Technique and Considerations in the Use of 4x1 Ring High-definition Transcranial Direct Current Stimulation (HD-tDCS)

被引:208
作者
Villamar, Mauricio F. [1 ,2 ,3 ]
Volz, Magdalena Sarah [1 ,2 ,4 ]
Bikson, Marom [5 ]
Datta, Abhishek [1 ,2 ,5 ]
DaSilva, Alexandre F. [6 ]
Fregni, Felipe [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Spaulding Rehabil Hosp, Dept Phys Med & Rehabil,Lab Neuromodulat, Cambridge, MA 02138 USA
[2] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Cambridge, MA 02138 USA
[3] Pontifical Catholic Univ Ecuador, Sch Med, Quito, Ecuador
[4] Charite Univ Med Berlin, Berlin, Germany
[5] CUNY City Coll, New York, NY 10031 USA
[6] Univ Michigan, Sch Dent, Ann Arbor, MI 48109 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2013年 / 77期
关键词
Medicine; Issue; 77; Neurobiology; Neuroscience; Physiology; Anatomy; Biomedical Engineering; Biophysics; Neurophysiology; Nervous System Diseases; Diagnosis; Therapeutics; Anesthesia and Analgesia; Investigative Techniques; Equipment and Supplies; Mental; Disorders; Transcranial direct current stimulation; tDCS; High-definition transcranial direct current stimulation; HD-tDCS; Electrical brain stimulation; Transcranial electrical stimulation (tES); Noninvasive Brain Stimulation; Neuromodulation; non-invasive; brain; stimulation; clinical techniques; DC STIMULATION; FEM;
D O I
10.3791/50309
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
High-definition transcranial direct current stimulation (HD-tDCS) has recently been developed as a noninvasive brain stimulation approach that increases the accuracy of current delivery to the brain by using arrays of smaller " high-definition" electrodes, instead of the larger padelectrodes of conventional tDCS. Targeting is achieved by energizing electrodes placed in predetermined configurations. One of these is the 4x1ring configuration. In this approach, a center ring electrode (anode or cathode) overlying the target cortical region is surrounded by four return electrodes, which help circumscribe the area of stimulation. Delivery of 4x1-ring HD-tDCS is capable of inducing significant neurophysiological and clinical effects in both healthy subjects and patients. Furthermore, its tolerability is supported by studies using intensities as high as 2.0 milliamperes for up to twenty minutes. Even though 4x1 HD-tDCS is simple to perform, correct electrode positioning is important in order to accurately stimulate target cortical regions and exert its neuromodulatory effects. The use of electrodes and hardware that have specifically been tested for HD-tDCS is critical for safety and tolerability. Given that most published studies on 4x1 HD-tDCS have targeted the primary motor cortex (M1), particularly for pain-related outcomes, the purpose of this article is to systematically describe its use for M1 stimulation, as well as the considerations to be taken for safe and effective stimulation. However, the methods outlined here can be adapted for other HD-tDCS configurations and cortical targets.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] [Anonymous], BRAIN STIMUL
  • [2] Towards unravelling task-related modulations of neuroplastic changes induced in the human motor cortex
    Antal, Andrea
    Terney, Daniella
    Poreisz, Csaba
    Paulus, Walter
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 2007, 26 (09) : 2687 - 2691
  • [3] Imaging artifacts induced by electrical stimulation during conventional fMRI of the brain
    Antal, Andrea
    Bikson, Marom
    Datta, Abhishek
    Lafon, Belen
    Dechent, Peter
    Parra, Lucas C.
    Paulus, Walter
    [J]. NEUROIMAGE, 2014, 85 : 1040 - 1047
  • [4] A Pilot Study of the Tolerability and Effects of High-Definition Transcranial Direct Current Stimulation (HD-tDCS) on Pain Perception
    Borckardt, Jeffrey J.
    Bikson, Marom
    Frohman, Heather
    Reeves, Scott T.
    Datta, Abhishek
    Bansal, Varun
    Madan, Alok
    Barth, Kelly
    George, Mark S.
    [J]. JOURNAL OF PAIN, 2012, 13 (02) : 112 - 120
  • [5] A systematic review on reporting and assessment of adverse effects associated with transcranial direct current stimulation
    Brunoni, Andre Russowsky
    Amadera, Joao
    Berbel, Bruna
    Volz, Magdalena Sarah
    Rizzerio, Brenno Gomes
    Fregni, Felipe
    [J]. INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2011, 14 (08) : 1133 - 1145
  • [6] Caparelli-Daquer EM, 2012, IEEE ENG MED BIO, P735, DOI 10.1109/EMBC.2012.6346036
  • [7] Electrode Positioning and Montage in Transcranial Direct Current Stimulation
    DaSilva, Alexandre F.
    Volz, Magdalena Sarah
    Bikson, Marom
    Fregni, Felipe
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (51):
  • [8] tDCS-Induced Analgesia and Electrical Fields in Pain-Related Neural Networks in Chronic Migraine
    DaSilva, Alexandre F.
    Mendonca, Mariana E.
    Zaghi, Soroush
    Lopes, Mariana
    DosSantos, Marcos Fabio
    Spierings, Egilius L.
    Bajwa, Zahid
    Datta, Abhishek
    Bikson, Marom
    Fregni, Felipe
    [J]. HEADACHE, 2012, 52 (08): : 1283 - 1295
  • [9] Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
    Datta, Abhishek
    Elwassif, Maged
    Battaglia, Fortunato
    Bikson, Marom
    [J]. JOURNAL OF NEURAL ENGINEERING, 2008, 5 (02) : 163 - 174
  • [10] Datta Abhishek, 2012, Front Psychiatry, V3, P91, DOI 10.3389/fpsyt.2012.00091