Detection of γ-rays with a 3.5 1 liquid xenon ionization chamber triggered by the primary scintillation light

被引:10
作者
Aprile, E [1 ]
Bolotnikov, A [1 ]
Chen, DL [1 ]
Muhkerjee, R [1 ]
Xu, F [1 ]
机构
[1] Columbia Univ, Columbia Astrophys Lab, New York, NY 10027 USA
基金
美国国家航空航天局;
关键词
D O I
10.1016/S0168-9002(01)01204-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A gridded ionization chamber with a drift length of 4.5 cm and a total volume of 3.5 1, was operated with high-purity liquid xenon and extensively tested with gamma-rays from Cs-137, Na-22 and Co-60 radioactive sources. An electron lifetime in excess of I ins was inferred from two independent measurements. The electric Field dependence of the collected charge and energy resolution was studied in the range 0.1-4 kV/cm, for different gamma-ray energies, With an electric field of 4 kV/cm, the spectral performance of the detector is consistent with an energy resolution of 5.9% at 1 MeV, scaling with energy as E-0.5 The chamber was also used to detect the primary scintillation light produced by gamma-ray interactions in liquid xenon. The light signal was successfully used to trigger the acquisition of the charge signal with a FADC readout. A trigger efficiency of similar to85% was measured at 662 keV. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:636 / 650
页数:15
相关论文
共 19 条
[1]   DEVELOPMENT OF LIQUID XENON DETECTORS FOR GAMMA-RAY ASTRONOMY [J].
APRILE, E ;
SUZUKI, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :311-315
[2]   MEASUREMENTS OF THE LIFETIME OF CONDUCTION ELECTRONS IN LIQUID XENON [J].
APRILE, E ;
MUKHERJEE, R ;
SUZUKI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02) :343-350
[3]   IONIZATION OF LIQUID XENON BY AM-241 AND PO-210 ALPHA-PARTICLES [J].
APRILE, E ;
MUKHERJEE, R ;
SUZUKI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (01) :119-125
[4]   A STUDY OF THE SCINTILLATION LIGHT-INDUCED IN LIQUID XENON BY ELECTRONS AND ALPHA-PARTICLES [J].
APRILE, E ;
MUKHERJEE, R ;
SUZUKI, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :553-558
[5]   The liquid xenon gamma-ray imaging telescope (LXeGRIT) for medium energy astrophysics [J].
Aprile, E ;
Egorov, V ;
Xu, F ;
Chupp, EL ;
Dunphy, PP ;
Doke, T ;
Kikuchi, J ;
Fishman, GJ ;
Pendleton, G ;
Masuda, K ;
Kashiwagi, T .
GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 :337-348
[6]   The electronics read out and data acquisition system for a liquid xenon time projection chamber as a balloon-borne Compton telescope [J].
Aprile, E ;
Egorov, V ;
Giboni, KL ;
Kozu, T ;
Xu, F ;
Doke, T ;
Kikuchi, J ;
Kashiwagi, T ;
Fishman, GJ ;
Rehage, R ;
Trice, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (2-3) :425-436
[7]   PERFORMANCE OF A LIQUID XENON IONIZATION-CHAMBER IRRADIATED WITH ELECTRONS AND GAMMA-RAYS [J].
APRILE, E ;
MUKHERJEE, R ;
SUZUKI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :177-185
[8]   A MONTE-CARLO ANALYSIS OF THE LIQUID XENON TPC AS GAMMA-RAY TELESCOPE [J].
APRILE, E ;
BOLOTNIKOV, A ;
CHEN, D ;
MUKHERJEE, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (01) :216-221
[9]  
APRILE E, 1989, SPIE C P, V1159, P295
[10]   EFFECT OF AN ELECTRIC-FIELD ON ELECTRON-ATTACHMENT TO SF6, N2O, AND O-2 IN LIQUID ARGON AND XENON [J].
BAKALE, G ;
SOWADA, U ;
SCHMIDT, WF .
JOURNAL OF PHYSICAL CHEMISTRY, 1976, 80 (23) :2556-2559