A ratiometric fluorescent sensor with a large Stokes shift for imaging zinc ions in living cells

被引:175
作者
Xue, Lin [1 ,3 ]
Liu, Chun [2 ]
Jiang, Hua [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, CAS Key Lab Photochem, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
[2] Dalian Univ Technol, Dept Chem Engn, State Key Lab Fine Chem, Dalian 116012, Peoples R China
[3] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
关键词
BIOLOGICAL APPLICATIONS; INTRACELLULAR ZINC; CHARGE-TRANSFER; PROBE; ZN2+; DESIGN; CHEMOSENSORS; MICROSCOPY; COUMARIN; PLATFORM;
D O I
10.1039/b814501f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The ratiometric fluorescent sensor FQ1 based on furoquinoline has been designed and synthesized, and not only exhibits a large Stokes shift of 199 nm in a mixture of C2H5OH-H2O (v/v = 8 : 2, 10 mM Tris-HCl, pH = 7.3), but can selectively detect zinc ions in the presence of competing metal ions with a red-shift of 75 nm; moreover, cell stain experiments show that FQ1 can readily reveal a change in intracellular Zn2+.
引用
收藏
页码:1061 / 1063
页数:3
相关论文
共 32 条
[1]   A ratiometric fluorescence probe for selective visual sensing of Zn2+ [J].
Ajayaghosh, A ;
Carol, P ;
Sreejith, S .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (43) :14962-14963
[2]  
[Anonymous], 2003, Introduction to Biophotonics
[3]   The galvanization of biology: A growing appreciation for the roles of zinc [J].
Berg, JM ;
Shi, YG .
SCIENCE, 1996, 271 (5252) :1081-1085
[4]   Fluorescent sensors for Zn2+ based on a fluorescein platform:: Synthesis, properties and intracellular distribution [J].
Burdette, SC ;
Walkup, GK ;
Spingler, B ;
Tsien, RY ;
Lippard, SJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (32) :7831-7841
[5]   Ratiometric and near-infrared molecular probes for the detection and imaging of zinc ions [J].
Carol, Priya ;
Sreejith, Sivaramapanicker ;
Ajayaghosh, Ayyappanpillai .
CHEMISTRY-AN ASIAN JOURNAL, 2007, 2 (03) :338-348
[6]   A tautomeric zinc sensor for ratiometric fluorescence imaging: Application to nitric oxide-induced release of intracellular zinc [J].
Chang, CJ ;
Jaworski, J ;
Nolan, EM ;
Sheng, M ;
Lippard, SJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (05) :1129-1134
[7]   Ion sensing coupled to resonance energy transfer: A highly selective and sensitive ratiometric fluorescent chemosensor for Ag(I) by a modular approach [J].
Coskun, A ;
Akkaya, EU .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (30) :10464-10465
[8]   Synthetic fluorescent sensors for studying the cell biology of metals [J].
Domaille, Dylan W. ;
Que, Emily L. ;
Chang, Christopher J. .
NATURE CHEMICAL BIOLOGY, 2008, 4 (03) :168-175
[9]  
FREDERICKSON CJ, 1989, INT REV NEUROBIOL, V31, P145
[10]   Development of a zinc ion-selective luminescent lanthanide chemosensor for biological applications [J].
Hanaoka, K ;
Kikuchi, K ;
Kojima, H ;
Urano, Y ;
Nagano, T .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (39) :12470-12476