Energetic performance optimization of a capacitive deionization system operating with transient cycles and brackish water

被引:79
作者
Demirer, Onur N. [1 ]
Naylor, Rachel M. [1 ]
Perez, Carlos A. Rios [1 ]
Wilkes, Ellen [1 ]
Hidrovo, Carlos [1 ]
机构
[1] Univ Texas Austin, Austin, TX 78712 USA
关键词
Capacitive deionization; Performance; Energetic analysis; CARBON ELECTRODES; NACL SOLUTIONS; DESALINATION;
D O I
10.1016/j.desal.2013.01.014
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Water desalination using capacitive deionization (CDI) has been a recent topic of intense research as a novel technique for water desalination, capable of returning a fraction of the input energy during the regeneration of nanoporous electrodes used for ion adsorption. Usually, a set of consecutive and alternating desalination-regeneration processes is conducted to evaluate the performance of this type of systems under different operational conditions (applied electric potential, flow rate, and initial solution concentration). However, the effect of timing for desalination and regeneration processes on the performance of a capacitive deionization system has not been explored yet. This paper analyzes the effect of varying the duration of desalination and regeneration processes on overall system performance for three different salinity levels and three different CDI system sizes. More specifically, the variation in energy recovery ratio, thermodynamic efficiency, and net energy required per moles of salt adsorbed per unit of volume treated are evaluated. To optimize the timing for transient operation, one desalination test was performed until total saturation, which is identified by the outlet concentration returning to inlet concentration. From this experiment, three characteristic times were obtained: one that minimizes the outlet solution concentration, one that gives the highest adsorbed ions per energy input and one that corresponds to maximum average adsorption rate. The results obtained from testing these three timing strategies in an alternating desalination-regeneration process suggest the existence of different optimal operational points, depending on the specific needs, such as maximum desalination rate or maximum energy efficiency. The methodology presented in this paper can be extended to other operational conditions/systems to optimize their energetic performance. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 26 条
[1]   Multi-effect distillation plants: state of the art [J].
Al-Shammiri, M ;
Safar, M .
DESALINATION, 1999, 126 (1-3) :45-59
[2]   Capacitive deionization as an electrochemical means of saving energy and delivering clean water. Comparison to present desalination practices: Will it compete? [J].
Anderson, Marc A. ;
Cudero, Ana L. ;
Palma, Jesus .
ELECTROCHIMICA ACTA, 2010, 55 (12) :3845-3856
[3]  
Atkins P.W., 2006, Physical Chemistry, V8
[4]  
Bejan A., 2006, ADV ENG THERMODYNAMI
[5]   Capacitive Deionization of NaCl Solutions at Non-Steady-State Conditions: Inversion Functionality of the Carbon Electrodes [J].
Bouhadana, Yaniv ;
Avraham, Eran ;
Noked, Malachi ;
Ben-Tzion, Moshe ;
Soffer, Abraham ;
Aurbach, Doron .
JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (33) :16567-16573
[6]   A control system for operating and investigating reactors: The demonstration of parasitic reactions in the water desalination by capacitive de-ionization [J].
Bouhadana, Yaniv ;
Ben-Tzion, Moshe ;
Soffer, Abraham ;
Aurbach, Doron .
DESALINATION, 2011, 268 (1-3) :253-261
[7]  
C.o.A.D. Technology and N.R. Council, 2008, DES NAT PERSP
[8]  
Clifton R. L., 2012, 10 INT C NAN MICR MI, P9
[9]  
Demirer O.N., ASME J FLUI IN PRESS, DOI [10.1115/1.4023294, DOI 10.1115/1.4023294]
[10]   Continuous capacitive deionization-electrodialysis reversal through electrostatic shielding for desalination and deionization of water [J].
Dermentzis, Konstantinos ;
Ouzounis, Konstantinos .
ELECTROCHIMICA ACTA, 2008, 53 (24) :7123-7130