Force-detecting gripper and force feedback system for neurosurgery applications

被引:24
作者
Yoneyama, Takeshi [1 ]
Watanabe, Tetsuyou [1 ]
Kagawa, Hiroyuki [1 ]
Hamada, Junichiro [2 ]
Hayashi, Yutaka [2 ]
Nakada, Mitsutoshi [2 ]
机构
[1] Kanazawa Univ, Sch Mech Engn, Kanazawa, Ishikawa 9201192, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Neurosurg, Kanazawa, Ishikawa 9208641, Japan
关键词
Neurosurgery; Robotic surgery; Brain tumor; Manipulator; Force feedback; MICROMANIPULATOR SYSTEM; CLINICAL-APPLICATION; ROBOTIC SURGERY; TELEMANIPULATION; NEUROBOT; FUTURE;
D O I
10.1007/s11548-012-0807-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose For the application of less invasive robotic neurosurgery to the resection of deep-seated tumors, a prototype system of a force-detecting gripper with a flexible micromanipulator and force feedback to the operating unit will be developed. Methods Gripping force applied on the gripper is detected by strain gauges attached to the gripper clip. The signal is transmitted to the amplifier by wires running through the inner tube of the manipulator. Proportional force is applied on the finger lever of the operating unit by the surgeon using a bilateral control program. A pulling force experienced by the gripper is also detected at the gripper clip. The signal for the pulling force is transmitted in a manner identical to that mentioned previously, and the proportional torque is applied on the touching roller of the finger lever of the operating unit. The surgeon can feel the gripping force as the resistance of the operating force of the finger and can feel the pulling force as the friction at the finger surface. Results A basic operation test showed that both the gripping force and pulling force were clearly detected in the gripping of soft material and that the operator could feel the gripping force and pulling force at the finger lever of the operating unit. Conclusions A prototype of the force feedback in the microgripping manipulator system has been developed. The system will be useful for removing deep-seated brain tumors in future master-slave-type robotic neurosurgery.
引用
收藏
页码:819 / 829
页数:11
相关论文
共 26 条
[21]  
Takahashi H, 2006, 1 IEEE RASEMBS INT C, P284
[22]   Design issues in a haptics-based master-slave system for minimally invasive surgery [J].
Tavakoli, M ;
Patel, R ;
Moallem, M .
2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, :371-376
[23]   Robotics in urology: Past, present, and future [J].
Thiel, David D. ;
Winfield, Howard N. .
JOURNAL OF ENDOUROLOGY, 2008, 22 (04) :825-830
[24]   MICA - A new generation of versatile instruments in robotic surgery [J].
Thielmann, Sophie ;
Seibold, Ulrich ;
Haslinger, Robert ;
Passig, Georg ;
Bahls, Thomas ;
Joerg, Stefan ;
Nickl, Mathias ;
Nothhelfer, Alexander ;
Hagn, Ulrich ;
Hirzinger, Gerd .
IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, :871-878
[25]   A modular, automated laparoscopic grasper with three-dimensional force measurement capability [J].
Tholey, Gregory ;
Desai, Jaydev P. .
PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, :250-255
[26]  
Yoneyama T, 2011, 33 ANN INT C IEEE EM, P6695