Factors affecting range of motion in total knee arthroplasty using high flexion prosthesis: A prospective study

被引:20
作者
Sancheti, Kantilal H. [1 ]
Sancheti, Parag K. [1 ]
Shyam, Ashok K. [1 ]
Joshi, Rajeev [1 ]
Patil, Kailash [1 ]
Jain, Anubhav [1 ]
机构
[1] Sancheti Inst Orthopaed & Rehabil, Dept Arthroplasty, Pune, Maharashtra, India
关键词
High flex knee prosthesis; range of motion; total knee arthroplasty; FOLLOW-UP; POSTOPERATIVE FLEXION; REPLACEMENT; TRIAL; MOVEMENT; STANDARD; SURGERY; BEARING; PATIENT; DESIGNS;
D O I
10.4103/0019-5413.106901
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: High flexion implants have been reported to provide better range of motion (ROM). The few studies analyzing the factors affecting the ROM are scarce. This study aims to find the factors that affect ROM when using a high flex knee design (INDUS knee). Materials and Methods: Two hundred and fifty three consecutive patients of total knee arthroplasty (TKA) done by using INDUS knee prosthesis between Sept 2008 and Sept 2009 were included in the study. The cases with osteoarthritis (OA) and Rheumatoid arthritis (RA) were included in study. 5 patients were lost to followup and 248 patients (267 knees, 19 bilateral, 221 OA, and 46 RA) were analyzed for the following factors - sex, age, body mass index (BMI), preoperative ROM, flexion deformity, preoperative total knee score and functional score, time of tourniquet release and patella resurfacing. Subgroup classification using above factors was performed and statistical analysis of effect of all the above factors on final knee ROM was done. Assessment was done preoperatively and at 3 months, 6 months and 1 year postoperatively. The final outcome evaluation was done at one year followup. Results: The mean age was 68.2 years (range 40-89 years) with 79 males and 189 females. The mean knee range improved from 97.62 11 degrees to 132 8 degrees. Factors that positively affect ROM of INDUS knee prosthesis at the end of 1 year were preoperative ROM, total knee score and functional score, and diagnosis of osteoarthritis, whereas BMI, preoperative flexion deformity has a negative influence on final flexion at the end of 1 year. Age and gender of the patients, patella resurfacing, and use of two different tourniquet protocols did not affect the final outcome. Conclusion: Preoperative ROM and preoperative functional status are the most important factors affecting final range. Patients should be counseled accordingly and made to understand these factors.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [41] Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty
    Kazunari Ishida
    Nao Shibanuma
    Tomoyuki Matsumoto
    Hiroshi Sasaki
    Koji Takayama
    Akihiko Toda
    Ryosuke Kuroda
    Masahiro Kurosaka
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1741 - 1747
  • [42] Range of Motion of Standard and High-Flexion Cruciate Retaining Total Knee Prostheses
    Minoda, Yukihide
    Aihara, Masaharu
    Sakawa, Akira
    Fukuoka, Shinichi
    Hayakawa, Keiko
    Ohzono, Kenji
    JOURNAL OF ARTHROPLASTY, 2009, 24 (05) : 674 - 680
  • [43] Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty
    Ishida, Kazunari
    Shibanuma, Nao
    Matsumoto, Tomoyuki
    Sasaki, Hiroshi
    Takayama, Koji
    Toda, Akihiko
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (06) : 1741 - 1747
  • [44] Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty
    Matsuzaki, Tokio
    Matsumoto, Tomoyuki
    Muratsu, Hirotsugu
    Kubo, Seiji
    Matsushita, Takehiko
    Kawakami, Yohei
    Ishida, Kazunari
    Oka, Shinya
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (05) : 803 - 808
  • [45] Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty
    Tokio Matsuzaki
    Tomoyuki Matsumoto
    Hirotsugu Muratsu
    Seiji Kubo
    Takehiko Matsushita
    Yohei Kawakami
    Kazunari Ishida
    Shinya Oka
    Ryosuke Kuroda
    Masahiro Kurosaka
    International Orthopaedics, 2013, 37 : 803 - 808
  • [46] Effect of Patellar Thickness on Knee Flexion in Total Knee Arthroplasty: A Biomechanical and Experimental Study
    Abolghasemian, Mansour
    Samiezadeh, Saeid
    Sternheim, Amir
    Bougherara, Habiba
    Barnes, C. Lowry
    Backstein, David J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01) : 80 - 84
  • [47] Evaluation Tibia Rotation in Total Knee Arthroplasty Designed for Deep Knee Flexion Using Knee Kinematics Motion Simulator
    Triwardono, Joko
    Kartika, Ika
    Sutowo, Cahya
    Ciptasari, Nurhayati Indah
    Elvira, Bunga Rani
    Rokhmanto, Fendy
    Asmaria, Talitha
    Purnama, Harry
    Rahyussalim
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2025, 67 : 95 - 107
  • [48] Outcome and Range of Motion Using a High-flexion Cruciate-retaining TKA
    Rosen, Adam S.
    Neville, Lorraine
    Pulido, Pamela A.
    Patil, Shantanu
    Walker, Richard H.
    Copp, Steven N.
    ORTHOPEDICS, 2013, 36 (09) : E1198 - E1202
  • [49] The Role of Surgical Closure Position in Total Knee Arthroplasty: Flexion versus Extension-A Randomized Prospective Study
    Pepe, Murad
    Calisal, Emre
    Kocadal, Onur
    Bicer, Eren
    Taskin, Suhan
    Aktekin, Cem Nuri
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 624 - 629
  • [50] High-flexion total knee arthroplasty: a systematic review
    Murphy, Michael
    Journeaux, Simon
    Russell, Trevor
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 887 - 893