Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

被引:3
|
作者
Ferrer-Blasco, Teresa [1 ]
Garcia-Lazaro, Santiago [1 ]
Albarran-Diego, Cesar [1 ]
Perez-Vives, Cari [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, E-46100 Burjassot, Valencia, Spain
关键词
Lens implantation; intraocular; Lens cristalline/surgery; Myopia/surgery; Hyperopia/physiopathology; Phacoemulsification; Visual acuity; VISUAL FUNCTION; IMPLANTATION; DISTANCE; OUTCOMES; QUALITY; DISCRIMINATION; PERFORMANCE; CLEAR; EYES;
D O I
10.1590/S0004-27492013000200002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof (R) ReSTOR (R) (SN6AD3 model) intraocular lens (IOL). Methods: Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m(2)) before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. Results: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002). Conclusions: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [31] Visual function after implantation of a diffractive aspheric trifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega Cueto, Luis
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 405 - 411
  • [32] Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study
    Alió, JL
    Tavolato, M
    De la Hoz, F
    Claramonte, P
    Rodríguez-Prats, JL
    Galal, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12): : 2494 - 2503
  • [33] Distance and near contrast sensitivity function after multifocal intraocular lens implantation
    Montés-Micó, R
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 703 - 711
  • [34] Quality of vision after bilateral multifocal intraocular lens implantation in pregeriatric Hispanic population, after refractive lens exchange
    Alberto Nava, Jose
    Rubi Morales-Mancillas, Nallely
    Valdez, Jorge E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [35] Comparative analysis of the visual and refractive outcomes of an aspheric diffractive intraocular lens with and without toricity
    Frieling-Reuss, Elisabeth H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1485 - 1493
  • [36] Contrast Sensitivity and Patient Reported Outcomes After Bilateral Implantation of a Bi-Aspheric Hydrophobic Trifocal Diffractive Intraocular Lens
    Tana-Rivero, Pedro
    Orts-Vila, Paz
    Aguilar-Corcoles, Salvador
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 247 - 258
  • [37] Combining Zonal Refractive and Diffractive Aspheric Multifocal Intraocular Lenses
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Javaloy, Jaime
    Sakla, Hani F.
    Cervino, Alejandro
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) : 174 - 181
  • [38] Modulation transfer function in a diffractive bifocal and refractive multifocal intraocular lens.
    Pieh, S
    Marvan, P
    Lackner, B
    Hanselmayer, G
    Schmidinger, G
    Leitgeb, R
    Sticker, M
    Hitzenberger, CK
    Fercher, AF
    Skorpik, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S9 - S9
  • [39] Threshold limit of postoperative astigmatism for patient satisfaction after refractive lens exchange and multifocal intraocular lens implantation
    McNeely, Richard N.
    Pazo, Eric
    Millar, Zack
    Richoz, Olivier
    Nesbit, Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1126 - 1134
  • [40] Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lens
    Weghaupt, H
    Pieh, S
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05): : 663 - 665