Metal-on-Metal Total Hip Arthroplasty: Causes and High Incidence of Early Failure

被引:54
作者
Fabi, David [1 ]
Levine, Brett [2 ]
Paprosky, Wayne [2 ]
Della Valle, Craig [2 ]
Sporer, Scott [3 ]
Klein, Gregg [3 ]
Levine, Harlan [3 ]
Hartzband, Mark [3 ]
机构
[1] San Diego Orthopaed Associates Med Grp, San Diego, CA 92103 USA
[2] Rush Univ, Med Ctr, Chicago, IL 60612 USA
[3] Hartzband Ctr Hip & Knee Replacements, Paramus, NJ USA
关键词
POLYETHYLENE; PSEUDOTUMOR; BEARINGS; DIAMETER;
D O I
10.3928/01477447-20120621-12
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Early failures of metal-on-metal total hip arthroplasty (THA) occur due to aseptic loosening, metal hypersensitivity reactions, pseudotumor formation, and component seizing. The purpose of this study was to investigate the timing, common modes of failure, clinical outcomes, and incidence of metal-on-metal THA revisions. A review was performed of 80 patients who underwent revision of a failed metal-on-metal THA for any reason. The most common reason for metal-on-metal failure was aseptic acetabular loosening, with a rate of 56.25% (45/80 patients). Early failure of metal-on-metal THAs was noted, with 78% of these revisions being performed within 2 years of the index operation and 92.5% within 3 years. Furthermore, 13% of patients experienced significant localized soft tissue reactions. Mean preoperative Harris Hip Score was 42.35 +/- 14.24 and mean postoperative Harris Hip Score was 66.5 +/- 23.2 (range, 9.55-95.4), with an average follow-up of 438 +/- 492 days (range, 40-2141), or 1.2 years. It is imperative that clinicians be cognizant of the fact that the proposed advantages of metal-on-metal THA are not without potential detrimental sequelae. This article proposes an algorithm to aid in diagnosing the etiology of a painful metal-on-metal THA, as well as 2 classification schemes regarding metal-on-metal THA complications to help direct treatment.
引用
收藏
页码:E1009 / E1016
页数:8
相关论文
共 50 条
  • [31] Factors associated with symptomatic pseudotumors following metal-on-metal total hip arthroplasty
    Hasegawa, Masahiro
    Naito, Yohei
    Yamaguchi, Toshio
    Miyazaki, Shinichi
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17 : 1 - 5
  • [32] Serum Metal Ion Concentration: Comparison Between Small and Large Head Metal-on-Metal Total Hip Arthroplasty
    Hallows, Rhett K.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1176 - 1181
  • [33] "Asymptomatic" Pseudotumors After Metal-on-Metal Hip Resurfacing Arthroplasty
    Kwon, Young-Min
    Ostlere, Simon J.
    McLardy-Smith, Peter
    Athanasou, Nicholas A.
    Gill, Harinderjit S.
    Murray, David W.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04) : 511 - 518
  • [34] High Complication Rate After Revision of Large-head Metal-on-metal Total Hip Arthroplasty
    Munro, Jacob T.
    Masri, Bassam A.
    Duncan, Clive P.
    Garbuz, Donald S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) : 523 - 528
  • [35] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08) : 2574 - 2579
  • [36] Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty
    Hasegawa, Masahiro
    Iino, Takahiro
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [37] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Pomeroy, Eoghan
    Macnamara, Fergal
    Murphy, Evelyn
    McGoldrick, Niall
    Mahapatra, Anant
    Awan, Nasir
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 149 - 153
  • [38] Metal Ion Release With Large-Diameter Metal-on-Metal Hip Arthroplasty
    Vendittoli, Pascal-Andre
    Amzica, Traian
    Roy, Alain G.
    Lusignan, Daniel
    Girard, Julien
    Lavigne, Martin
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02) : 282 - 288
  • [39] Large-Diameter Modular Metal-on-Metal Total Hip Arthroplasty Incidence of Revision for Adverse Reaction to Metallic Debris
    Barrett, William P.
    Kindsfater, Kirk A.
    Lesko, James P.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 976 - 983
  • [40] Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip Arthroplasty
    Hasegawa, Masahiro
    Yoshida, Kakunoshin
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 990 - 996