Impact of targeting Kt instead of Kt/V

被引:21
作者
Maduell, Francisco [1 ]
Ramos, Rosa [2 ]
Palomares, Ines [2 ]
Martin-Malo, Alejandro [3 ]
Molina, Manolo [4 ]
Bustamante, Jesus [5 ]
Perez-Garcia, Rafael [6 ]
Grassmann, Aileen [7 ]
Ignacio Merello, Jose [2 ]
机构
[1] Univ Barcelona, Hosp Clin, Dept Nephrol & Renal Transplantat, Barcelona, Spain
[2] Fresenius Med Care, NephroCare Med Management, Madrid, Spain
[3] Hosp Univ Reina Sofia, Dept Nephrol, Cordoba, Spain
[4] Hosp Univ Santa Lucia, Dept Nephrol, Murcia, Spain
[5] Hosp Clin Univ Valladolid, Dept Nephrol, Valladolid, Spain
[6] Hosp Univ Infanta Leonor, Dept Nephrol, Madrid, Spain
[7] Fresenius Med Care, Med Board EMEALA, Waltham, MA USA
关键词
adequacy; dialysis dose; ionic dialysance; Kt; online monitoring; BODY-SURFACE AREA; IONIC DIALYSANCE; PATIENT MORTALITY; REAL-TIME; HEMODIALYSIS; SIZE; MEN; RECIRCULATION; CLEARANCE; GENDER;
D O I
10.1093/ndt/gft255
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Patients must receive an adequate dialysis dose in each hemodialysis (HD) session. Ionic dialysance (ID) enables the dialysis dose to be monitored in each session. The aim of this study was to compare the achievement of Kt versus eKt/V values and to analyse the main impediments to reaching the dialysis dose. Of 5316 patients from 54 Fresenius Medical Care centers in Spain undergoing their usual HD regime, 3275 received ID and were included in the study. The minimum prescribed dose of eKt/V was reached in 91.2 of the patients, while the minimum recommended dose of Kt was reached in only 66.8. Patients not receiving the minimum Kt dose were older, had spent 7 months less on dialysis, had a dialysis duration of 6 min less, had 5.7 kg more of body weight and Q(b) was 47 mL/min lower. The target Kt was not reached by 62 of patients with catheters and by 37 of women. With each quintile increase of body weight, eKt/V decreased and Kt increased. Of patients with a body weight 80 kg, 1.4, mostly men, reached the target Kt but not prescribed eKt/V. The impact of monitoring the dose with Kt instead of Kt/V is that identifies 25.8 of patients who did not reach the minimum Kt while achieving Kt/V. The main impediments to achieving an adequate dialysis dose were catheter use, female sex, advanced age, greater body weight, shorter dialysis time and lower Qb.
引用
收藏
页码:2595 / 2603
页数:9
相关论文
共 50 条
[31]   Fractional solute removal and KT/V in different modalities of renal replacement therapy [J].
Waniewski, J ;
Lindholm, B .
BLOOD PURIFICATION, 2004, 22 (04) :367-376
[32]   Comparison between different methods of calculating Kt/V as the marker of adequacy of dialysis [J].
Fazl-e-Mateen ;
Ahmad, Sajad ;
Elahi, Irfan ;
Anees, Muhammad .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (01) :167-171
[33]   Mathematical Representation of Standard Kt/V Including Ultrafiltration and Residual Renal Function [J].
Sternby, Jan .
ASAIO JOURNAL, 2018, 64 (05) :E88-E93
[34]   Blood flow rate: An important determinant of urea clearance and delivered Kt/V [J].
Ward, RA .
ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (01) :75-79
[35]   Standard Kt/V thresholds to accurately predict single-pool Kt/V targets for children receiving thrice-weekly maintenance haemodialysis [J].
Mammen, Cherry ;
Goldstein, Stuart L. ;
Milner, Ruth ;
White, Colin Thomas .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2010, 25 (09) :3044-3050
[36]   Frequency and causes of discrepancy between Kt/V and creatinine clearance [J].
Satko, SG ;
Burkart, JM ;
Bleyer, AJ ;
Jordan, JR ;
Manning, T .
PERITONEAL DIALYSIS INTERNATIONAL, 1999, 19 (01) :31-37
[37]   Influence of the ionic dialysance monitor on Kt measurement in hemodialysis [J].
Maduell, Francisco ;
Vera, Manel ;
Arias, Marta ;
Serra, Nuria ;
Blasco, Miguel ;
Bergada, Eduardo ;
Fontsere, Nestor ;
Cases, Aleix ;
Campistol, Josep M. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 52 (01) :85-92
[38]   Natural logarithmic estimates of Kt/V in the pediatric hemodialysis population [J].
Goldstein, SL ;
Sorof, JM ;
Brewer, ED .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (03) :518-522
[39]   Once upon a time in dialysis: the last days of Kt/V? [J].
Vanholder, Raymond ;
Glorieux, Griet ;
Eloot, Sunny .
KIDNEY INTERNATIONAL, 2015, 88 (03) :460-465
[40]   Peritoneal dialysis can maintain nitrogen balance with low Kt/V in anuric patients [J].
Su, Chun-yan ;
Lu, Xin-hong ;
Tang, Wen ;
Wang, Pei-yu ;
Wang, Tao .
CLINICAL NEPHROLOGY, 2022, 97 (04) :206-214