Development of a novel potentiometric titration method for determination of polypropylene degradation

被引:2
作者
Manabe, N
Kawamura, K
Ishikawa, M
Suzuki, S
Liu, BP
Terano, M
Nakatani, H
机构
[1] Kanazawa Inst Technol, Dept Bioengn & Chem, Nonoichi, Ishikawa 9218501, Japan
[2] Sumitomo Wiring Syst Co Ltd, Res & Evaluat Ctr, Suzuka, Mie 5138631, Japan
[3] Japan Adv Inst Sci & Technol, Sch Mat Sci, Nomi, Ishikawa 9231292, Japan
关键词
potentiometric titration method; HPO; polypropylene impact copolymer; thermal oxidative degradation;
D O I
10.1016/j.polymertesting.2005.08.002
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study, a novel potentiometric titration of hydroperoxide in degraded polypropylene (PP) is proposed. This titration is quite sensitive compared with the conventional ones such as UV and manual titrations, and its detection limit was about 2 meq/kg. The sensitivity was equal to that of molecular weight measurement by GPC for the degraded PP and, in addition, the volatilization behavior of the hydroperoxide could be detected. This titration was found to be very effective for the determination of PP degradation. (c) 2005 Elsevier Ltd. All rights reserved.