Dual-Readout Immunochromatographic Assay by Utilizing MnO2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

被引:99
作者
Ouyang, Hui [1 ,2 ]
Lu, Qian [1 ]
Wang, Wenwen [2 ]
Song, Yang [1 ]
Tu, Xinman [1 ]
Zhu, Chengzhou [1 ]
Smith, Jordan N. [3 ]
Du, Dan [1 ]
Fu, Zhifeng [2 ]
Lin, Yuehe [1 ]
机构
[1] Washington State Univ, Sch Mech & Mat Engn, Pullman, WA 99164 USA
[2] Southwest Univ, Coll Pharmaceut Sci, Minist Educ, Key Lab Luminescence & Real Time Analyt Chem, Chongqing 400716, Peoples R China
[3] Pacific Northwest Natl Lab, Hlth Impacts & Exposure Sci, Richland, WA 99352 USA
关键词
GRAPHENE OXIDE; ORGANOPHOSPHORUS PESTICIDES; CATALYTIC-ACTIVITY; COLORIMETRIC ASSAY; PEROXIDASE; NANOPARTICLES; ENZYME; FE3O4; BIOSENSORS; NANOSHEETS;
D O I
10.1021/acs.analchem.7b05247
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and used as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10 min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen in the test strip, resulting in the captured MnO2 NFs on test line. The captured MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Due to the very slight colorimetric difference of chlorpyrifos at trace concentrations, the semiquantitative readout by naked eyes could not meet the demand of quantitative analysis. MnO2 NFs showed a significant effect on the luminol-H2O2 chemiluminescent (CL) system, and the CL signal driven by MnO2 NFs were used to detect the trace concentration of chlorpyrifos quantitatively. 1,3-Diphenylisobenzofuran quenching studies and TMB-H2O2 coloration assays were conducted for studying the enhancing mechanism of MnO2 NFs, which was based on the oxidant activity to decompose H2O2 for forming reactive oxygen species. Under optimal conditions, the linear range of chlorpyrifos was 0.1-50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring and food safety.
引用
收藏
页码:5147 / 5152
页数:6
相关论文
共 39 条
[1]   Enhanced catalytic activity of gold nanoparticle-carbon nanotube hybrids for influenza virus detection [J].
Ahmed, Syed Rahin ;
Kim, Jeonghyo ;
Suzuki, Tetsuro ;
Lee, Jaebeom ;
Park, Enoch Y. .
BIOSENSORS & BIOELECTRONICS, 2016, 85 :503-508
[2]   Organophosphate vapor detection on gold electrodes using peptide nanotubes [J].
Baker, Peter A. ;
Goltz, Mark N. ;
Schrand, Amanda M. ;
Yoon, Do Young ;
Kim, Dong-Shik .
BIOSENSORS & BIOELECTRONICS, 2014, 61 :119-123
[3]   Development of an ion-pair liquid chromatography-high resolution mass spectrometry method for determination of organophosphate pesticide metabolites in large-scale biomonitoring studies [J].
Cequier, Enrique ;
Sakhi, Amrit Kaur ;
Haug, Line Smastuen ;
Thomsen, Cathrine .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1454 :32-41
[4]   Break-up of Two-Dimensional MnO2 Nanosheets Promotes Ultrasensitive pH-Triggered Theranostics of Cancer [J].
Chen, Yu ;
Ye, Delai ;
Wu, Meiying ;
Chen, Hangrong ;
Zhang, Linlin ;
Shi, Jianlin ;
Wang, Lianzhou .
ADVANCED MATERIALS, 2014, 26 (41) :7019-+
[5]   Cu-Ag bimetallic nanoparticles on reduced graphene oxide nanosheets as peroxidase mimic for glucose and ascorbic acid detection [J].
Darabdhara, Gitashree ;
Sharma, Bhagyasmeeta ;
Das, Manash R. ;
Boukherroub, Rabah ;
Szunerits, Sabine .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 :842-851
[6]   Chemiluminescence Switching on Peroxidase-Like Fe3O4 Nanoparticles for Selective Detection and Simultaneous Determination of Various Pesticides [J].
Guan, Guijian ;
Yang, Liang ;
Mei, Qingsong ;
Zhang, Kui ;
Zhang, Zhongping ;
Han, Ming-Yong .
ANALYTICAL CHEMISTRY, 2012, 84 (21) :9492-9497
[7]   Biosensors and their applications in detection of organophosphorus pesticides in the environment [J].
Hassani, Shokoufeh ;
Momtaz, Saeideh ;
Vakhshiteh, Faezeh ;
Maghsoudi, Armin Salek ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Abdollahi, Mohammad .
ARCHIVES OF TOXICOLOGY, 2017, 91 (01) :109-130
[8]   Zirconium(IV) functionalized magnetic nanocomposites for extraction of organophosphorus pesticides from environmental water samples [J].
Jiang, Li ;
Huang, Tengjun ;
Feng, Shun ;
Wang, Jide .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1456 :49-57
[9]   Detection of p53 Protein Based on Mesoporous Pt-Pd Nanoparticles with Enhanced Peroxidase-like Catalysis [J].
Jiang, Tao ;
Song, Yang ;
Du, Dan ;
Liu, Xiangtao ;
Lin, Yuehe .
ACS SENSORS, 2016, 1 (06) :717-724
[10]   Sensitive detection of Escherichia coli O157:H7 using Pt-Au bimetal nanoparticles with peroxidase-like amplification [J].
Jiang, Tao ;
Song, Yang ;
Wei, Tianxiang ;
Li, He ;
Du, Dan ;
Zhu, Mei-Jun ;
Lin, Yuehe .
BIOSENSORS & BIOELECTRONICS, 2016, 77 :687-694