Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging

被引:11
作者
Velroyen, Astrid [1 ,2 ]
Bech, Martin [1 ,2 ,3 ]
Tapfer, Arne [1 ,2 ]
Yaroshenko, Andre [1 ,2 ]
Mueller, Mark [1 ,2 ]
Paprottka, Philipp [4 ]
Ingrisch, Michael [4 ]
Cyran, Clemens C. [4 ]
Auweter, Sigrid D. [4 ]
Nikolaou, Konstantin [4 ]
Reiser, Maximilian F. [4 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Lehrstuhl Biomed Phys, Dept Phys, Garching, Germany
[2] Tech Univ Munich, Inst Med, Garching, Germany
[3] Lund Univ, Med Radiat Phys, Lund, Sweden
[4] Univ Munich, Hosp Munich, Inst Clin Radiol, Munich, Germany
基金
欧洲研究理事会;
关键词
DIFFERENTIAL PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; NANOPARTICLES; SIGNAL;
D O I
10.1371/journal.pone.0129512
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.
引用
收藏
页数:14
相关论文
共 39 条
[1]  
[Anonymous], 2013, Journal of Biomedical Engineering and Technology, DOI [DOI 10.12691/JBET-1-2-1, 10.12691/jbet-1-2-1]
[2]   Microbubbles as x-ray scattering contrast agents using analyzer-based imaging [J].
Arfelli, F. ;
Rigon, L. ;
Menk, R. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06) :1643-1658
[3]   Multimodality imaging using SPECT/CT and MRI and ligand functionalized 99mTc-labeled magnetic microbubbles [J].
Barrefelt, Asa A. ;
Brismar, Torkel B. ;
Egri, Gabriella ;
Aspelin, Peter ;
Olsson, Annie ;
Oddo, Letizia ;
Margheritelli, Silvia ;
Caidahl, Kenneth ;
Paradossi, Gaio ;
Daehne, Lars ;
Axelsson, Rimma ;
Hassan, Moustapha .
EJNMMI RESEARCH, 2013, 3 :1-14
[4]   In-vivo dark-field and phase-contrast x-ray imaging [J].
Bech, M. ;
Tapfer, A. ;
Velroyen, A. ;
Yaroshenko, A. ;
Pauwels, B. ;
Hostens, J. ;
Bruyndonckx, P. ;
Sasov, A. ;
Pfeiffer, F. .
SCIENTIFIC REPORTS, 2013, 3
[5]   Quantitative x-ray dark-field computed tomography [J].
Bech, M. ;
Bunk, O. ;
Donath, T. ;
Feidenhans'l, R. ;
David, C. ;
Pfeiffer, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5529-5539
[6]   A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging [J].
Bennett, Eric E. ;
Kopace, Rael ;
Stein, Ashley F. ;
Wen, Han .
MEDICAL PHYSICS, 2010, 37 (11) :6047-6054
[7]   Magnetite Nanoparticles Can Be Coupled to Microbubbles to Support Multimodal Imaging [J].
Brismar, Torkel B. ;
Grishenkov, Dmitry ;
Gustafsson, Bjorn ;
Harmark, Johan ;
Barrefelt, Asa ;
Kothapalli, Satya V. V. N. ;
Margheritelli, Silvia ;
Oddo, Letizia ;
Caidahl, Kenneth ;
Hebert, Hans ;
Paradossi, Gaio .
BIOMACROMOLECULES, 2012, 13 (05) :1390-1399
[8]   Stable polymeric microballoons as multifunctional device for biomedical uses: Synthesis and characterization [J].
Cavalieri, F ;
El Hamassi, A ;
Chiessi, E ;
Paradossi, G .
LANGMUIR, 2005, 21 (19) :8758-8764
[9]   Beam hardening effects in grating-based x-ray phase-contrast imaging [J].
Chabior, Michael ;
Donath, Tilman ;
David, Christian ;
Bunk, Oliver ;
Schuster, Manfred ;
Schroer, Christian ;
Pfeiffer, Franz .
MEDICAL PHYSICS, 2011, 38 (03) :1189-1195
[10]   Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometer and a rotating anode x-ray tube: theory and experiments [J].
Chen, Guang-Hong ;
Bevins, Nicholas ;
Zambelli, Joseph ;
Qi, Zhihua .
OPTICS EXPRESS, 2010, 18 (12) :12960-12970