Validation of magneto-inertial measuring units for measuring hip joint angles

被引:18
作者
Horenstein, Rachel E. [1 ]
Lewis, Cara L. [2 ]
Yan, Sherry [2 ]
Halverstadt, Anne [2 ]
Shefelbine, Sandra J. [1 ,3 ]
机构
[1] Northeastern Univ, Dept Mech & Ind Engn, Boston, MA 02115 USA
[2] Boston Univ, Dept Phys Therapy & Athlet Training, Boston, MA 02215 USA
[3] Northeastern Univ, Dept Bioengn, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
Inertial measurement units; Hip motion; Pervasive sensing; COORDINATE SYSTEM; AMBULATORY MEASUREMENT; MOTION; KINEMATICS; SENSORS; REPRESENTATION; ACCURACY; ATTITUDE; ANKLE; KNEE;
D O I
10.1016/j.jbiomech.2019.05.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Camera-based motion capture systems are the current gold standard for motion analysis. However, the use of wireless inertial sensor-based systems is increasing in popularity, largely due to convenient portability. The purpose of this study was to validate the use of wireless inertial sensors for measuring hip joint motion with a functional calibration requiring only one motion (walking) and neutral standing. Data were concurrently collected using a 10-camera motion capture system and a wireless inertial sensor based system. Hip joint angles were measured for 10 participants during walking, jumping jack, and bilateral squat tasks and for a subset (n = 5) a jump turn task. Camera-based system hip joint angles were calculated from retro-reflective marker positions and sensor-based system angles were calculated in MATLAB using the sensor output quaternions. Most hip joint angles measured with the sensor-based system were within 6 degrees of angles measured with the camera motion capture system. Accurate measurement of motion outside of a laboratory setting has broad implications for diagnosing movement abnormalities, monitoring sports performance, and assessing rehabilitation progress. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 32 条
  • [21] Identification of Noise Covariance Matrices to Improve Orientation Estimation by Kalman Filter
    Nez, Alexis
    Fradet, Laetitia
    Marin, Frederic
    Monnet, Tony
    Lacouture, Patrick
    [J]. SENSORS, 2018, 18 (10)
  • [22] An inertial and magnetic sensor based technique for joint angle measurement
    O'Donovan, Karol J.
    Kamnik, Roman
    O'Keeffe, Derek T.
    Lyons, Gerard M.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (12) : 2604 - 2611
  • [23] Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis
    Palermo, Eduardo
    Rossi, Stefano
    Marini, Francesca
    Patane, Fabrizio
    Cappa, Paolo
    [J]. MEASUREMENT, 2014, 52 : 145 - 155
  • [24] Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment
    Piazza, SJ
    Cavanagh, PR
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (08) : 1029 - 1034
  • [25] Joint kinematics estimate using wearable inertial and magnetic sensing modules
    Picerno, Pietro
    Cereatti, Andrea
    Cappozzo, Aurelio
    [J]. GAIT & POSTURE, 2008, 28 (04) : 588 - 595
  • [26] Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation
    Roetenberg, D
    Luinge, HJ
    Baten, CTM
    Veltink, PH
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (03) : 395 - 405
  • [27] Quaternion-based extended Kalman filter for determining orientation by inertial and magnetic sensing
    Sabatini, Angelo M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1346 - 1356
  • [28] Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed
    Spain, R. I.
    George, R. J. St.
    Salarian, A.
    Mancini, M.
    Wagner, J. M.
    Horak, F. B.
    Bourdette, D.
    [J]. GAIT & POSTURE, 2012, 35 (04) : 573 - 578
  • [29] Three Dimensional Gait Analysis Using Wearable Acceleration and Gyro Sensors Based on Quaternion Calculations
    Tadano, Shigeru
    Takeda, Ryo
    Miyagawa, Hiroaki
    [J]. SENSORS, 2013, 13 (07): : 9321 - 9343
  • [30] Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
    Takeda, Ryo
    Lisco, Giulia
    Fujisawa, Tadashi
    Gastaldi, Laura
    Tohyama, Harukazu
    Tadano, Shigeru
    [J]. SENSORS, 2014, 14 (12): : 23230 - 23247