Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes

被引:104
|
作者
Cohen, Wayne R. [1 ]
Ommani, Sophia [1 ]
Hassan, Sarmina [2 ]
Mirza, Fadi G. [3 ]
Solomon, Molham [1 ]
Brown, Raymond [2 ]
Schifrin, Barry S. [4 ]
Himsworth, John M. [5 ]
Hayes-Gill, Barrie R. [5 ]
机构
[1] Queens Hosp Ctr, Dept Obstet & Gynecol, New York, NY USA
[2] Temple Univ Hosp & Med Sch, Dept Obstet & Gynecol, Philadelphia, PA 19140 USA
[3] Columbia Univ, Med Ctr, Dept Obstet & Gynecol, New York, NY USA
[4] Kaiser Permanente Los Angeles Med Ctr, Los Angeles, CA USA
[5] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
关键词
Fetal heart rate monitoring; electronic fetal monitoring; fetal electrocardiography; cardiotocography; fetal monitoring;
D O I
10.1111/j.1600-0412.2012.01533.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective. Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. Design. Prospective open method equivalence study. Setting. Three urban teaching hospitals in the Northeast United States. Sample. 75 women with normal pregnancies in labor at >37 weeks of gestation. Methods. Three fetal heart rate detection methods were used simultaneously in 75 parturients. The fetal scalp electrode was the standard against which abdominal fetal ECG and ultrasound were judged. Main outcome measures. The positive percent agreement with the fetal scalp electrode indicated reliability. BlandAltman analysis determined accuracy. The confusion rate indicated how frequently the devices tracked the maternal heart rate. Results. Positive percent agreement was 81.7 and 73% for the abdominal fetal ECG and ultrasound, respectively (p = 0.002). The abdominal fetal ECG had a lower root mean square error than ultrasound (5.2 vs. 10.6 bpm, p < 0.001). The confusion rate for ultrasound was 20-fold higher than for abdominal ECG (8.9 vs. 0.4%, respectively, p < 0.001). Conclusion. Compared with the fetal scalp electrode, fetal heart rate detection using abdominal fetal ECG was more reliable and accurate than ultrasound, and abdominal fetal ECG was less likely than ultrasound to display the maternal heart rate in place of the fetal heart rate.
引用
收藏
页码:1306 / 1313
页数:8
相关论文
共 50 条
  • [1] Comment on the article "Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes"
    Fuchs, Tomasz
    Pomorski, Michal
    Grobelak, Krzysztof
    Tomialowicz, Marek
    Zimmer, Mariusz
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2013, 92 (08) : 992 - 992
  • [2] Signal Loss During Fetal Heart Rate Monitoring Using Maternal Abdominal Surface Electrodes Between 28 and 42 Weeks of Pregnancy
    Fuchs, Tomasz
    Pomorski, Michal
    Grobelak, Krzysztof
    Tomialowicz, Marek
    Zimmer, Mariusz
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 23 (05): : 813 - 819
  • [3] Intrapartum monitoring of the fetal heart rate using transabdominal electrocardiography: A reliability and accuracy study
    Wojtanowski, Anne
    Garabedian, Charles
    Charlier, Pierre
    Prot, Pierre
    Ghesquiere, Louise
    De Jonckheere, Julien
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2025, 54 (05)
  • [4] THE FEASIBILITY OF LONG-TERM FETAL HEART-RATE MONITORING IN THE HOME-ENVIRONMENT USING MATERNAL ABDOMINAL ELECTRODES
    CROWE, JA
    HARRISON, A
    HAYESGILL, BR
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (03) : 195 - 202
  • [5] Fetal Heart Rate Monitoring Using Maternal Abdominal Surface Electrodes in Third Trimester: Can We Obtain Additional Information Other than CTG Trace?
    Fuchs, Tomasz
    Grobelak, Krzysztof
    Pomorski, Michal
    Zimmer, Mariusz
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 25 (02): : 309 - 316
  • [6] FETAL HEART-RATE MONITORING USING THE ABDOMINAL FETAL ELECTROCARDIOGRAM
    CARTER, MC
    GUNN, P
    BEARD, RW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1980, 87 (05): : 396 - 401
  • [7] Accuracy and Reliability of Uterine Contraction Identification Using Abdominal Surface Electrodes
    Hayes-Gill, Barrie
    Hassan, Sarmina
    Mirza, Fadi G.
    Ommani, Sophia
    Himsworth, John
    Solomon, Molham
    Brown, Raymond
    Schifrin, Barry S.
    Cohen, Wayne R.
    CLINICAL MEDICINE INSIGHTS-WOMENS HEALTH, 2012, 5 : 65 - 75
  • [8] Towards fetal heart rate monitoring at home using the abdominal fetal electrocardiogram
    Crowe, JA
    Hayes-Gill, BR
    James, DK
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 47 - 48
  • [9] DIRECT MONITORING OF FETAL HEART RATE USING CLIP AND SPIRAL ELECTRODES
    BALASS, S
    TOAFF, ME
    HAREFUAH, 1974, 87 (03) : 115 - 116
  • [10] A New Method to Derive Fetal Heart Rate from Maternal Abdominal Electrocardiogram: Monitoring Fetal Heart Rate during Cesarean Section
    Yeh, Huei-Ming
    Chang, Yi-Chung
    Lin, Chen
    Yeh, Chien-Hung
    Lee, Chien-Nan
    Shyu, Ming-Kwang
    Hung, Ming-Hui
    Hsiao, Po-Ni
    Wang, Yung-Hung
    Tseng, Yu-Hsin
    Tsao, Jenho
    Lai, Ling-Ping
    Lin, Lian-Yu
    Lo, Men-Tzung
    PLOS ONE, 2015, 10 (02):