In Vivo Dual-Modal Photoacoustic and Ultrasound Imaging of Sentinel Lymph Nodes Using a Solid-State Dye Laser System

被引:15
作者
Han, Moongyu [1 ]
Choi, Wonseok [1 ]
Ahn, Joongho [1 ]
Ryu, Hanyoung [2 ]
Seo, Youngseok [2 ]
Kim, Chulhong [1 ]
机构
[1] Pohang Univ Sci & Technol POSTECH, Dept Elect Engn Creat IT Engn & Mech Engn, Pohang 37673, South Korea
[2] Wontech Co Ltd, R&D Ctr, Daejeon 34028, South Korea
基金
新加坡国家研究基金会;
关键词
photoacoustic imaging; sentinel lymph node biopsy; solid state dye; methylene blue; IDENTIFICATION; NANOPARTICLES; TOMOGRAPHY; RESONANCE; BIOPSY; CANCER; PROBE;
D O I
10.3390/s20133714
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoacoustic imaging (PAI) is being actively investigated as a non-invasive and non-radioactive imaging technique for sentinel lymph node (SLN) biopsy. By taking advantage of optical and ultrasound imaging, PAI probes SLNs non-invasively with methylene blue (MB) in both live animals and breast cancer patients. However, these PAI systems have limitations for widespread use in clinics and commercial marketplaces because the lasers used by the PAI systems, e.g., tunable liquid dye laser systems and optical parametric oscillator (OPO) lasers, are bulky in size, not economical, and use risky flammable and toxic liquid dyes. To overcome these limitations, we are proposing a novel dual-modal photoacoustic and ultrasound imaging system based on a solid-state dye laser (SD-PAUSI), which is compact, convenient, and carries far less risk of flammability and toxicity. Using a solid-state dye handpiece that generates 650-nm wavelength, we successfully imaged the MB tube positioned deeply (similar to 3.9 cm) in chicken breast tissue. The SLNs were also photoacoustically detected in the in vivo rats beneath a 2.2-cm-thick layer of chicken breast, which is deeper than the typical depth of SLNs in humans (1.2 +/- 0.5 cm). Furthermore, we showed the multispectral capability of the PAI by switching the dye handpiece, in which the MB-dyed SLN was selectively highlighted from the surrounding vasculature. These results demonstrated the great potential of the SD-PAUSI as an easy but effective modality for SLN detection.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 47 条
[1]   Multimodal sentinel lymph node mapping with single-photon emission computed tomography (SPECT)/computed tomography (CT) and photoacoustic tomography [J].
Akers, Walter J. ;
Edwards, W. Barry ;
Kim, Chulhong ;
Xu, Baogang ;
Erpelding, Todd N. ;
Wang, Lihong V. ;
Achilefu, Samuel .
TRANSLATIONAL RESEARCH, 2012, 159 (03) :175-181
[2]   Noninvasive Photoacoustic and Fluorescence Sentinel Lymph Node Identification using Dye-Loaded Perfluorocarbon Nanoparticles [J].
Akers, Walter J. ;
Kim, Chulhong ;
Berezin, Mikhail ;
Guo, Kevin ;
Fuhrhop, Ralph ;
Lanza, Gregory M. ;
Fischer, Georg M. ;
Daltrozzo, Ewald ;
Zumbusch, Andreas ;
Cai, Xin ;
Wang, Lihong V. ;
Achilefu, Samuel .
ACS NANO, 2011, 5 (01) :173-182
[3]   Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer, and other potential cancers [J].
Alazraki, NP ;
Eshima, D ;
Eshima, LA ;
Herda, SC ;
Murray, DR ;
Vansant, JP ;
Taylor, AT .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (01) :55-67
[4]  
[Anonymous], 2000, Z1361 ANSI
[5]   Super Wide-Field Photoacoustic Microscopy of Animals and Humans <italic>In Vivo</italic> [J].
Baik, Jin Woo ;
Kim, Jin Young ;
Cho, Seonghee ;
Choi, Seongwook ;
Kim, Jongbeom ;
Kim, Chulhong .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (04) :975-984
[6]  
Balslev S., 2006, POLYM DYE LASERS
[7]  
Bell A G, 1880, Science, V1, P130, DOI 10.1126/science.os-1.12.130
[8]   In vivo label-free functional photoacoustic monitoring of ischemic reperfusion [J].
Bi, Renzhe ;
Dinish, U. S. ;
Goh, Chi Ching ;
Imai, Toru ;
Moothanchery, Mohesh ;
Li, Xiuting ;
Kim, Jin Young ;
Jeon, Seungwan ;
Pu, Yang ;
Kim, Chulhong ;
Ng, Lai Guan ;
Wang, Lihong V. ;
Olivo, Malini .
JOURNAL OF BIOPHOTONICS, 2019, 12 (07)
[9]   A dual modal silver bumpy nanoprobe for photoacoustic imaging and SERS multiplexed identification of in vivo lymph nodes [J].
Cha, Myeong Geun ;
Lee, Seunghyun ;
Park, Sungjo ;
Kang, Homan ;
Lee, Sung Gun ;
Jeong, Cheolhwan ;
Lee, Yoon-Sik ;
Kim, Chulhong ;
Jeong, Dae Hong .
NANOSCALE, 2017, 9 (34) :12556-12564
[10]   3D PHOVIS: 3D photoacoustic visualization studio [J].
Cho, Seonghee ;
Baik, Jinwoo ;
Managuli, Ravi ;
Kim, Chulhong .
PHOTOACOUSTICS, 2020, 18