Compact optical diagnostic device for isothermal nucleic acids amplification

被引:49
|
作者
Lee, Szu-Yuan [2 ,3 ,4 ]
Huang, Jhen-Gang [2 ]
Chuang, Tsung-Liang [2 ]
Sheu, Jin-Chuan [5 ]
Chuang, Yi-Kuang [6 ]
Holl, Mark [7 ,8 ,9 ]
Meldrum, Deirdre R. [7 ,8 ,9 ]
Lee, Chun-Nan [3 ]
Lin, Chii-Wann [1 ,2 ,10 ,11 ]
机构
[1] Natl Taiwan Univ, Coll Med, Inst Biomed Engn, Med Microsensor & Syst Lab, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Coll Engn, Taipei 106, Taiwan
[3] Natl Taiwan Univ, Dept Clin Lab Sci & Med Biotechnol, Taipei 106, Taiwan
[4] Mil Taichung Gen Hosp, Dept Lab Examinat, Taichung, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Lab Med, Taipei, Taiwan
[7] Arizona State Univ, Ira A Fulton Sch Engn, Phoenix, AZ USA
[8] Arizona State Univ, Dept Elect Engn, Phoenix, AZ USA
[9] Arizona State Univ, Biodesign Inst, Ctr Ecogenom, Phoenix, AZ USA
[10] Natl Taiwan Univ, Inst Elect Engn, Taipei 106, Taiwan
[11] Natl Taiwan Univ, Ctr Nano Sci & Technol, Taipei 106, Taiwan
关键词
LAMP; isothermal; diagnostic device; hepatitis B virus;
D O I
10.1016/j.snb.2008.03.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We recently reported the successful use of the loop-mediated isothermal amplification (LAMP) reaction for hepatitis B virus (HBV) DNA amplification and its optimal primer design method. In this study, we report the development of an integrated isothermal device for both amplification and detection of targeted HBV DNA. It has two major components, a disposable polymethyl methacrylate (PMMA) micro-reactor and a temperature-regulated optical detection unit (base apparatus) for real-time monitoring of the turbidity changes due to the precipitation of DNA amplification by-product, magnesium pyrophosphate. We have established a correlation curve (R-2 = 0.99) between the concentration of pyrophosphate ions and the level of turbidity by using a simulated chemical reaction to evaluate the characteristics of our device. For the applications of rapid pathogens detection, we also have established a standard curve (R-2 = 0.96) by using LAMP reaction with a standard template in our device. Moreover, we also have successfully used the device on seven clinical serum specimens where HBV DNA levels have been confirmed by real-time PCR. The result indicates that different amounts of HBV DNA can be successfully detected by using this device within 1 h. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 50 条
  • [21] Miniature isothermal amplification reactor with an integrated optical detection unit
    Lee, Szu-Yuan
    Yang, Lung-Jieh
    Meldrum, Deirdre R.
    Lee, Chun-Nan
    Lin, Chii-Wann
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 648 - +
  • [22] Isothermal Nucleic Acid Amplification-Based Lateral Flow Testing for the Detection of Plant Viruses
    Song, Xuemei
    Cao, Yuhao
    Yan, Fei
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (08)
  • [23] A review of reaction enhancement strategies for isothermal nucleic acid amplification reactions
    Ozay, Burcu
    McCalla, Stephanie E.
    SENSORS AND ACTUATORS REPORTS, 2021, 3
  • [24] A novel method to control carryover contamination in isothermal nucleic acid amplification
    Ma, Cuiping
    Wang, Fuxin
    Wang, Xiudan
    Han, Lingzhi
    Jing, Hao
    Zhang, Heng
    Shi, Chao
    CHEMICAL COMMUNICATIONS, 2017, 53 (77) : 10696 - 10699
  • [25] Point-of-Care Multiplexed Assays of Nucleic Acids Using Microcapillary-based Loop-Mediated Isothermal Amplification
    Zhang, Yi
    Zhang, Lu
    Sun, Jiashu
    Liu, Yulei
    Ma, Xingjie
    Cui, Shangjin
    Ma, Liying
    Xi, Jianzhong Jeff
    Jiang, Xingyu
    ANALYTICAL CHEMISTRY, 2014, 86 (14) : 7057 - 7062
  • [26] Rapid diagnosis of Leishmania infection with a portable loop-mediated isothermal amplification device
    Madhu Puri
    Harsimran Kaur Brar
    Nimisha Mittal
    Evanka Madan
    Rajesh Srinivasan
    Kapil Rawat
    Srija Moulik
    Mitali Chatterjee
    Sai Siva Gorthi
    Rohini Muthuswami
    Rentala Madhubala
    Journal of Biosciences, 2021, 46
  • [27] Rapid diagnosis of Leishmania infection with a portable loop-mediated isothermal amplification device
    Puri, Madhu
    Brar, Harsimran Kaur
    Mittal, Nimisha
    Madan, Evanka
    Srinivasan, Rajesh
    Rawat, Kapil
    Moulik, Srija
    Chatterjee, Mitali
    Gorthi, Sai Siva
    Muthuswami, Rohini
    Madhubala, Rentala
    JOURNAL OF BIOSCIENCES, 2021, 46 (04)
  • [28] Isothermal nucleic acid amplification techniques for detection and identification of pathogenic fungi: A review
    Zatti, Matheus Silva
    Arantes, Thales Domingos
    Theodoro, Raquel Cordeiro
    MYCOSES, 2020, 63 (10) : 1006 - 1020
  • [29] Current and Future Perspectives on Isothermal Nucleic Acid Amplification Technologies for Diagnosing Infections
    Obande, Godwin Attah
    Singh, Kirnpal Kaur Banga
    INFECTION AND DRUG RESISTANCE, 2020, 13 : 455 - 483
  • [30] Research Progress in Application of Isothermal Nucleic Acid Amplification Technology in Food Safety
    Guan, Zhao-wei
    Qi, Li-juan
    Zhang, Yu
    Zhang, Xiao-jun
    Guo, Zhi-jun
    Du, Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (04) : 1077 - 1085