Volumetric Intraoperative Brain Deformation Compensation: Model Development and Phantom Validation

被引:28
作者
DeLorenzo, Christine [1 ]
Papademetris, Xenophon [2 ]
Staib, Lawrence H. [2 ]
Vives, Kenneth P. [3 ]
Spencer, Dennis D. [3 ]
Duncan, James S. [2 ]
机构
[1] Columbia Univ, Dept Psychiat, New York, NY 10032 USA
[2] Yale Univ, Dept Biomed Engn, New Haven, CT 06520 USA
[3] Yale New Haven Med Ctr, Dept Neurosurg, New Haven, CT 06520 USA
基金
美国国家卫生研究院;
关键词
Brain modeling; image processing; image registration; image-guided neurosurgery; IMAGE-GUIDED NEUROSURGERY; LASER RANGE SCANNER; SHIFT COMPENSATION; REGISTRATION; TRACKING; INJURY; SEGMENTATION; ULTRASOUND; SIMULATION; FRAMEWORK;
D O I
10.1109/TMI.2012.2197407
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
During neurosurgery, nonrigid brain deformation may affect the reliability of tissue localization based on preoperative images. To provide accurate surgical guidance in these cases, preoperative images must be updated to reflect the intraoperative brain. This can be accomplished by warping these preoperative images using a biomechanical model. Due to the possible complexity of this deformation, intraoperative information is often required to guide the model solution. In this paper, a linear elastic model of the brain is developed to infer volumetric brain deformation associated with measured intraoperative cortical surface displacement. The developed model relies on known material properties of brain tissue, and does not require further knowledge about intraoperative conditions. To provide an initial estimation of volumetric model accuracy, as well as determine the model's sensitivity to the specified material parameters and surface displacements, a realistic brain phantom was developed. Phantom results indicate that the linear elastic model significantly reduced localization error due to brain shift, from > 16 mm to under 5 mm, on average. In addition, though in vivo quantitative validation is necessary, preliminary application of this approach to images acquired during neocortical epilepsy cases confirms the feasibility of applying the developed model to in vivo data.
引用
收藏
页码:1607 / 1619
页数:13
相关论文
共 57 条
  • [1] Archip N, 2006, Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V6141, P422, DOI DOI 10.1117/12
  • [2] An integrated range-sensing, segmentation and registration framework for the characterization of intra-surgical brain deformations in image-guided surgery
    Audette, MA
    Siddiqi, K
    Ferrie, FP
    Peters, TM
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2003, 89 (2-3) : 226 - 251
  • [3] Audette MA, 1999, LECT NOTES COMPUT SC, V1679, P788
  • [4] BATES LM, 2000, P SOC PHOTO-OPT INS, V1, P58
  • [5] Quantifying brain shift during neurosurgery using spatially-tracked ultrasound
    Blumenthal, T
    Hartov, A
    Lunn, K
    Kennedy, FE
    Roberts, DW
    Paulsen, KD
    [J]. MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 388 - 399
  • [6] Bower A. F., 2009, APPL MECH SOLIDS, P69
  • [7] Bradshaw DRS, 2001, J BIOMECH, V34, P85, DOI 10.1016/S0021-9290(00)00135-4
  • [8] Brands D., 1999, P 43 STAPP CAR CRASH, P313
  • [9] Brands Dave W A, 2002, Stapp Car Crash J, V46, P103
  • [10] Laser range scanning for image-guided neurosurgery: Investigation of image-to-physical space registrations
    Cao, Aize
    Thompson, R. C.
    Dumpuri, P.
    Dawant, B. M.
    Galloway, R. L.
    Ding, S.
    Miga, M. I.
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1593 - 1605