast imaging of water transport during hydration and drying of early-age cement-based materials
    Yang, Fei
    Prade, Friedrich
    Griffa, Michele
    Kaufmann, Rolf
    Herzen, Julia
    Pfeiffer, Franz
    Lura, Pietro
    MATERIALS CHARACTERIZATION, 2018, 142 : 560 - 576
  • [39] Qualitative and Quantitative Imaging Evaluation of Renal Cell Carcinoma Subtypes with Grating-based X-ray Phase-contrast CT
    Braunagel, Margarita
    Birnbacher, Lorenz
    Willner, Marian
    Marschner, Mathias
    De Marco, Fabio
    Viermetz, Manuel
    Notohamiprodjo, Susan
    Hellbach, Katharina
    Auweter, Sigrid
    Link, Vera
    Woischke, Christine
    Reiser, Maximilian F.
    Pfeiffer, Franz
    Notohamiprodjo, Mike
    Herzen, Julia
    SCIENTIFIC REPORTS, 2017, 7
  • [40] Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up
    Anikó Sztrókay
    Julia Herzen
    Sigrid D. Auweter
    Susanne Liebhardt
    Doris Mayr
    Marian Willner
    Dieter Hahn
    Irene Zanette
    Timm Weitkamp
    Karin Hellerhoff
    Franz Pfeiffer
    Maximilian F. Reiser
    Fabian Bamberg
    European Radiology, 2013, 23 : 381 - 387