Experimental investigation of the re-centring capability of curved surface sliders

被引:32
作者
Quaglini, Virginio [1 ]
Gandelli, Emanuele [1 ]
Dubini, Paolo [1 ]
机构
[1] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
关键词
base isolation; curved surface sliders; re-centring capability; shake-table test; displacement accrual; residual displacement; SEISMIC ISOLATION; SLIDING BEARINGS; BASE-ISOLATION; SHAKING TABLE; TECHNOLOGY; EARTHQUAKE; BEHAVIOR; SYSTEM;
D O I
10.1002/stc.1870
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The re-centring capability is recognized as a fundamental function of the isolation system, because it is intended to prevent substantial permanent deformation at the end of the earthquake that may affect the serviceability of the structure and eventually limit the capability of the isolators to withstand aftershocks and future earthquakes. In this study, the re-centring behaviour of isolation systems composed of sliding bearings with curved surfaces is investigated in shake-table tests carried out on a one-storey steel frame with rectangular plan, scaled at one third-length scale and isolated with four bearings. The coefficient of friction of the bearings is varied by changing the material or lubrication condition of the pads, providing different equivalent damping ratios to the isolation system. The response of the base isolated structure to selected natural ground motion waveforms is assessed in terms of the residual displacement after a single event and the accrual of displacements during a sequence of quakes, and considerations on the influence of the coefficient of friction on the re-centring behaviour, as well as on the effect of an initial displacement offset are drawn. The re-centring provision of the current European design code is eventually checked against the experimental data. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页数:17
相关论文
共 45 条
  • [1] Al-Hussaini T.M., 1994, SEISMIC ISOLATION MU
  • [2] [Anonymous], 2010, MIN DELOADBUILD
  • [3] [Anonymous], 2002, Internet-Site for European strong-motion data
  • [4] [Anonymous], 2005, 199822005A12011 EN, Patent No. EN1998-2:2005 + A1:2011
  • [5] Self-centring capacity of seismic isolation systems
    Berton, Stefano
    Infanti, S.
    Castellano, M. G.
    Hikosaka, H.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (06) : 895 - 914
  • [6] Bozzo S, 1995, STRUCT CONTROL HLTH, V2, P59, DOI [10.1002/stc.4300020203, DOI 10.1002/STC.4300020203]
  • [7] Shaking table investigation of a novel, low-cost, base isolation technology using recycled rubber
    Calabrese, Andrea
    Spizzuoco, Mariacristina
    Serino, Giorgio
    Della Corte, Gaetano
    Maddaloni, Giuseppe
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (01) : 107 - 122
  • [8] Restoring capability of friction pendulum seismic isolation systems
    Cardone, D.
    Gesualdi, G.
    Brancato, P.
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (08) : 2449 - 2480
  • [9] Carydis P, 2012, Ing Sismica, P31
  • [10] CEN (Comite Europeen de Normalisation), 2009, Anti-seismic devices