A brief report: The use of high-frequency oscillatory ventilation for severe pulmonary contusion

被引:15
作者
Funk, Duane J. [2 ]
Luian, Eugenio [3 ]
Moretti, Eugene W. [2 ]
Davies, John [4 ]
Young, Christopher C. [2 ]
Patel, Mayur B. [1 ]
Vaslef, Steven N. [1 ]
机构
[1] Duke Univ, Med Ctr, Sect Trauma & Crit Care, Div Gen Surg,Dept Surg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Div Crit Care Med, Dept Anesthesiol, Durham, NC 27710 USA
[3] USN, Div Crit Care Med, Dept Anesthesiol, Med Ctr, San Diego, CA 92152 USA
[4] Duke Univ, Med Ctr, Div Pulm Med, Durham, NC 27710 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 65卷 / 02期
关键词
high frequency oscillatory ventilation; acute respiratory distress syndrome; pulmonary contusion; linear mixed model;
D O I
10.1097/TA.0b013e31817f283f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Severe pulmonary contusions are a common cause of acute respiratory distress syndrome (ARDS) and are associated with significant morbidity. High frequency oscillatory ventilation (HFOV) is a ventilatory mode that employs a lung protective strategy consistent with the ARDSNet low tidal volume ventilation strategy and may result in reduced morbidity. The objective of this report is to examine the impact of HFOV on blunt trauma patients with severe pulmonary contusions who failed or were at a high risk of failing conventional mechanical ventilation. Methods: We undertook a retrospective chart review of all patients at our institution who received HFOV for severe pulmonary contusions. Patients were placed on HFOV when their mean airway pressure (mP(aw)) surpassed 30 cm H(2)O and their FIO(2) was greater than 0.6. Baseline demographic data including injury severity score (ISS), length of time requiring HFOV, total ventilator days, and inhospital mortality were collected. Serial determinations of oxygenation index (OI) and the PAO(2)/FIO(2) ratio (P/F) were made up to 72 hours after initiation of HFOV. A linear mixed model was used to analyze the slope (beta) of the regression line of P/F versus time and that of OI versus time. Results: Seventeen patients were identified who underwent HFOV for ARDS due primarily to pulmonary contusions. Mean ISS was 36.6, mean APACHE II score was 21.7, and the mean time before initiation of HFOV was 2.0 days. P/F increased significantly after HFOV was initiated (beta = 12. 1; 95 % confidence interval 7.9 to 16.4,p < 0.001). OI significantly decreased after HFOV implementation beta = -1.8; 95% confidence interval -2.3 to -1.3, p < 0.001). Mortality rate was 17.6%. Conclusions: The early use of HFOV appears to be safe and efficacious in blunt trauma patients sustaining pulmonary contusions, and results in a rapid improvement in OI and the P/F ratio.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 33 条
[1]   Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome [J].
Amato, MBP ;
Barbas, CSV ;
Medeiros, DM ;
Magaldi, RB ;
Schettino, GDP ;
Lorenzi, G ;
Kairalla, RA ;
Deheinzelin, D ;
Munoz, C ;
Oliveira, R ;
Takagaki, TY ;
Carvalho, CRR .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) :347-354
[2]   High frequency oscillatory ventilation in adult patients with acute respiratory distress syndrome - a retrospective study [J].
Andersen, FA ;
Guttormsen, AB ;
Flaatten, HK .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (09) :1082-1088
[3]   RISK-FACTORS FOR EARLY-ONSET PNEUMONIA IN TRAUMA PATIENTS [J].
ANTONELLI, M ;
MORO, ML ;
CAPELLI, O ;
DEBLASI, RA ;
DERRICO, RR ;
CONTI, G ;
BUFI, M ;
GASPARETTO, A .
CHEST, 1994, 105 (01) :224-228
[4]   PROSPECTIVE, RANDOMIZED COMPARISON OF HIGH-FREQUENCY OSCILLATORY VENTILATION AND CONVENTIONAL MECHANICAL VENTILATION IN PEDIATRIC RESPIRATORY-FAILURE [J].
ARNOLD, JH ;
HANSON, JH ;
TOROFIGUERO, LO ;
GUTIERREZ, J ;
BERENS, RJ ;
ANGLIN, DL .
CRITICAL CARE MEDICINE, 1994, 22 (10) :1530-1539
[5]   REPORT OF THE AMERICAN-EUROPEAN CONSENSUS CONFERENCE ON ACUTE RESPIRATORY-DISTRESS SYNDROME - DEFINITIONS, MECHANISMS, RELEVANT OUTCOMES, AND CLINICAL-TRIAL COORDINATION [J].
BERNARD, GR ;
ARTIGAS, A ;
BRIGHAM, KL ;
CARLET, J ;
FALKE, K ;
HUDSON, L ;
LAMY, M ;
LEGALL, JR ;
MORRIS, A ;
SPRAGG, R ;
Cochin, B ;
Lanken, PN ;
Leeper, KV ;
Marini, J ;
Murray, JF ;
Oppenheimer, L ;
Pesenti, A ;
Reid, L ;
Rinaldo, J ;
Villar, J ;
van Asbeck, BS ;
Dhainaut, JF ;
Mancebo, J ;
Matthay, M ;
Meyrick, B ;
Payen, D ;
Perret, C ;
Fowler, AA ;
Schaller, MD ;
Hudson, LD ;
Hyers, T ;
Knaus, W ;
Matthay, R ;
Pinsky, M ;
Bone, RC ;
Bosken, C ;
Johanson, WG ;
Lewandowski, K ;
Repine, J ;
Rodriguez-Roisin, R ;
Roussos, C ;
Antonelli, MA ;
Beloucif, S ;
Bihari, D ;
Burchardi, H ;
LeMaire, F ;
Montravers, P ;
Petty, TL ;
Robotham, J ;
Zapol, W .
JOURNAL OF CRITICAL CARE, 1994, 9 (01) :72-81
[6]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[7]   Early clinical experience with high-frequency oscillatory ventilation for ARDS in adult burn patients [J].
Cartotto, R ;
Cooper, AB ;
Esmond, JR ;
Gomez, M ;
Fish, JS ;
Smith, T .
JOURNAL OF BURN CARE & REHABILITATION, 2001, 22 (05) :325-333
[8]  
Chan Kenneth P W, 2005, Crit Care Med, V33, pS170, DOI 10.1097/01.CCM.0000155915.97462.80
[9]  
Claridge JA, 1999, AM SURGEON, V65, P1092
[10]  
CLARK RH, 1992, PEDIATRICS, V89, P5