Quality Metrics for High Order Meshes: Analysis of the Mechanical Simulation of the Heart Beat

被引:20
作者
Lamata, Pablo [1 ,2 ]
Roy, Ishani [1 ]
Blazevic, Bojan [1 ]
Crozier, Andrew [1 ]
Land, Sander [1 ,2 ]
Niederer, Steven A. [1 ]
Hose, D. Rod [3 ]
Smith, Nicolas P. [1 ]
机构
[1] Kings Coll London, Dept Biomed Engn, St Thomas Hosp, London SE1 7EH, England
[2] Univ Oxford, Dept Comp Sci, Oxford OX1 3QD, England
[3] Univ Sheffield, Dept Cardiovasc Sci, Royal Hallamshire Hosp, Sheffield S10 2JF, S Yorkshire, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
Computational cardiac physiology; computational mesh; image registration; mesh quality; mesh stability; MATERIAL PARAMETER-ESTIMATION; 3D; GENERATION;
D O I
10.1109/TMI.2012.2231094
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The quality of a computational mesh is an important characteristic for stable and accurate simulations. Quality depends on the regularity of the initial mesh, and in mechanical simulations it evolves in time, with deformations causing changes in volume and distortion of mesh elements. Mesh quality metrics are therefore relevant for both mesh personalization and the monitoring of the simulation process. This work evaluates the significance, in meshes with high order interpolation, of four quality metrics described in the literature, applying them to analyse the stability of the simulation of the heart beat. It also investigates how image registration and mesh warping parameters affect the quality and stability of meshes. Jacobian-based metrics outperformed or matched the results of coarse geometrical metrics of aspect ratio or orthogonality, although they are more expensive computationally. The stability of simulations of a complete heart cycle was best predicted with a specificity of 61%, sensitivity of 85%, and only nominal differences were found changing the intra-element and per-element combination of quality values. A compromise between fitting accuracy and mesh stability and quality was found. Generic geometrical quality metrics have a limited success predicting stability, and an analysis of the simulation problem may be required for an optimal definition of quality.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 27 条
[1]  
[Anonymous], 2000, FINITE ELEMENT METHO
[2]   Mesh movement and metamorphosis [J].
Baker, TJ .
ENGINEERING WITH COMPUTERS, 2002, 18 (03) :188-198
[3]   Efficient computational fluid dynamics mesh generation by image registration [J].
Barber, D. C. ;
Oubel, E. ;
Frangi, A. F. ;
Hose, D. R. .
MEDICAL IMAGE ANALYSIS, 2007, 11 (06) :648-662
[4]  
Casero R, 2010, LECT NOTES COMPUT SC, V6364, P75, DOI 10.1007/978-3-642-15835-3_8
[5]   Modelling cardiac mechanical properties in three dimensions [J].
Costa, KD ;
Holmes, JW ;
McCulloch, AD .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2001, 359 (1783) :1233-1250
[6]   The mesh-matching algorithm:: an automatic 3D mesh generator for finite element structures [J].
Couteau, B ;
Payan, Y ;
Lavallée, S .
JOURNAL OF BIOMECHANICS, 2000, 33 (08) :1005-1009
[7]   Towards curvilinear meshing in 3D: the case of quadratic simplices [J].
Dey, S ;
O'Bara, RM ;
Shephard, MS .
COMPUTER-AIDED DESIGN, 2001, 33 (03) :199-209
[8]  
Fernandez JW, 2004, BIOMECH MODEL MECHAN, V2, P139, DOI [10.1007/s10237-003-0036-1, 10.1007/S10237-003-0036-1]
[9]   Effects of biventricular pacing and scar size in a computational model of the failing heart with left bundle branch block [J].
Kerckhoffs, Roy C. P. ;
McCulloch, Andrew D. ;
Omens, Jeffrey H. ;
Mulligan, Lawrence J. .
MEDICAL IMAGE ANALYSIS, 2009, 13 (02) :362-369
[10]  
Knupp PM, 2000, INT J NUMER METH ENG, V48, P401, DOI 10.1002/(SICI)1097-0207(20000530)48:3<401::AID-NME880>3.0.CO