Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging

被引:11
|
作者
Velroyen, Astrid [1 ,2 ]
Bech, Martin [1 ,2 ,3 ]
Tapfer, Arne [1 ,2 ]
Yaroshenko, Andre [1 ,2 ]
Mueller, Mark [1 ,2 ]
Paprottka, Philipp [4 ]
Ingrisch, Michael [4 ]
Cyran, Clemens C. [4 ]
Auweter, Sigrid D. [4 ]
Nikolaou, Konstantin [4 ]
Reiser, Maximilian F. [4 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Lehrstuhl Biomed Phys, Dept Phys, Garching, Germany
[2] Tech Univ Munich, Inst Med, Garching, Germany
[3] Lund Univ, Med Radiat Phys, Lund, Sweden
[4] Univ Munich, Hosp Munich, Inst Clin Radiol, Munich, Germany
来源
PLOS ONE | 2015年 / 10卷 / 07期
基金
欧洲研究理事会;
关键词
DIFFERENTIAL PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; NANOPARTICLES; SIGNAL;
D O I
10.1371/journal.pone.0129512
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.
引用
收藏
页数:14
相关论文
共 47 条
  • [1] Grating-based x-ray dark-field CT for lung cancer diagnosis in mice
    Guo, Peiyuan
    Zhang, Li
    Lu, Jincheng
    Zhang, Huitao
    Zhu, Xiaohua
    Wu, Chengpeng
    Zhan, Xiangwen
    Yin, Hongxia
    Wang, Zhenchang
    Xu, Yan
    Wang, Zhentian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [2] Comparison of contrast-to-noise ratios of transmission and dark-field signal in grating-based X-ray imaging for healthy murine lung tissue
    Schwab, Felix
    Schleede, Simone
    Hahn, Dieter
    Bech, Martin
    Herzen, Julia
    Auweter, Sigrid
    Bamberg, Fabian
    Achterhold, Klaus
    Yildirim, Ali Oe.
    Bohla, Alexander
    Eickelberg, Oliver
    Loewen, Rod
    Gifford, Martin
    Ruth, Ronald
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Pfeiffer, Franz
    Meinel, Felix G.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 236 - 242
  • [3] Nanoparticle Contrast Agents for Dark-Field X-ray Imaging
    Navarrete-Leon, Carlos
    Doherty, Adam
    Strimaite, Margarita
    Bear, Joseph C.
    Olivo, Alessandro
    Endrizzi, Marco
    Patrick, P. Stephen
    NANO LETTERS, 2024, 25 (03) : 1036 - 1042
  • [4] Quantitative wave-optical numerical analysis of the dark-field signal in grating-based X-ray interferometry
    Malecki, A.
    Potdevin, G.
    Pfeiffer, F.
    EPL, 2012, 99 (04)
  • [5] Grating-based X-ray dark-field computed tomography for the characterization of friction stir welds: A feasibility study
    Schaff, Florian
    Bachmann, Andreas
    Zens, Amanda
    Zaeh, Michael F.
    Pfeiffer, Franz
    Herzen, Julia
    MATERIALS CHARACTERIZATION, 2017, 129 : 143 - 148
  • [6] A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging
    Bennett, Eric E.
    Kopace, Rael
    Stein, Ashley F.
    Wen, Han
    MEDICAL PHYSICS, 2010, 37 (11) : 6047 - 6054
  • [7] Correcting Intensity Drift in X-ray Grating-based Phase Contrast Imaging
    Zhang, P.
    Shao, Q.
    Hu, R.
    Wang, S.
    Zan, G.
    Wang, S.
    Bao, Y.
    Wali, F.
    Tian, Y.
    Liu, G.
    Wang, Z.
    Gao, K.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [8] Energy weighting in grating-based x-ray phase-contrast imaging
    Pelzer, Georg
    Weber, Thomas
    Anton, Gisela
    Sune, Rafael Ballabriga
    Bayer, Florian
    Campbell, Michael
    Haas, Wilhelm
    Horn, Florian
    Cudie, Xavi Llopart
    Michel, Norbert
    Mollenbauer, Uwe
    Rieger, Jens
    Ritter, Andre
    Ritter, Ina
    Woelfel, Stefan
    Wong, Winnie S.
    Zang, Andrea
    Michel, Thilo
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [9] Shading Correction for Grating-based Differential Phase Contrast X-ray Imaging
    Kaeppler, Sebastian
    Wandner, Johannes
    Weber, Thomas
    Maier, Andreas
    Anton, Gisela
    Hornegger, Joachim
    Riess, Christian
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [10] Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry
    Yang, Yi