Anterior Chamber Angle Evaluation with Fourier-Domain Optical Coherence Tomography

被引:20
作者
Bald, Matthew
Li, Yan
Huang, David [1 ]
机构
[1] Oregon Hlth & Sci Univ, Ctr Ophthalm Opt & Lasers, Casey Eye Inst, Portland, OR 97239 USA
关键词
SWEPT SOURCE; IN-VIVO; SEGMENT; CLOSURE;
D O I
10.1155/2012/103704
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
New advances in anterior segment optical coherence tomography (OCT) technology development allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Fourier-domain (FD) OCT instruments working at 840 nm can reliably identify fine angle structures such as the Schwalbe's line. This paper demonstrates quantitative angle assessment with 840nm FD-OCT and provides diagnostic cutoff values for occludable angle detection. This is useful for angle closure glaucoma diagnosis and management. Moreover, 840nm FD-OCT is a useful tool for postsurgical evaluation in glaucoma patients.
引用
收藏
页数:5
相关论文
共 28 条
[1]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]  
Dorairaj Syril, 2007, Trans Am Ophthalmol Soc, V105, P99
[4]  
Fujimoto J., 2010, IMAGING EYE FRONT BA
[5]   Noninvasive Observations of Peripheral Angle in Eyes After Penetrating Keratoplasty Using Anterior Segment Fourier-Domain Optical Coherence Tomography [J].
Fukuda, Reina ;
Usui, Tomohiko ;
Tomidokoro, Atsuo ;
Mishima, Koichi ;
Matagi, Naomi ;
Miyai, Takashi ;
Amano, Shiro ;
Araie, Makoto .
CORNEA, 2012, 31 (03) :259-263
[6]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]  
Huang D., 2009, OPHTHALMOLOGY MANAGE, V13, P33
[9]  
Huang David, 2004, Ophthalmol Clin North Am, V17, P1, DOI 10.1016/S0896-1549(03)00103-2
[10]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589