Supine/left decubitus scanning: a valuable alternative to supine/prone scanning in CT colonography

被引:32
作者
Gryspeerdt, SS [1 ]
Herman, MJ [1 ]
Baekelandt, MA [1 ]
van Holsbeeck, BG [1 ]
Lefere, PA [1 ]
机构
[1] Stedelijk Ziekenhuis, Dept Radiol, B-8800 Roeselare, Belgium
关键词
CT colonography; dual positioning; distension; breathing artefacts; residus; polyp detection;
D O I
10.1007/s00330-004-2264-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to evaluate supine/left decubitus as an alternative to supine/prone scanning in computed tomographic colonography (CT colonography). Fifty patients were randomised to supine/prone, another 50 to supine/left decubitus scanning. Patients were scanned using a single-slice CT scanner. The colon was divided into eight segments. Comparisons of distension, breathing artefacts, residus and polyp detection were made between the two groups as well as between the different positions. Adequate distension was found in approximately 85, 97 and 95% of segments in the supine, prone and left decubitus positions, respectively. Combined scanning increased the percentage of adequate distension to 98.5% for prone-supine and 97.7% for left decubitus-supine scanning (P<0.0005 compared to supine, P=0.001 compared to left decubitus and P=0.046 compared to prone scanning). Absence of residual material was found in approximately 62.7, 69.7 and 64% of segments in the supine, prone and left decubitus positions, respectively. Combined scanning increased this percentage to approximately 99% for both groups. No significant differences towards distension or residual material were found between combined supine-prone or supine-left decubitus scanning. In the supine-prone group, combined scanning additionally revealed four lesions and improved conspicuity in two cases of stalked polyps. In the supine-left decubitus group, combined scanning additionally revealed two lesions and improved conspicuity in one stalked polyp. There were significantly fewer breathing artefacts with left decubitus scanning than prone scanning (P=0.005). A strong positive correlation was found between breathing artefacts and the age of patients in both patient groups. Colonic distension and preparation is improved by using supine and prone or supine and left decubitus scanning in combination, with a subsequent improved polyp detection. There were no significant differences between the two scanning protocols. Prone scanning, however, is hampered by breathing artefacts, especially in the elderly. Therefore, supine-left decubitus scanning is considered a valuable alternative to supine-prone scanning for the elderly.
引用
收藏
页码:768 / 777
页数:10
相关论文
共 28 条
[1]   Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results [J].
Bielen, D ;
Thomeer, M ;
Vanbeckevoort, D ;
Kiss, G ;
Maes, F ;
Marchal, G ;
Rutgeerts, P .
EUROPEAN RADIOLOGY, 2003, 13 (03) :453-458
[2]   Clinical results by CT colonoscopy [J].
Bruzzi, JF ;
Moss, AC ;
Fenlon, HM .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2188-2194
[3]   CT colonography: Value of scanning in both the supine and prone positions [J].
Chen, SC ;
Lu, DSK ;
Hecht, JR ;
Kadell, BM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :595-599
[4]   CT OF THE COLON IN FRAIL ELDERLY PATIENTS [J].
DIXON, AK ;
FREEMAN, AH ;
CONI, NK .
SEMINARS IN ULTRASOUND CT AND MRI, 1995, 16 (02) :165-172
[5]   CT colonography and MR colonography: current status, research directions and comparison [J].
Fletcher, JG ;
Luboldt, W .
EUROPEAN RADIOLOGY, 2000, 10 (05) :786-801
[6]   CT colonography: Potential pitfalls and problem-solving techniques [J].
Fletcher, JG ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
Reed, JE ;
Hara, AK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1271-1278
[7]   Optimization of CT colonography technique: Prospective trial in 180 patients [J].
Fletcher, JG ;
Johnson, CD ;
Welch, TJ ;
MacCarty, RL ;
Ahlquist, DA ;
Reed, JE ;
Harmsen, WS ;
Wilson, LA .
RADIOLOGY, 2000, 216 (03) :704-711
[8]  
Gryspeerdt SS, 2000, RADIOLOGY, V217, P170
[9]   CT colonography: Single-versus multi-detector row imaging [J].
Hara, AK ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
McCollough, CH ;
Harmen, WS .
RADIOLOGY, 2001, 219 (02) :461-465
[10]  
Jolles H, 1994, J Thorac Imaging, V9, P273, DOI 10.1097/00005382-199423000-00010