Immunosensor with fluid control mechanism for salivary cortisol analysis

被引:69
作者
Yamaguchi, Masaki [1 ]
Matsuda, Yohei [1 ]
Sasaki, Shohei [1 ]
Sasaki, Makoto [1 ]
Kadoma, Yoshihiro [2 ]
Imai, Yoshikatsu [3 ]
Niwa, Daisuke [3 ]
Shetty, Vivek [4 ]
机构
[1] Iwate Univ, Grad Sch Engn, Biomed Engn & Robot Lab, Morioka, Iwate 0208551, Japan
[2] Iwate Univ, Grad Sch Engn, Dept Frontier Mat & Funct Engn, Morioka, Iwate 0208551, Japan
[3] Rohm Co Ltd, Res & Dev Headquarters, Nano Bion R&D Ctr, Ukyo Ku, Kyoto 6158585, Japan
[4] Univ Calif Los Angeles, UCLA Sch Dent, Sect Oral & Maxillofacial Surg, Los Angeles, CA 90095 USA
基金
日本学术振兴会;
关键词
Immunosensor; Cortisol; Fluid control; Saliva; Stress; TANDEM MASS-SPECTROMETRY; URINARY FREE CORTISOL; STABLE-ISOTOPE DILUTION; SOLID-PHASE EXTRACTION; SERUM TOTAL CORTISOL; CORTICOSTEROIDS; IMMUNOASSAY; DEPRESSION; HORMONES; PLASMA;
D O I
10.1016/j.bios.2012.08.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this research is to demonstrate a new design for a cortisol immunosensor for the noninvasive and quantitative analysis of salivary cortisol. We propose a cortisol immunosensor with a fluid control mechanism which has both a vertical flow and a lateral flow. The detected current resulting from a competitive reaction between the sample cortisol and a glucose oxidase (GOD)-labeled cortisol conjugate was found to be inversely related to the concentration of cortisol in the sample solution. A calibration curve using the relative detected current showed a R-2=0.98 and CV= 14% for a range of standard cortisol solutions corresponding to the concentrations of native salivary cortisol (0.1-10 ng/ml). The measurement could be accomplished within 35 min and the cortisol immunosensor could be reused. These results show promise for realizing an on-site and easy-to-use biosensor for cortisol. Used for evaluation of human salivary cortisol levels, the cortisol immunosensor measurement corresponded closely with commercially available ELISA method (R-2=0.92). Our results indicate the promise of the new cortisol immunosensor for noninvasive, point of care measurement of human salivary cortisol levels. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 35 条
[1]  
Aardal E, 1995, EUR J CLIN CHEM CLIN, V33, P927
[2]   A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF CORTISOL [J].
ATTILI, BS ;
SULEIMAN, AA .
ANALYTICAL LETTERS, 1995, 28 (12) :2149-2159
[3]   Psychobiological and vulnerability : Implications for successful adaptation to extreme stress [J].
Charney, DS .
AMERICAN JOURNAL OF PSYCHIATRY, 2004, 161 (02) :195-216
[4]   Real-time measurements of corticosteroids in conscious animals using an antibody-based electrode [J].
Cook, CJ .
NATURE BIOTECHNOLOGY, 1997, 15 (05) :467-471
[5]   Rapid noninvasive measurement of hormones in transdermal exudate and saliva [J].
Cook, CJ .
PHYSIOLOGY & BEHAVIOR, 2002, 75 (1-2) :169-181
[6]  
Dhabar F.S., 1997, BRAIN BEHAV IMMUN, V1, P286
[7]   Surface plasmon resonance immunosensor for cortisol and cortisone determination [J].
Frasconi, Marco ;
Mazzarino, Monica ;
Botre, Francesco ;
Mazzei, Franco .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (08) :2151-2159
[8]   Determination of the glucocorticoids prednisone, prednisolone, dexamethasone, and cortisol in human serum using liquid chromatography coupled to tandem mass spectrometry [J].
Frerichs, VA ;
Tornatore, KM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02) :329-338
[9]   Simultaneous determination of 6β- and 6α-hydroxycortisols and 6β-hydroxycortisone in human urine by stable isotope dilution mass spectrometry [J].
Furuta, T ;
Matsuzawa, M ;
Shibasaki, H ;
Kasuya, Y .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :367-376
[10]   A comparison of edge- and basal-plane pyrolytic graphite electrodes towards the sensitive determination of hydrocortisone [J].
Goyal, Rajendra N. ;
Chatterjee, Sanghamitra ;
Rana, Anoop Raj Singh .
TALANTA, 2010, 83 (01) :149-155