Resolution-effective diameters for asymmetric-knife-edge pinhole collimators

被引:19
作者
Accorsi, R [1 ]
Metzler, SD
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
collimator; image resolution; photon penetration; pinhole; single photon emission computed tomography; small-animal imaging; SPECT;
D O I
10.1109/TMI.2005.857229
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The effects of penetration are included in the formulas for the prediction of the resolution of pinhole collimators through the use of effective diameters. Expressions of the resolution-effective diameter for pinholes with a double-knife-edge (DKE) profile are available in the literature. In this paper the expressions applicable to asymmetric-knife-edge (AKE) profiles, which include the important case of the single-knife-edge (SKE), are presented. Results indicate that the simplest methods that are still accurate in the calculation of DKE effective diameters do not produce in general formulas with similar accuracy for AKE profiles, due to increased susceptibility to penetration. Especially at high energy (365 keV) for the SKE case more advanced formulas are necessary and were, therefore, derived.
引用
收藏
页码:1637 / 1646
页数:10
相关论文
共 21 条
[1]   Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) :750-763
[2]   Small animal imaging with high resolution single photon emission tomography [J].
Acton, PD ;
Kung, HF .
NUCLEAR MEDICINE AND BIOLOGY, 2003, 30 (08) :889-895
[3]   Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography [J].
Acton, PD ;
Choi, SR ;
Plössl, K ;
Kung, HF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (05) :691-698
[4]  
Anger H. O., 1967, INSTRUM NUCL, V1, P485
[5]   Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholes [J].
Beekman, FJ ;
McElroy, DP ;
Berger, F ;
Gambhir, SS ;
Hoffman, EJ ;
Cherry, SR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :933-938
[6]  
Berger M.J., XCOM: Photon Cross -Sections Database
[7]   Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography [J].
Booij, J ;
de Bruin, K ;
Habraken, JBA ;
Voorn, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (09) :1221-1224
[8]  
ISHIZU K, 1995, J NUCL MED, V36, P2282
[9]   PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT [J].
JASZCZAK, RJ ;
LI, JY ;
WANG, HL ;
ZALUTSKY, MR ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :425-437
[10]   PERFORMANCE OF A GAMMA CAMERA FOR VISUALIZATION OF RADIOACTIVE ISOTOPES IN VIVO [J].
MALLARD, JR ;
MYERS, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1963, 8 (1-4) :165-&