Synthesis and methodology for optimal design of a parallel remote center of motion mechanism: Application to robotic eye surgery

被引:23
作者
Smits, Jonas [1 ]
Reynaerts, Dominiek [1 ]
Vander Poorten, Emmanuel [1 ]
机构
[1] Univ Leuven, KU Leuven, Dept Mech Engn, Robot Assisted Surg Grp, B-3001 Heverlee, Belgium
基金
比利时弗兰德研究基金会;
关键词
Mechanism design; Kinematic analysis; Remote center of motion; Design optimisation; Optimal design algorithm; Minimally invasive surgery; Surgical robotics; Co-manipulation; KINEMATIC DESIGN; OPTIMIZATION; MANIPULATOR;
D O I
10.1016/j.mechmachtheory.2020.103896
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This work reports on the synthesis of a parallel Remote Center of Motion (RCM) mechanism, and an optimized design for the use-case of robot-assisted vitreoretinal surgery. A 2-DoF planar RCM mechanism is proposed and synthesised as part of a 4-DoF RCM mechanism. The proposed design substantially reduces the occupied volume at the end-effector. This solves a major problem present in related state-of-the-art, which poses limitations on sterile end-effector design and surgical instrument compatibility. Subsequently, an optimal design algorithm is proposed and implemented for the given use-case. The workspace is determined within mechanism constraints, after which performance parameters such as workspace coverage, potential energy, manipulability, reflected stiffness are determined for specific areas of interest within a desired workspace. Subsequently, these parameters are combined in a score function identifying an optimal kinematic design. When compared with the closely-related prior art, the resulting design shows improvements in relevant workspace coverage, reduced gravity compensation effort, and more isotropic manipulability. Overall reflected stiffness is reduced and should be taken into account in future design phases. Future work includes the integration of the kinematic design into a detailed conceptual design and a first prototype development. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:20
相关论文
共 44 条
[1]  
[Anonymous], THESIS
[2]  
[Anonymous], 2014, Advances on Theory and Practice of Robots and Manipulators
[3]   Dionis: A novel remote-center-of-motion parallel manipulator for Minimally Invasive Surgery [J].
Beira, R. ;
Santos-Carreras, L. ;
Rognini, G. ;
Bleuler, H. ;
Clavel, R. .
APPLIED BIONICS AND BIOMECHANICS, 2011, 8 (02) :191-208
[4]  
Caccavale F., 2008, Springer Handbook of Robotics, P701, DOI 10.1007/978-3-540-30301-5_30
[5]   A New Type of Planar Two Degree-of-Freedom Remote Center-of-Motion Mechanism Inspired by the Peaucellier-Lipkin Straight-Line Linkage [J].
Chen, Genliang ;
Wang, Jiepeng ;
Wang, Hao .
JOURNAL OF MECHANICAL DESIGN, 2019, 141 (01)
[6]   Modelling and design issues of a 3-axis parallel machine-tool [J].
Company, O ;
Pierrot, F .
MECHANISM AND MACHINE THEORY, 2002, 37 (11) :1325-1345
[7]   Outcomes of a Multicenter Training Program in Laparoscopic Pancreatoduodenectomy (LAELAPS-2) [J].
de Rooij, Thijs ;
van Hilst, Jony ;
Topal, Baki ;
Bosscha, Koop ;
Brinkman, David J. ;
Gerhards, Michael F. ;
de Hingh, Ignace H. ;
Karsten, Tom M. ;
Lips, Daan J. ;
Luyer, Misha D. ;
Marsman, Hendrik A. ;
van Rijssen, L. Bengt ;
Steen, M. Willemijn ;
Busch, Olivier R. ;
Festen, Sebastiaan ;
Besselink, Marc G. .
ANNALS OF SURGERY, 2019, 269 (02) :344-350
[8]  
Gijbels A, 2013, IEEE INT C INT ROBOT, P3598, DOI 10.1109/IROS.2013.6696869
[9]   In-Human Robot-Assisted Retinal Vein Cannulation, A World First [J].
Gijbels, Andy ;
Smits, Jonas ;
Schoevaerdts, Laurent ;
Willekens, Koen ;
Vander Poorten, Emmanuel B. ;
Stalmans, Peter ;
Reynaerts, Dominiek .
ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (10) :1676-1685
[10]   SMOS - STEREOTAXICAL MICROTELEMANIPULATOR FOR OCULAR SURGERY [J].
GUERROUAD, A ;
VIDAL, P .
IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 :879-880