Thermal performance of ventilated roofs during summer period

被引:83
|
作者
Gagliano, A. [1 ]
Patania, F. [1 ]
Nocera, F. [1 ]
Ferlito, A. [1 ]
Galesi, A. [1 ]
机构
[1] Univ Catania, Fac Engn, Dept Ind & Mech Engn, I-95125 Catania, Italy
关键词
Ventilated roof; Heat fluxes; Energy saving; ENERGY ANALYSIS;
D O I
10.1016/j.enbuild.2012.03.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The European Directive 2002/91/EC about the energy performance of buildings aims to achieve minimum standards on the energy performance both of new and existing buildings that are subject to major renovation. The improvement of "building performance requirements" and the development of new strategies for "very low energy buildings" represent one of the European Directive priority. In fact, an effective saving potential may be obtained reducing the energy consumptions due to the heat flux transmitted through the envelope of residential and commercial buildings. In regions with high level of solar radiation, ventilation of building structures reduces the cooling load during summer period and contributes to the reduction of the energy needs of buildings. During summer period, one of the advantages provided by the ventilation is the reduction of the heat fluxes transmitted by the structures exposed to the solar radiation, thanks to the combined effect of the surfaces shading and of the heat removed by the air flow rate within the ventilated air gap. The objective of this paper has been the analysis of thermal behavior of ventilated roofs characterized by a different placement of thermal layer insulation respect to the air gap. The "Fluent" software has been used with the aim of acquiring a better knowledge of the thermo-fluid dynamic behavior of the air within the ventilated roof and the heat fluxes through ventilated roofs have been calculated. The results of the study show that the ventilation of roofs can reduce significantly the heat fluxes (up to 50%) during summer season. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [31] Experimental investigation of cooling potential of a ventilated cool roof with air gap as a thermal barrier
    V. Vinod Kumar
    Nitin Raut
    Norie Allafi Akeel
    Omar Suliman Zaroog
    Environment, Development and Sustainability, 2023, 25 : 3255 - 3268
  • [32] Exploring energy-saving performance of radiative cooling roofs with a transient heat transfer model
    Liu, Jia
    Xie, Lei
    Wu, Huijun
    Zhang, Guangpeng
    Fang, Can
    Gu, Jiaan
    JOURNAL OF BUILDING ENGINEERING, 2024, 88
  • [33] Computational analysis of blind performance on natural ventilated double skin fasade in winter
    Arabi, Pouria
    Hamidpour, Mahmoud Reza
    Yaghoubi, Mahmood
    Arabi, Faraz
    ENERGY, 2023, 268
  • [34] Effects of key factors on the heat insulation performance of a hollow block ventilated wall
    Huang, Junchao
    Yu, Jinghua
    Yang, Hongxing
    APPLIED ENERGY, 2018, 232 : 409 - 423
  • [35] Performance study of the indirect evaporative air cooler and heat recovery exchanger in air conditioning system during the summer and winter operation
    Anisimov, Sergey
    Pandelidis, Demis
    Jedlikowski, Andrzej
    ENERGY, 2015, 89 : 205 - 225
  • [36] Thermal behaviour of Trombe wall with venetian blind in summer and transition seasons
    Hong, Xiaoqiang
    Leung, Michael K. H.
    He, Wei
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1059 - 1064
  • [37] Effectiveness assessment of different kinds/configurations of phase-change materials (PCM) for improving the thermal performance of lightweight building walls in summer and winter
    Liu, Zu-An
    Hou, Jiawen
    Chen, Yu
    Liu, Zaiqiang
    Zhang, Tao
    Zeng, Qian
    Dewancker, Bart Julien
    Meng, Xi
    Jiang, Guanzhao
    RENEWABLE ENERGY, 2023, 202 : 721 - 735
  • [38] Study on optimal layout and design parameters of ventilated roof for improving building roof thermal performances
    Wang, Haitao
    Chen, Yanyan
    Guo, Chengzhou
    Zhou, Huakun
    Yang, Liu
    ENERGY AND BUILDINGS, 2024, 320
  • [39] Investigation on the thermal performance of rectangular energy storage devices during simultaneous charging and discharging processes
    Deng, D. L.
    Ma, Y.
    Tao, Y.
    Du, R. Q.
    Wang, Y.
    RENEWABLE ENERGY, 2025, 242
  • [40] An analysis of the impact of PMV-based thermal comfort control during heating period: A case study of highly glazed room
    Hawila, Abed Al-Waheed
    Merabtine, Abdelatif
    Chemkhi, Mahdi
    Bennacer, Rachid
    Troussier, Nadege
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 353 - 366