Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data

被引:25
作者
Rank, Christopher M. [1 ]
Heusser, Thorsten [1 ]
Wetscherek, Andreas [1 ,2 ,3 ]
Freitag, Martin T. [4 ]
Sedlaczek, Oliver [4 ]
Schlemmer, Heinz-Peter [4 ]
Kachelriess, Marc [1 ]
机构
[1] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Inst Canc Res, Joint Dept Phys, 123 Old Brompton Rd, London SW7 3RP, England
[3] Royal Marsden NHS Fdn Trust, 123 Old Brompton Rd, London SW7 3RP, England
[4] German Canc Res Ctr, Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
PET/MR; motion compensation; respiratory motion; radial acquisition; high undersampling; POSITRON-EMISSION-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LUNG-CANCER; ONCOLOGY APPLICATIONS; SCANNER; MODEL; CT; ATTENUATION; THERAPY;
D O I
10.1118/1.4966128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Positron emission tomography (PET) of the thorax region is impaired by respiratory patient motion. To account for motion, the authors propose a new method for PET/magnetic resonance (MR) respiratory motion compensation (MoCo), which uses highly undersampled MR data with acquisition times as short as 1 min/bed. Methods: The proposed PET/MR MoCo method (4D jMoCo PET) uses radial MR data to estimate the respiratory patient motion employing MR joint motion estimation and image reconstruction with temporal median filtering. Resulting motion vector fields are incorporated into the system matrix of the PET reconstruction. The proposed approach is evaluated for the thorax region utilizing a PET/MR simulation with 1 min MR acquisition time and simultaneous PET/MR measurements of six patients with MR acquisition times of 1 and 5 min and radial undersampling factors of 11.2 and 2.2, respectively. Reconstruction results are compared to 3D PET, 4D gated PET and a standard MoCo method (4D sMoCo PET), which performs iterative image reconstruction and motion estimation sequentially. Quantitative analysis comprises the parameters SUVmean, SUVmax, full width at half-maximum/lesion volume, contrast and signal-to-noise ratio. Results: For simulated PET data, our quantitative analysis shows that the proposed 4D jMoCo PET approach with temporal filtering achieves the best quantification accuracy of all tested reconstruction methods with a mean absolute deviation of 2.3% when compared to the ground truth. For measured PET patient data, the mean absolute deviation of 4D jMoCo PET using a 1 min MR acquisition for motion estimation is 2.1% relative to the 5 min MR acquisition. This demonstrates a robust behavior even in case of strong undersampling at MR acquisition times as short as 1 min. In contrast, 4D sMoCo PET shows considerable reduction of quantification accuracy for the 1 min MR acquisition time. Relative to 3D PET, the proposed 4D jMoCo PET approach with temporal filtering yields an average increase of SUVmean, SUVmax, and contrast of 29.9% and 13.8% for simulated and measured PET data, respectively. Conclusions: Employing artifact-robust motion estimation enables PET/MR respiratory MoCo with MR acquisition times as short as 1 min/bed improving PET image quality and quantification accuracy. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:6234 / 6245
页数:12
相关论文
共 56 条
  • [1] Lung MRI using an MR-Compatible active breathing control (MR-ABC)
    Arnold, Johannes F. T.
    Moerchel, Philipp
    Glaser, Eckard
    Pracht, Eberhard D.
    Jakob, Peter M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1092 - 1098
  • [2] Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy
    Brehm, Marcus
    Paysan, Pascal
    Oelhafen, Markus
    Kunz, Patrik
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2012, 39 (12) : 7603 - 7618
  • [3] Nonrigid Motion Modeling of the Liver From 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI
    Buerger, C.
    Clough, R. E.
    King, A. P.
    Schaeffter, T.
    Prieto, C.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 805 - 815
  • [4] List Mode-Driven Cardiac and Respiratory Gating in PET
    Buether, Florian
    Dawood, Mohammad
    Stegger, Lars
    Wuebbeling, Frank
    Schaefers, Michael
    Schober, Otmar
    Schaefers, Klaus P.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) : 674 - 681
  • [5] Motion Correction Options in PET/MRI
    Catana, Ciprian
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (03) : 212 - 223
  • [6] MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner
    Catana, Ciprian
    Benner, Thomas
    van der Kouwe, Andre
    Byars, Larry
    Hamm, Michael
    Chonde, Daniel B.
    Michel, Christian J.
    El Fakhri, Georges
    Schmand, Matthias
    Sorensen, Gregory
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (01) : 154 - 161
  • [7] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [8] Lung motion correction on respiratory gated 3-D PET/CT images
    Dawood, M
    Lang, N
    Jiang, XY
    Schäfers, KP
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) : 476 - 485
  • [9] Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes
    Dawood, Mohammad
    Buether, Florian
    Lang, Norbert
    Schober, Otmar
    Schaefers, Klaus P.
    [J]. MEDICAL PHYSICS, 2007, 34 (07) : 3067 - 3076
  • [10] Delso G, 2011, J NUCL MED, V52, P1914, DOI 10.2967/jnumed.111.092726