Reliability of Predictors for Screw Cutout in Intertrochanteric Hip Fractures

被引:135
|
作者
De Bruijn, Kirstin [1 ]
den Hartog, Dennis
Tuinebreijer, Wim
Roukema, Gert
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Surg, NL-3000 CA Rotterdam, Netherlands
关键词
TIP-APEX DISTANCE; FIXATION; FAILURE; FEMUR; NAIL;
D O I
10.2106/JBJS.K.00357
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position of the screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We investigated the reliability of the tip apex distance measurement, the Cleveland femoral head dividing system, the three-grade classification system of Baumgaertner for fracture reduction, and the AO classification system as predictors for screw cutout. Methods: All patients with an intertrochanteric hip fracture who were managed with either a dynamic hip screw or a gamma nail between January 2007 and June 2010 were evaluated from our hip trauma database. Results: The tip apex distance measurement was reliable and patients with device cutout had a significantly higher tip apex distance. The agreement between observers with regard to screw position and fracture reduction was moderately reliable. After adjustment for tip apex distance and screw position, A3 fractures were at more risk of cutout compared with A1 fractures. Poor fracture reduction was significantly related with a higher incidence of cutout in univariate analysis, but not in multivariate analysis. Central-inferior and anterior-inferior positions, after adjustment for tip apex distance and screw position, were significantly protective against cutout. Conclusion: To decrease probable risks of cutout, the tip apex distance needs to stay small or the screw needs to be placed central-inferiorly or anterior-inferiorly. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:1266 / 1272
页数:7
相关论文
共 50 条
  • [41] Correlation between Post-Operation Center-Trochanteric Distance (CTD) and Tip Apex Distance (TAD) changes in Intertrochanteric Fractures Treated by Dynamic Hip Screw
    Ebrahimpour, Adel
    Karimi, Amin
    Sadighi, Mehrdad
    Sajjadi, Mohammadreza Minator
    Okhovatpour, Mohammad Ali
    Sabbaghzadeh, Amir
    Zandi, Reza
    TRAUMA MONTHLY, 2019, 24 (06) : 32 - 37
  • [42] Comparison of the Dynamic Hip Screw with the Dynamic Hip External Fixator for Intertrochanteric Fractures: Report of a Randomized Controlled Trial
    Moradi, Ali
    Moradi, Meisam
    Emadzadeh, Maryam
    Bagheri, Farshid
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (06): : 662 - 673
  • [43] The correlation between cutout and eccentric distance (ED) of the cephalic fixator tip in geriatric intertrochanteric fractures with internal fixation
    Yang, Yun-fa
    Huang, Jian-wen
    Gao, Xiao-sheng
    Xu, Zhong-he
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [44] Intertrochanteric Fracture Treated by Dynamic Hip Screw, Aden, Yemen
    Mohsen, Abdulsalam Abdullah Hadi
    WORLD FAMILY MEDICINE, 2021, 19 (09): : 31 - 38
  • [45] Minimally Invasive Versus Conventional Dynamic Hip Screw for the Treatment of Intertrochanteric Fractures in Older Patients
    Zhou, Zhiping
    Zhang, Xingxiang
    Tian, Shoujin
    Wu, Yaogang
    ORTHOPEDICS, 2012, 35 (02) : E244 - E249
  • [46] A comparison of hemiarthroplasty versus dynamic hip screw fixation for intertrochanteric femoral fractures: a systematic review
    Chowdhury, Alex K.
    Townsend, Oliver
    Edwards, Max R.
    HIP INTERNATIONAL, 2023, 33 (04) : 752 - 761
  • [47] Biomechanical Investigation of an Integrated 2-Screw Cephalomedullary Nail Versus a Sliding Hip Screw in Unstable Intertrochanteric Fractures
    Santoni, Brandon G.
    Diaz, Miguel A.
    Stoops, T. Kyle
    Lannon, Sean
    Ali, Ashley
    Sanders, Roy W.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (02) : 82 - 87
  • [48] A new technique for lag screw placement in the dynamic hip screw fixation of intertrochanteric fractures: decreasing radiation time dramatically
    Sheng, Wei-Chao
    Li, Jia-Zhen
    Chen, Sheng-Hua
    Zhong, Shi-Zhen
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 537 - 542
  • [49] Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival
    Fang, Christian
    Gudushauri, Paata
    Wong, Tak-Man
    Lau, Tak-Wing
    Pun, Terence
    Leung, Frankie
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [50] Decision making in the management of malunion and nonunion of intertrochanteric fractures of the hip
    Bhowmick, Kaushik
    Matthai, Thomas
    Boopalan, Perumal Ramaswamy J. V. C.
    Jepegnanam, Thilak S.
    HIP INTERNATIONAL, 2020, 30 (06) : 793 - 798