Risk factors for domestic acquisition of Legionnaires disease

被引:142
作者
Straus, WL
Plouffe, JF
File, TM
Lipman, HB
Hackman, BH
Salstrom, SJ
Benson, RF
Breiman, RF
Baird, I
Emerick, J
Gianakopoulos, G
Herbert, M
Parsons, J
Anderson, CJ
Bollin, GE
Farkas, SA
Francis, SJ
Gardner, WG
Myers, JP
Signs, DJ
Tan, JS
Thomson, RB
Barbaree, J
Fields, B
Morrill, W
Moyenuddin, M
Pruckler, J
StJohn, A
机构
[1] UNIV N CAROLINA, DEPT MED, CHAPEL HILL, NC USA
[2] OHIO STATE UNIV, DEPT MED, COLUMBUS, OH 43210 USA
[3] NE OHIO UNIV, DEPT MED, AKRON, OH 44309 USA
关键词
D O I
10.1001/archinte.156.15.1685
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Legionnaires disease is a common cause of adult pneumonia. Outbreaks of legionnaires disease have been well described, but little is known about sporadically occurring legionnaires disease, which accounts for most infections. Exposure to contaminated residential water sources is 1 plausible means of disease acquisition. Methods: Employing a matched case-control study design in 15 hospitals in 2 Ohio counties, we prospectively enrolled 146 adults diagnosed as having nonepidemic, community-acquired legionnaires disease and compared each with 2 hospital-based control patients, matched for age, sex, and underlying illness category. An interview regarding potential exposures was followed by a home survey that included sampling residential sources for Legionella. Interview and home survey data were analyzed to estimate the risk of acquiring legionnaires disease associated with various exposures. Results: Multivariate analysis showed that a nonmunicipal water supply (odds ratio [OR], 2.26; 95% confidence interval [CI], 1.17-4.37), recent residential plumbing repair (OR, 2.39; 95% CI, 1.10-5.18), and smoking (OR, 3.48; 95% CI, 2.09-5.79) were independent risk factors for legionnaires disease. Univariate analysis suggested that electric (vs gas) water heaters (OR, 1.97; 95% CI, 1.10-3.52), working more than 40 hours weekly (OR, 2.13; 95% CI, 1.12-4.07), and spending nights away from home before illness (OR, 1.68; 95% CI, 1.03-2.74) were additional possible risk factors. Lower chlorine concentrations in potable water and lower water heater temperatures were associated with residential Legionella colonization. Conclusions: A proportion of sporadic cases of legionnaires disease may be residentially acquired and are associated with domestic potable water and disruptions in residential plumbing systems. Potential strategies to reduce legionnaires disease risk include consistent chlorination of potable water, increasing water heater temperatures, and limiting exposure to aerosols after domestic plumbing repairs.
引用
收藏
页码:1685 / 1692
页数:8
相关论文
共 48 条
[1]   COMMUNITY-ACQUIRED LEGIONNAIRES-DISEASE ASSOCIATED WITH A COOLING-TOWER - EVIDENCE FOR LONGER-DISTANCE TRANSPORT OF LEGIONELLA-PNEUMOPHILA [J].
ADDISS, DG ;
DAVIS, JP ;
LAVENTURE, M ;
WAND, PJ ;
HUTCHINSON, MA ;
MCKINNEY, RM .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1989, 130 (03) :557-568
[2]   RISK-FACTORS FOR CONTAMINATION OF DOMESTIC HOT WATER-SYSTEMS BY LEGIONELLAE [J].
ALARY, M ;
JOLY, JR .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (08) :2360-2367
[3]   PREVALENCE AND SIGNIFICANCE OF LEGIONELLA-PNEUMOPHILA CONTAMINATION OF RESIDENTIAL HOT-TAP WATER-SYSTEMS [J].
ARNOW, PM ;
WEIL, D ;
PARA, MF .
JOURNAL OF INFECTIOUS DISEASES, 1985, 152 (01) :145-151
[4]   VARIATION IN TIME AND SPACE OF NON-OUTBREAK LEGIONNAIRES-DISEASE IN SCOTLAND [J].
BHOPAL, RS ;
FALLON, RJ .
EPIDEMIOLOGY AND INFECTION, 1991, 106 (01) :45-61
[5]   PROXIMITY OF THE HOME TO A COOLING-TOWER AND RISK OF NON-OUTBREAK LEGIONNAIRES-DISEASE [J].
BHOPAL, RS ;
FALLON, RJ ;
BUIST, EC ;
BLACK, RJ ;
URQUHART, JD .
BRITISH MEDICAL JOURNAL, 1991, 302 (6773) :378-383
[6]  
BORNSTEIN N, 1986, ISRAEL J MED SCI, V22, P655
[7]   ASSOCIATION OF SHOWER USE WITH LEGIONNAIRES-DISEASE - POSSIBLE ROLE OF AMEBAS [J].
BREIMAN, RF ;
FIELDS, BS ;
SANDEN, GN ;
VOLMER, L ;
MEIER, A ;
SPIKA, JS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (21) :2924-2926
[8]   ROLE OF AIR SAMPLING IN INVESTIGATION OF AN OUTBREAK OF LEGIONNAIRES-DISEASE ASSOCIATED WITH EXPOSURE TO AEROSOLS FROM AN EVAPORATIVE CONDENSER [J].
BREIMAN, RF ;
COZEN, W ;
FIELDS, BS ;
MASTRO, TD ;
CARR, SJ ;
SPIKA, JS ;
MASCOLA, L .
JOURNAL OF INFECTIOUS DISEASES, 1990, 161 (06) :1257-1261
[9]  
BREIMAN RF, 91 M AM SOC MICR
[10]   LEGIONNAIRES-DISEASE OUTBREAK AT AN ATLANTA, GEORGIA, COUNTRY CLUB - EVIDENCE FOR SPREAD FROM AN EVAPORATIVE CONDENSER [J].
CORDES, LG ;
FRASER, DW ;
SKALIY, P ;
PERLINO, CA ;
ELSEA, WR ;
MALLISON, GF ;
HAYES, PS .