True Reproducibility of UltraSound Techniques (TRUST): systematic review of reliability studies in obstetrics and gynecology

被引:48
作者
Coelho Neto, M. A. [1 ]
Roncato, P. [1 ,2 ]
Nastri, C. O. [1 ]
Martins, W. P. [1 ]
机构
[1] Univ Sao Paulo DGO FMRP USP, Ribeirao Preto Med Sch, Dept Obstet & Gynecol, Ribeirao Preto, Brazil
[2] Sch Hlth Technol Ultrasonog Sch Ribeirao Preto FA, Ribeirao Preto, Brazil
关键词
gynecology; obstetrics; reproducibility of results; ultrasound; NUCHAL TRANSLUCENCY THICKNESS; COMPUTER-AIDED ANALYSIS; ANTRAL FOLLICLE COUNTS; TRANSVAGINAL 3-DIMENSIONAL ULTRASONOGRAPHY; SPATIOTEMPORAL IMAGE CORRELATION; POWER DOPPLER ANGIOGRAPHY; LOWER UTERINE SEGMENT; FETAL HEAD DESCENT; ENDOMETRIAL VOLUME MEASUREMENTS; INTRACARDIAC ECHOGENIC FOCI;
D O I
10.1002/uog.14654
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To examine the quality of methods used and the accuracy of the interpretation of agreement in existing studies that examine the reliability of ultrasound measurements and judgments in obstetrics and gynecology. Methods A systematic search of MEDLINE was performed on 25 March 2014, looking for studies that examined the reliability of ultrasound measurements and judgments in obstetrics and gynecology with evaluation of concordance (CCC) or intraclass (ICC) correlation coefficients or kappa as a main objective. Results Seven hundred and thirty-three records were examined on the basis of their title and abstract, of which 141 full-text articles were examined completely for eligibility. We excluded 2(studies because they did not report CCC/ICC/kappa, leaving 112 studies that were included in our analysis. Two studies reported both ICC and kappa and were counted twice, therefore, the number used as the denominator in the analyses was 114. Only 16/114 (14.0%) studies were considered to be well designed (independent acquisition and blinded analysis) and to have interpreted the results properly. Most errors occurring in the studies are likely to overestimate the reliability of the method examined. Conclusions The vast majority of published studies examined had important flaws in design, interpretation and/or reporting. Such limitations are important to identify as they might create false confidence in the existing measurements and judgments, jeopardizing clinical practice and future research. Specific guidelines aimed at improving the quality of reproducibility studies that examine ultrasound methods should be encouraged. Copyright (C) 2014 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 151 条
[1]   Intra- and interoperator reliability of manual and semi-automated measurement of fetal nuchal translucency by sonographers with different levels of experience [J].
Abele, H. ;
Hoopmann, M. ;
Wright, D. ;
Hoffmann-Poell, B. ;
Huettelmaier, M. ;
Pintoffl, K. ;
Wallwiener, D. ;
Kagan, K. O. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) :417-422
[2]   Intrapartum sonography to determine fetal occipital position: interobserver agreement [J].
Akmal, S ;
Tsoi, E ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (04) :421-424
[3]   Endometrial volume and vascularity measurements by transvaginal 3-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria -: An interobserver reproducibility study [J].
Alcázar, JL ;
Mercé, LT ;
Manero, MG ;
Bau, S ;
López-García, G .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (08) :1091-1098
[4]   In vivo validation of the time domain velocity measurement technique of blood flow in human fetuses [J].
Alcazar, JL ;
Laparte, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) :9-13
[5]   Three-dimensional versus two-dimensional ultrasound measurement of follicular volume: Are they comparable? [J].
Ahmed Amer ;
Mohamad Eid Hammadeh ;
Mohamed Kolkailah ;
Abdel-Al Ghandour .
Archives of Gynecology and Obstetrics, 2003, 268 (3) :155-157
[6]   An evaluation of the inter-observer and intra-observer variability of the ultrasound diagnosis of polycystic ovaries [J].
Amer, SAKS ;
Li, TC ;
Bygrave, C ;
Sprigg, A ;
Saravelos, H ;
Cooke, ID .
HUMAN REPRODUCTION, 2002, 17 (06) :1616-1622
[7]   Quantification of power Doppler energy and its future potential [J].
Amso, NN ;
Watermeyer, SR ;
Pugh, N ;
O'Brien, S ;
D'Angelo, A .
FERTILITY AND STERILITY, 2001, 76 (03) :583-587
[8]   Comparison of two- and three-dimensional ultrasonography in lung volume measurement of normal fetuses [J].
Araujo, Edward, Jr. ;
Machado Nardozza, Luciano Marcondes ;
Pires, Claudio Rodrigues ;
Guimaraes Filho, Helio Antonio ;
Moron, Antonio Fernandes .
JOURNAL OF PERINATAL MEDICINE, 2007, 35 (05) :415-421
[9]   Delineation of vertebral area on the coronal plane using three-dimensional ultrasonography advanced volume contrast imaging (VCI) Omni view: intrarater reliability and agreement using standard mouse, high definition mouse, and pen-tablet [J].
Araujo Junior, Edward ;
Martinez, Luis Henrique ;
Simioni, Christiane ;
Martins, Wellington P. ;
Nardozza, Luciano M. ;
Moron, Antonio F. .
JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 (09) :1818-1821
[10]   Comparison of automated and manual follicle monitoring in an unrestricted population of 100 women undergoing controlled ovarian stimulation for IVF [J].
Ata, Baris ;
Seyhan, Ayse ;
Reinblatt, Shauna Leigh ;
Shalom-Paz, Einat ;
Krishnamurthy, Srinivasan ;
Tan, Seang Lin .
HUMAN REPRODUCTION, 2011, 26 (01) :127-133