A simple, anatomically based correction to the conventional ankle joint center

被引:19
作者
Bruening, Dustin A. [1 ,2 ]
Crewe, Ashlie N. [3 ]
Buczek, Frank L. [1 ,4 ]
机构
[1] Shriners Hosp Children Erie, Erie, PA 16509 USA
[2] Univ Delaware, Hlth Nutr & Exercise Sci Dept, Newark, DE USA
[3] Gannon Univ, Phys Therapy Dept, Erie, PA USA
[4] NIOSH, Morgantown, WV USA
关键词
Ankle joint center; Ankle axes; Joint translation; Six-degree-of-freedom modeling; Gait analysis;
D O I
10.1016/j.clinbiomech.2008.08.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Conventional motion analysis studies define the ankle joint center as the midpoint between the most medial and lateral aspects of the malleoli, yet research points toward a more distal joint center location. The purpose of this study was to develop and evaluate an anatomically based correction that would move the conventional ankle joint center to a more accurate location. Methods. Lower extremity radiographs from 30 pediatric patients were analyzed retrospectively. An offset between the conventional and more accurate ankle joint centers was measured and correlated to other common anatomical measures based on conventional skin mounted marker positions. The best correlated measure was used to define a simple correction factor, which was subsequently evaluated by its effect on six degree-of-freedom ankle joint translations during normal gait (n = 8). Findings. Shank length was found to have the highest bivariate linear correlation (r = 0.89) with the offset. Adjusting the ankle joint center using a percentage of shank length (2.7%) was also as accurate as the regression equation in predicting offset (mean error 0.6 mm, or 6% offset). Adjusting the ankle joint center using this simple percentage resulted in a 25% reduction in mean ankle joint translations during normal gait. Interpretation. The accuracy of the ankle joint center can be increased through a simple, anatomically based correction. This correction may prove beneficial in some kinematic and kinetic applications requiring increased anatomical fidelity. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1299 / 1302
页数:4
相关论文
共 15 条
[11]   Effects of hip joint centre mislocation on gait analysis results [J].
Stagni, R ;
Leardini, A ;
Cappozzo, A ;
Benedetti, MG ;
Cappello, A .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1479-1487
[12]   Role of passive structures in the mobility and stability of the human subtalar joint: A literature review [J].
Stagni, R ;
Leardini, A ;
O'Connor, JJ ;
Giannini, S .
FOOT & ANKLE INTERNATIONAL, 2003, 24 (05) :402-409
[13]  
Urist M.R., 1980, FUNDAMENTAL CLIN BON
[14]  
Walker MR, 2008, BIOMED ENG SER, P489
[15]   ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part 1: ankle, hip, and spine [J].
Wu, G ;
Siegler, S ;
Allard, P ;
Kirtley, C ;
Leardini, A ;
Rosenbaum, D ;
Whittle, M ;
D'Lima, DD ;
Cristofolini, L ;
Witte, H ;
Schmid, O ;
Stokes, H .
JOURNAL OF BIOMECHANICS, 2002, 35 (04) :543-548