The BOLD sensitivity of rapid steady-state sequences

被引:10
作者
Scheffler, Klaus [1 ,2 ]
Heule, Rahel [1 ]
Baez-Yanez, Mario G. [1 ,3 ]
Kardatzki, Bernd [2 ]
Lohmann, Gabriele [1 ,2 ]
机构
[1] Max Planck Inst Biol Cybernet, High Field MR Ctr, Tubingen, Germany
[2] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
[3] Univ Tubingen, Grad Training Ctr Neurosci, Tubingen, Germany
关键词
blood oxygenation; diffusion; steady-state free precession; vessel size; SPIN-ECHO FMRI; GRADIENT-ECHO; 7; T; INTRAVASCULAR CONTRIBUTION; VISUAL-CORTEX; BALANCED SSFP; HUMAN BRAIN; BLOOD; DIFFUSION; MODEL;
D O I
10.1002/mrm.27585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Relaxation and dephasing of water protons embedded in a vascular network is driven by local magnetic field inhomogeneities around deoxygenated blood vessels. These effects strongly depend on the relation between mean diffusion length and diameter of blood vessels, as well as on the chosen imaging sequence. In this work, the BOLD sensitivity of steady-state sequences as a function of vessel size, field strength, and sequence parameters are analyzed. Methods: Steady-state magnetization within a network of artificial cylinders is simulated with Monte Carlo methods for different coherence pathways. In addition, measurements on microspheres were performed to confirm theoretical results. Results: Simulations and phantom results demonstrate a vessel size-dependent signal attenuation effect of all coherence pathways. Both the FID and ECHO pathways show a signal profile similar to spin echo sequences where in the static dephasing regime the effect of larger vessels is suppressed. Conclusion: The BOLD effect measured in steady-state sequences is most sensitive to microvessels and might therefore be closer to the underlying neuronal event compared to gradient echo sequence
引用
收藏
页码:2526 / 2535
页数:10
相关论文
共 50 条
  • [31] Sensitivity of diffusion weighted steady state free precession to anisotropic diffusion
    McNab, Jennifer A.
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 405 - 413
  • [32] Modified steady-state free precession pulse sequences for the detection of pure nuclear quadrupole resonance
    Rudakov, TN
    Mikhaltsevitch, VT
    Flexman, JH
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2004, 25 (1-3) : 94 - 98
  • [33] QUASI STEADY-STATE HURRICANES REVISITED
    Persing, John
    Montgomery, Michael T.
    Smith, Roger K.
    McWilliams, James C.
    TROPICAL CYCLONE RESEARCH AND REVIEW, 2019, 8 (01) : 1 - 17
  • [34] Rheology of draining steady-state foams
    Soller, Raenell
    Koehler, Stephan A.
    PHYSICAL REVIEW E, 2009, 80 (02)
  • [35] A GENERALIZED STEADY-STATE GROWTH THEOREM
    Irmen, Andreas
    MACROECONOMIC DYNAMICS, 2018, 22 (04) : 779 - 804
  • [36] Optimization of flip angle and radiofrequency pulse phase to maximize steady-state magnetization in three-dimensional missing pulse steady-state free precession
    Kobayashi, Naoharu
    NMR IN BIOMEDICINE, 2024, 37 (06)
  • [37] A steady-state theory for processive cellulases
    Cruys-Bagger, Nicolaj
    Elmerdahl, Jens
    Praestgaard, Eigil
    Borch, Kim
    Westh, Peter
    FEBS JOURNAL, 2013, 280 (16) : 3952 - 3961
  • [38] A STEADY-STATE MODEL FOR CAROTENOID METABOLISM
    SHLYGIN, VV
    ARNAUTOV, LN
    MAKSIMOV, GV
    BIOCHEMISTRY-MOSCOW, 1992, 57 (07) : 735 - 744
  • [39] Steady-state growth and the elasticity of substitution
    Irmen, Andreas
    JOURNAL OF ECONOMIC DYNAMICS & CONTROL, 2011, 35 (08) : 1215 - 1228
  • [40] On the Steady-State Properties of Actual Flip Angle Imaging (AFI)
    Nehrke, Kay
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 84 - 92