Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography

被引:73
|
作者
Leong-Poi, H [1 ]
Le, E [1 ]
Rim, SJ [1 ]
Sakuma, T [1 ]
Kaul, S [1 ]
Wei, K [1 ]
机构
[1] Univ Virginia, Hlth Sci Ctr, Sch Med, Div Cardiovasc, Charlottesville, VA 22908 USA
关键词
D O I
10.1067/mje.2001.115982
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although regional myocardial perfusion can be currently quantified with myocardial contrast echocardiography (MCE) by using intermittent harmonic imaging (IHI), the method is tedious and time-consuming in the clinical setting. We hypothesized that regional myocardial perfusion can be quantified and the severity of coronary stenosis determined during hyperemia with MCE using real-time imaging (RTI) where microbubbles are not destroyed. Six open-chest dogs were studied during maximal hyperemia induced by adenosine in the absence or presence of coronary stenoses varying from mild to severe. Myocardial blood flow (MBF) was measured at each stage by using radiolabeled microspheres. MCE was performed using both IHI and RTL Data for the latter were acquired in both end-systole and end-diastole. No differences were found between myocardial flow velocity (MFV) derived from IHI and RTI when end-systolic frames were used for the latter. MFV was consistently higher for RTI (P < .01) when end-diastolic frames were used. A linear relation was noted between MFV and radiolabeled microsphere-derived MBF ratios from the stenosed and the normal beds when end-systolic frames were used for RTI (r = 0.78, P < .001), whereas no relation was found when end-diastolic frames were used (r = 0.08, P =.78). The scatter for assessing MBF (A-P) was minimal for HU and RTI (9%-10%) with end-systolic frames, whereas that for RTI with end-diastolic frames was large (30%). Furthermore the correlation with radiolabeled microsphere-derived MBF was significantly (P < .01) weaker with RTI when end-diastolic frames were used (,r = 0.53) than when end-systolic frames (r = 0.94) or IHI was used (r = 0.99). Data acquisition for IM was 10 minutes, whereas it was 8 seconds for RTL Thus, RTI can be used to quantify regional myocardial perfusion and stenosis severity during MCE. Only end-systolic frames, however, provide accurate data. RTI offers a rapid and easy means of assessing regional myocardial perfusion with MCE.
引用
收藏
页码:1173 / 1182
页数:10
相关论文
共 50 条
  • [21] Comparison of real-time and intermittent triggered myocardial contrast echo for quantification of myocardial perfusion
    Masugata, H
    Peters, B
    Lafitte, S
    Strachan, M
    Yao, B
    Demaria, AN
    CIRCULATION, 2000, 102 (18) : 471 - 472
  • [22] Imaging and quantification of myocardial perfusion using real-time three-dimensional echocardiography
    Toledo, E
    Lang, RM
    Collins, KA
    Lammertin, G
    Williams, U
    Weinert, L
    Bolotin, G
    Coon, PD
    Raman, J
    Jacobs, LD
    Mor-Avi, V
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) : 146 - 154
  • [23] Quantitative Assessment of Perfusion Defect in Coronary Occlusion Models by Real-Time Myocardial Contrast Echocardiography
    Xiao, Zhou
    Zhi, Guang
    Xu, Yong
    Hou, Haijun
    Yan, Guohui
    Ren, Chonglei
    CIRCULATION, 2010, 122 (02) : E297 - E297
  • [24] Quantitative and qualitative analysis of real-time myocardial contrast echocardiography in the detection of coronary artery stenosis
    Rim, SJ
    Kim, HJ
    Ahn, JA
    Cho, DK
    Kang, SM
    Choi, D
    Jang, Y
    Cho, SY
    Chung, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 393A - 393A
  • [25] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    陈立新
    王新房
    Navin C anda
    Andrew P Miller
    谢明星
    庄磊
    杨娅
    王静
    黄润青
    杨颖
    费洪文
    王良玉
    中华医学杂志(英文版), 2004, (03) : 18 - 22
  • [26] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    陈立新
    王新房
    Navin C anda
    Andrew P Miller
    谢明星
    庄磊
    杨娅
    王静
    黄润青
    杨颖
    费洪文
    王良玉
    ChineseMedicalJournal, 2004, (03)
  • [27] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    Chen, LX
    Wang, XF
    Nanda, NC
    Miller, AP
    Xie, MX
    Zhuang, L
    Yang, Y
    Wang, J
    Huang, RQ
    Yang, Y
    Fei, HW
    Wang, LY
    CHINESE MEDICAL JOURNAL, 2004, 117 (03) : 337 - 341
  • [28] Contrast enhanced real-time three-dimensional echocardiography for quantification of myocardial perfusion: a step forward
    Badano, Luigi P.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (04): : 465 - 466
  • [29] Quantitative evaluation of regional myocardial perfusion during dipyridamole stress by real-time myocardial contrast echocardiography in patients with and without coronary artery disease
    Scuteri, L
    De Filippo, P
    Revera, M
    Previtali, M
    Lanzarini, L
    Canosi, U
    Ferlini, M
    Klersy, C
    EUROPEAN HEART JOURNAL, 2003, 24 : 104 - 104
  • [30] INTRAOPERATIVE DETERMINATION OF MYOCARDIAL PERFUSION USING CONTRAST ECHOCARDIOGRAPHY
    SMITH, JS
    FEINSTEIN, SB
    KAPELANSKI, D
    KARP, RB
    GEWERTZ, B
    KEAMY, MF
    SEGIL, L
    BOROW, KM
    ROIZEN, MF
    ANESTHESIOLOGY, 1986, 65 (3A) : A27 - A27