High-precision measurements of δ2H, δ18O and δ17O in water with the aid of cavity ring-down laser spectroscopy

被引:28
作者
Pierchala, Anna [1 ]
Rozanski, Kazimierz [1 ]
Dulinski, Marek [1 ]
Gorczyca, Zbigniew [1 ]
Marzec, Michal [1 ]
Czub, Robert [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Krakow, Poland
关键词
Cavity ring-down spectroscopy; hydrogen-2; isotope measurements; methods and equipment; oxygen-17; excess; oxygen-18; QA; QC; uncertainty; ISOTOPE-RATIO; SPECTROMETER; CALIBRATION; O-17-EXCESS; SURFACES; OXYGEN;
D O I
10.1080/10256016.2019.1609959
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A thorough evaluation of measurement uncertainty together with control of short-term and long-term precision of measurements should be a basis of any successful quality assurance/quality control (QA/QC) strategy aimed at maintaining a high quality of the analytical process. Here we present the results of a comprehensive assessment of the analytical performance of a Picarro L2140-i CRDS laser spectrometer analysing delta H-2, delta O-18 and delta O-17 in water. The assessment is based on results obtained during 15 months of continuous operation of this instrument (February 2017 to May 2018). The short-term precision of measured and derived quantities was 0.11, 0.036, 0.028, 0.23 parts per thousand and 11 per meg, for delta H-2, delta O-18, delta O-17, d-excess and Delta O-17, respectively, and is comparable to the precision reported by the manufacturer. The long-term precision of the L2140-i, defined as standard uncertainty of the time series of 153 analyses of a laboratory standard conducted throughout 15 months, was roughly two times lower (0.24, 0.053, 0.038, 0.37 parts per thousand and 21 per meg, for delta H-2, delta O-18, delta O-17, d-excess and Delta O-17). In-depth assessment of the measurement uncertainty of a single analysis revealed that assigned uncertainty of the calibration standards is an important component of the uncertainty budget, especially in case of delta H-2 analysis.
引用
收藏
页码:290 / 307
页数:18
相关论文
共 31 条
[11]  
Groning M., 2018, 01 TEL INT AT EN AG
[12]  
International Organization for Standardization (ISO), 2015, 135282015 ISO, P28
[13]  
Kazemi G.A., 2006, GROUNDWATER AGE
[14]   The triple isotopic composition of oxygen in leaf water [J].
Landais, A. ;
Barkan, E. ;
Yakir, D. ;
Luz, B. .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (16) :4105-4115
[15]   Variations of 17O/16O and 18O/16O in meteoric waters [J].
Luz, Boaz ;
Barkan, Eugeni .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2010, 74 (22) :6276-6286
[16]   THE DEVELOPMENT OF A HIGH-RESOLUTION MASS-SPECTROMETER - A REMINISCENCE [J].
NIER, AO .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (06) :447-452
[17]   Reconstruction of past climates from stable isotope records of palaeo-precipitation preserved in continental archives [J].
Rozanski, K ;
Johnsen, SJ ;
Schotterer, U ;
Thompson, LG .
HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1997, 42 (05) :725-745
[18]   Routine high-precision analysis of triple water-isotope ratios using cavity ring-down spectroscopy [J].
Schauer, Andrew J. ;
Schoenemann, Spruce W. ;
Steig, Eric J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (18) :2059-2069
[19]   Stable Isotope Analysis of Saline Water Samples on a Cavity Ring-down Spectroscopy Instrument [J].
Skrzypek, Grzegorz ;
Ford, Douglas .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (05) :2827-2834
[20]   Calibrated high-precision 17O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance [J].
Steig, E. J. ;
Gkinis, V. ;
Schauer, A. J. ;
Schoenemann, S. W. ;
Samek, K. ;
Hoffnagle, J. ;
Dennis, K. J. ;
Tan, S. M. .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (08) :2421-2435