MEASURING PLASMA FERRITIN LEVELS WITH TWO DIFFERENT METHODS: A COMPARISON OF ROCHE COBAS E601 VERSUS ROCHE COBAS C501 (INTEGRATED MODULAR SYSTEM ROCHE COBAS 6000)

被引:9
作者
Ayan, Durmus [1 ]
Soylemez, Sibel [2 ]
机构
[1] Amasya Cent Publ Hlth Lab, Med Biochem, TR-05000 Amasya, Turkey
[2] Gazi Univ, Fac Med, Med Biochem, Ankara, Turkey
关键词
plasma ferritin; electrochemiluminescence; immunoturbidimetric;
D O I
10.2478/jomb-2018-0048
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: The aim of our study is to compare plasma ferritin levels found to be high or low in terms of reference range by means of electrochemiluminescence (ECLIA) and immunoturbidimetric method and to examine whether they can be used interchangeably. Methods: 84 patients with high plasma ferritin level and 153 patients with low ferritin level according to the reference range were included in the study. Plasma samples measured in Cobas e601 device with ECLIA were also measured as immunoturbidimetric Cobas c501 device. For method comparison, CLSI EP-A3 Guideline was used. While the consistency between the methods were specified with Passing-Bablok regression analysis and Spearman correlation analysis, bias error between the methods (bias%) was determined through Bland-Altman analysis. Results: Both high and low plasma ferritin levels measured with Cobas e601 module and determined high in terms of reference range were compared with the results found with cobas c501 module. The difference was found to be statistically significant (p<0.001). According to regression and correlation (for low plasma ferritin levels; r: 0.993, p<0.001, for high plasma ferritin levels; r: 0.966, p<0.001) results, the methods were in consistency with each other. Additionally, while the bias% value was found to be 10.4% for low plasma ferritin levels, it was found to be 12.6% for high ferritin levels. Conclusions: Accordingly, we believe that, comparison with more samples especially in terms of different clinical decision levels is required in order to examine interchangeable use of immunoturbidimetric method in integrated devices and ECLIA.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 14 条
[1]  
[Anonymous], 1985, BRIT J HAEMATOL, V61, P61
[2]   Automated immunoassay methods for ferritin: recovery studies to assess traceability to an international standard [J].
Blackmore, Sheena ;
Hamilton, Malcolm ;
Lee, Anne ;
Worwood, Mark ;
Brierley, Matthew ;
Heath, Alan ;
Thorpe, Susan J. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (10) :1450-1457
[3]  
Carey NR, 2006, USER VERIFICATION PE
[4]  
Dignass A, 2018, INT J CHRONIC DIS, DOI [10.1155/2018/9394060, DOI 10.1155/2018/9394060]
[5]  
Dupuy AM, 2009, CLIN LAB, V55, P207
[6]   Association of different iron deficiency cutoffs with adverse outcomes in chronic kidney disease [J].
Eisenga, Michele F. ;
Nolte, Ilja M. ;
van der Meer, Peter ;
Bakker, Stephan J. L. ;
Gaillard, Carlo A. J. M. .
BMC NEPHROLOGY, 2018, 19
[7]   Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis [J].
Garcia-Casal, Maria N. ;
Pena-Rosas, Juan P. ;
Urrechaga, Eloise ;
Escanero, Jesus F. ;
Huo, Junsheng ;
Martinez, Ricardo X. ;
Lopez-Perez, Lucero .
PLOS ONE, 2018, 13 (05)
[8]  
Ince F.D., 2016, TURK CLIN BIOCH J, V14, P51
[9]   Comparison of four immunoassays to measure serum ferritin concentrations and iron deficiency prevalence among non-pregnant Cambodian women and Congolese children [J].
Karakochuk, Crystal D. ;
Whitfield, Kyly C. ;
Rappaport, Aviva I. ;
Barr, Susan I. ;
Vercauteren, Suzanne M. ;
McLean, Judy ;
Hou, Kroeun ;
Talukder, Aminuzzaman ;
Houghton, Lisa A. ;
Bailey, Karl B. ;
Boy, Erick ;
Green, Timothy J. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (01) :65-72
[10]   Association between serum ferritin and hypertension according to the working type in Korean men: the fifth Korean National Health and nutrition examination survey 2010-2012 [J].
Lee, Dong-Hoon ;
Kang, Seong-Kyu ;
Choi, Won-Jun ;
Kwak, Kyeong Min ;
Kang, Dukyun ;
Lee, Sang Ha ;
Lee, Jun-Hyung .
ANNALS OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2018, 30