Impact of targeting Kt instead of Kt/V

被引:21
作者
Maduell, Francisco [1 ]
Ramos, Rosa [2 ]
Palomares, Ines [2 ]
Martin-Malo, Alejandro [3 ]
Molina, Manolo [4 ]
Bustamante, Jesus [5 ]
Perez-Garcia, Rafael [6 ]
Grassmann, Aileen [7 ]
Ignacio Merello, Jose [2 ]
机构
[1] Univ Barcelona, Hosp Clin, Dept Nephrol & Renal Transplantat, Barcelona, Spain
[2] Fresenius Med Care, NephroCare Med Management, Madrid, Spain
[3] Hosp Univ Reina Sofia, Dept Nephrol, Cordoba, Spain
[4] Hosp Univ Santa Lucia, Dept Nephrol, Murcia, Spain
[5] Hosp Clin Univ Valladolid, Dept Nephrol, Valladolid, Spain
[6] Hosp Univ Infanta Leonor, Dept Nephrol, Madrid, Spain
[7] Fresenius Med Care, Med Board EMEALA, Waltham, MA USA
关键词
adequacy; dialysis dose; ionic dialysance; Kt; online monitoring; BODY-SURFACE AREA; IONIC DIALYSANCE; PATIENT MORTALITY; REAL-TIME; HEMODIALYSIS; SIZE; MEN; RECIRCULATION; CLEARANCE; GENDER;
D O I
10.1093/ndt/gft255
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Patients must receive an adequate dialysis dose in each hemodialysis (HD) session. Ionic dialysance (ID) enables the dialysis dose to be monitored in each session. The aim of this study was to compare the achievement of Kt versus eKt/V values and to analyse the main impediments to reaching the dialysis dose. Of 5316 patients from 54 Fresenius Medical Care centers in Spain undergoing their usual HD regime, 3275 received ID and were included in the study. The minimum prescribed dose of eKt/V was reached in 91.2 of the patients, while the minimum recommended dose of Kt was reached in only 66.8. Patients not receiving the minimum Kt dose were older, had spent 7 months less on dialysis, had a dialysis duration of 6 min less, had 5.7 kg more of body weight and Q(b) was 47 mL/min lower. The target Kt was not reached by 62 of patients with catheters and by 37 of women. With each quintile increase of body weight, eKt/V decreased and Kt increased. Of patients with a body weight 80 kg, 1.4, mostly men, reached the target Kt but not prescribed eKt/V. The impact of monitoring the dose with Kt instead of Kt/V is that identifies 25.8 of patients who did not reach the minimum Kt while achieving Kt/V. The main impediments to achieving an adequate dialysis dose were catheter use, female sex, advanced age, greater body weight, shorter dialysis time and lower Qb.
引用
收藏
页码:2595 / 2603
页数:9
相关论文
共 50 条
  • [21] Calculation of Kt/V and creatine clearance in APD
    Viglino, G
    Neri, L
    Gandolfo, C
    Cavalli, PL
    ADVANCES IN PERITONEAL DIALYSIS/1998, VOL 14, 1998, 14 : 68 - 71
  • [22] Comparative study of the Kt/V calculated by algorithms
    Prado, M
    Roa, LM
    Palma, A
    Milan, JA
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1820 - 1821
  • [23] Measuring Kt by ionic dialysance is a useful tool for assessing dialysis dose in critical patients
    Rosa Diez, G. J.
    Bevione, P.
    Crucelegui, M. S.
    Bratti, G.
    Bonfanti, W.
    Varela, F.
    Algranati, S.
    Giannasi, S.
    San Roman, E.
    Heguilen, R.
    Greloni, G.
    NEFROLOGIA, 2010, 30 (02): : 227 - 231
  • [24] Comparison of methods to predict equilibrated Kt/V in the HEMO pilot study
    Eknoyan, G
    Kopple, J
    Levey, A
    Levin, N
    Schulman, G
    Beck, G
    Kusek, J
    Daugirdas, JT
    Depner, TA
    Gotch, FA
    Greene, T
    Keshaviah, P
    Levin, NW
    KIDNEY INTERNATIONAL, 1997, 52 (05) : 1395 - 1405
  • [25] Reassessing the utility of access recirculation and Kt/V for the prediction of arteriovenous fistula failure using online clearance monitoring: the SHUNT STUDY
    Bodington, Richard
    Hazara, Adil M.
    Lamplugh, Archie
    Syed, Ahsan
    Bhandari, Sunil
    JOURNAL OF NEPHROLOGY, 2023, 36 (03) : 677 - 686
  • [26] Hemodialysis Time and Kt/V: Less May Be Better
    Tattersall, James
    SEMINARS IN DIALYSIS, 2017, 30 (01) : 10 - 14
  • [27] Effect of intradialytic parenteral nutrition on delivered Kt V
    McCann, L
    Feldman, C
    Hornberger, J
    Belanger, S
    Maru, L
    Torres, M
    Tootell, F
    Gotch, F
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (06) : 1131 - 1135
  • [28] Adequacy of CPD: Comparing Kt/V and creatinine clearance
    Juergensen, PH
    Allen, JR
    Kliger, AS
    Finkelstein, FO
    ADVANCES IN PERITONEAL DIALYSIS/1998, VOL 14, 1998, 14 : 72 - 74
  • [29] Relationship between the different methods to calculate Kt/V
    Teruel, JL
    Lucas, MF
    Sánchez, JL
    Rodríguez, JR
    Rivera, M
    Marcén, R
    Ortuño, J
    NEFROLOGIA, 2000, 20 (01): : 72 - 78
  • [30] Online Clearance Monitoring With Electrical Conductance (Dt/V) Versus Blood-driven (Kt/V) of Urea: A Compressional Study
    Tayebi-Khosroshahi, Hamid
    Ghahremanzadeh, Arman
    Ghojazedeh, Morteza
    Dehgan, Jeyran
    IRANIAN JOURNAL OF KIDNEY DISEASES, 2022, 16 (05) : 304 - 310