Temperature increases associated with polymerization of irradiated PAG dosimeters

被引:35
作者
Salomons, GJ
Park, YS
McAuley, KB
Schreiner, LJ
机构
[1] Kingston Reg Canc Ctr, Kingston, ON K7L 5P9, Canada
[2] Queens Univ, Dept Chem Engn, Kingston, ON K7L 3N6, Canada
[3] Queens Univ, Dept Phys, Kingston, ON K7L 3N6, Canada
[4] Queens Univ, Dept Oncol, Kingston, ON K7L 3N6, Canada
关键词
D O I
10.1088/0031-9155/47/9/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyacrylamide gel (PAG) dosimeters show considerable promise as three-dimensional dosimeters for the verification of complex dose distributions associated with conformal therapy. However, the potential of PAG dosimeters has not yet been borne out in clinical practice and it is apparent that basic investigations of these dosimeters are still required. The polymerization reactions in PAG dosimeters are exothermic and the heat given off by the reactions may influence polymerization reaction kinetics. We report the results of in situ measurements of local temperature increases in irradiated PAG resulting from heat generated by the radiation-induced exothermic polymerization reactions. Temperature changes proportional to the absorbed dose were observed in the irradiated gels, reaching a maximum of 12 degreesC under high-dose conditions, depending on the thermal boundary conditions. This has practical implications, for example, using small vials of PAG to calibrate large phantoms may not be appropriate since temperature differences during irradiation between the calibration vials and phantom may alter the morphology and quantity of the polymer formed, even when irradiated to the same dose. The inhibition of radiation-induced polymerization associated with low-level oxygen contamination is manifested by a delay in the onset of temperature rise during irradiation. The observed temperature changes are used to estimate the percentage conversion of double bonds from the bis/acrylamide monomers by polymerization reactions.
引用
收藏
页码:1435 / 1448
页数:14
相关论文
共 40 条
[1]  
[Anonymous], 1995, FUNDAMENTALS HEAT MA
[2]  
AUDET C, 1996, P 42 ANN C CAN ORG M, P196
[3]  
AUDET C, 1995, THESIS MCGILL U
[4]   Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry [J].
Baldock, C ;
Rintoul, L ;
Keevil, SF ;
Pope, JM ;
George, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3617-3627
[5]   Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry [J].
Baldock, C ;
Burford, RP ;
Billingham, N ;
Wagner, GS ;
Patval, S ;
Badawi, RD ;
Keevil, SF .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) :695-702
[6]  
BALDOCK C, 1999, P 1 INT WORKSH RAD T, P99
[7]   THERMODYNAMIC PARAMETERS OF POLYACRYLAMIDES IN WATER [J].
DAY, JC ;
ROBB, ID .
POLYMER, 1981, 22 (11) :1530-1533
[8]  
De Deene Y, 2000, MAGN RESON MED, V43, P116, DOI 10.1002/(SICI)1522-2594(200001)43:1<116::AID-MRM14>3.0.CO
[9]  
2-5
[10]  
De Deene Y, 2000, PHYS MED BIOL, V45, P859, DOI 10.1088/0031-9155/45/4/304