Compact optical diagnostic device for isothermal nucleic acids amplification

被引:49
作者
Lee, Szu-Yuan [2 ,3 ,4 ]
Huang, Jhen-Gang [2 ]
Chuang, Tsung-Liang [2 ]
Sheu, Jin-Chuan [5 ]
Chuang, Yi-Kuang [6 ]
Holl, Mark [7 ,8 ,9 ]
Meldrum, Deirdre R. [7 ,8 ,9 ]
Lee, Chun-Nan [3 ]
Lin, Chii-Wann [1 ,2 ,10 ,11 ]
机构
[1] Natl Taiwan Univ, Coll Med, Inst Biomed Engn, Med Microsensor & Syst Lab, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Coll Engn, Taipei 106, Taiwan
[3] Natl Taiwan Univ, Dept Clin Lab Sci & Med Biotechnol, Taipei 106, Taiwan
[4] Mil Taichung Gen Hosp, Dept Lab Examinat, Taichung, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Lab Med, Taipei, Taiwan
[7] Arizona State Univ, Ira A Fulton Sch Engn, Phoenix, AZ USA
[8] Arizona State Univ, Dept Elect Engn, Phoenix, AZ USA
[9] Arizona State Univ, Biodesign Inst, Ctr Ecogenom, Phoenix, AZ USA
[10] Natl Taiwan Univ, Inst Elect Engn, Taipei 106, Taiwan
[11] Natl Taiwan Univ, Ctr Nano Sci & Technol, Taipei 106, Taiwan
关键词
LAMP; isothermal; diagnostic device; hepatitis B virus;
D O I
10.1016/j.snb.2008.03.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We recently reported the successful use of the loop-mediated isothermal amplification (LAMP) reaction for hepatitis B virus (HBV) DNA amplification and its optimal primer design method. In this study, we report the development of an integrated isothermal device for both amplification and detection of targeted HBV DNA. It has two major components, a disposable polymethyl methacrylate (PMMA) micro-reactor and a temperature-regulated optical detection unit (base apparatus) for real-time monitoring of the turbidity changes due to the precipitation of DNA amplification by-product, magnesium pyrophosphate. We have established a correlation curve (R-2 = 0.99) between the concentration of pyrophosphate ions and the level of turbidity by using a simulated chemical reaction to evaluate the characteristics of our device. For the applications of rapid pathogens detection, we also have established a standard curve (R-2 = 0.96) by using LAMP reaction with a standard template in our device. Moreover, we also have successfully used the device on seven clinical serum specimens where HBV DNA levels have been confirmed by real-time PCR. The result indicates that different amounts of HBV DNA can be successfully detected by using this device within 1 h. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 50 条
  • [31] Gold nanoparticle-mediated nucleic acid isothermal amplification with enhanced specificity
    Ye, Xin
    Fang, Xueen
    Li, Xinxin
    Kong, Jilie
    ANALYTICA CHIMICA ACTA, 2018, 1043 : 150 - 157
  • [32] Low-Cost, Open-Source Device for High-Performance Fluorescence Detection of Isothermal Nucleic Acid Amplification Reactions
    Buultjens, Andrew H.
    Vandelannoote, Koen
    Sharkey, Liam K.
    Howden, Benjamin P.
    Monk, Ian R.
    Lee, Jean Y. H.
    Stinear, Timothy P.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (10) : 4982 - 4990
  • [33] Rapid Detection of Human Adenovirus by Loop-Mediated Isothermal Amplification of Nucleic Acids Extracted Using Magnetic Nanoparticle Enrichment Technology
    Hu, Guohong
    Ma, Xinye
    Zhang, Xinyu
    Wu, Zhihui
    Wu, Yanqi
    Chu, Zhou
    Chen, Hui
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2023, 19 (03) : 376 - 382
  • [34] Isothermal Nucleic Acid Amplification for Point-of-Care Primary Cervical Cancer Screening
    Lamsisi, Maryame
    Benlghazi, Abdelhamid
    Kouach, Jaouad
    Laraqui, Abdelilah
    Ennaji, Moulay Mustapha
    Chauleur, Celine
    Bourlet, Thomas
    Li, Guorong
    VIRUSES-BASEL, 2024, 16 (12):
  • [35] Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes
    Tanner, Nathan A.
    Zhang, Yinhua
    Evans, Thomas C., Jr.
    BIOTECHNIQUES, 2015, 58 (02) : 59 - 68
  • [36] Locked nucleic acid molecular beacon for multiplex detection of loop mediated isothermal amplification
    Bakthavathsalam, Padmavathy
    Longatte, Guillaume
    Jensen, Slade O.
    Manefield, Mike
    Gooding, J. Justin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 268 : 255 - 263
  • [37] Long-tail probe-mediated cycled strand displacement amplification: Label-free, isothermal and sensitive detection of nucleic acids
    Su, Hongyan
    Long, Jiabao
    Guo, Qiuping
    Meng, Xiaochun
    Tan, Yongjun
    Cai, Qingyun
    Chen, Zhuo
    Meng, Xiangxian
    TALANTA, 2013, 116 : 330 - 334
  • [38] EzyAmp signal amplification cascade enables isothermal detection of nucleic acid and protein targets
    Linardy, Evelyn M.
    Erskine, Simon M.
    Lima, Nicole E.
    Lonergan, Tina
    Mokany, Elisa
    Todd, Alison V.
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 59 - 66
  • [39] Interfacial Effect-Based Quantification of Droplet Isothermal Nucleic Acid Amplification for Bacterial Infection
    Ulep, Tiffany-Heather
    Day, Alexander S.
    Sosnowski, Katelyn
    Shumaker, Alexa
    Yoon, Jeong-Yeol
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [40] Rapid and Sensitive Isothermal Detection of Nucleic-acid Sequence by Multiple Cross Displacement Amplification
    Wang, Yi
    Wang, Yan
    Ma, Ai-Jing
    Li, Dong-Xun
    Luo, Li-Juan
    Liu, Dong-Xin
    Jin, Dong
    Liu, Kai
    Ye, Chang-Yun
    SCIENTIFIC REPORTS, 2015, 5