A Simple Strategy to Improve the Accuracy of the Injection Step in Batch Injection Analysis Systems with Amperometric Detection

被引:27
作者
Gimenes, Denise Tofanello [1 ]
Pereira, Polyana Fernandes [1 ]
Cunha, Rafael Rodrigues [1 ]
Bezerra da Silva, Rodrigo Amorim [1 ]
Abarza Munoz, Rodrigo Alejandro [1 ]
Richter, Eduardo Mathias [1 ]
机构
[1] Univ Fed Uberlandia, Inst Quim, Uberlandia, MG, Brazil
关键词
Reproducible manual injection; Internal standard method; Amperometric detection; BIA; BORON-DOPED DIAMOND; FLOW-INJECTION; ELECTROCHEMICAL DETECTION; ELECTRODES; PARACETAMOL; CYSTEINE; ETHANOL; TIME;
D O I
10.1002/elan.201200254
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we describe for the first time the application of an internal standard method to compensate for random errors associated with the injection procedure in batch injection analysis (BIA) systems with multiple pulse amperometric detection. A sequence of potential pulses was selected in such a way that the internal standard (IS) compound was detected individually at one potential pulse and both the IS and analyte, were detected at another potential pulse. The current ratio (IIS+analyte/IIS) was used in the construction of the calibration curve and then to compensate for random errors. The use of disposable syringes or manual pipettes in BIA systems increases the robustness of the method and dispenses with skilled operators.
引用
收藏
页码:1805 / 1810
页数:6
相关论文
共 29 条
[21]   Electrochemical detection of cysteine in a flow system based on reductive desorption of thiols from gold [J].
Possari, Rodrigo ;
Carvalhal, Rafaela Fernanda ;
Mendes, Renata Kelly ;
Kubota, Lauro Tatsuo .
ANALYTICA CHIMICA ACTA, 2006, 575 (02) :172-179
[22]   Batch injection analysis: An almost unexplored powerful tool [J].
Quintino, MSM ;
Angnes, L .
ELECTROANALYSIS, 2004, 16 (07) :513-523
[23]   On the changing electrochemical behaviour of boron-doped diamond surfaces with time after cathodic pre-treatments [J].
Salazar-Banda, Giancarlo R. ;
Andrade, Leonardo S. ;
Nascente, Pedro A. P. ;
Pizani, Paulo S. ;
Rocha-Filho, Romeu C. ;
Avaca, Luis A. .
ELECTROCHIMICA ACTA, 2006, 51 (22) :4612-4619
[24]   Pulsed amperometric detection of ethanol in breath by gold electrodes supported on ion exchange membranes (solid polymer electrolytes) [J].
Schiavon, G ;
Comisso, N ;
Toniolo, R ;
Bontempelli, G .
ELECTROANALYSIS, 1996, 8 (06) :544-548
[25]   A Simple Strategy for Simultaneous Determination of Paracetamol and Caffeine Using Flow Injection Analysis with Multiple Pulse Amperometric Detection [J].
Silva, Wesley C. ;
Pereira, Polyana F. ;
Marra, Mariana C. ;
Gimenes, Denise T. ;
Cunha, Rafael R. ;
da Silva, Rodrigo A. B. ;
Munoz, Rodrigo A. A. ;
Richter, Eduardo M. .
ELECTROANALYSIS, 2011, 23 (12) :2764-2770
[26]   Quadruple-pulsed amperometric detection for simultaneous flow injection determination of glucose and fructose [J].
Surareungchai, W ;
Deepunya, W ;
Tasakorn, P .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :215-220
[27]   Fast and direct determination of butylated hydroxyanisole in biodiesel by batch injection analysis with amperometric detection [J].
Tormin, Thiago Faria ;
Gimenes, Denise Tofanello ;
Richter, Eduardo Mathias ;
Abarza Munoz, Rodrigo Alejandro .
TALANTA, 2011, 85 (03) :1274-1278
[28]   BATCH INJECTION-ANALYSIS [J].
WANG, J ;
TAHA, Z .
ANALYTICAL CHEMISTRY, 1991, 63 (10) :1053-1056
[29]   COMPUTERIZED PIPETTES WITH PROGRAMMABLE DISPENSION FOR BATCH INJECTION-ANALYSIS [J].
WANG, J ;
CHEN, L ;
ANGNES, L ;
TIAN, BM .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :171-177