Measurement of Gaussian laser beam radius using the knife-edge technique: improvement on data analysis

被引:125
作者
de Araujo, Marcos A. C. [1 ]
Silva, Rubens [1 ,2 ]
de Lima, Emerson [1 ]
Pereira, Daniel P. [1 ,3 ]
de Oliveira, Paulo C. [1 ]
机构
[1] Univ Fed Paraiba, Dept Fis, BR-58051970 Joao Pessoa, Paraiba, Brazil
[2] Fed Univ Para, ICEN, Fac Fis, BR-66075110 Belem, Para, Brazil
[3] Ctr Fed Educacao Tecnol Para, BR-66093020 Belem, Para, Brazil
关键词
PARAMETERS; WAIST; INVERSION; DIAMETER; WIDTH; LENS;
D O I
10.1364/AO.48.000393
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We revisited the well known Khosrofian and Garetz inversion algorithm [Appl. Opt. 22, 3406-3410 (1983)] that was developed to analyze data obtained by the application of the traveling knife-edge technique. We have analyzed the approximated fitting function that was used for adjusting their experimental data and have found that it is not optimized to work with a full range of the experimentally-measured data. We have numerically calculated a new set of coefficients, which makes the approximated function suitable for a HI experimental range, considerably improving the accuracy of the measurement of a radius of a focused Gaussian laser beam. (c) 2009 Optical Society of America
引用
收藏
页码:393 / 396
页数:4
相关论文
共 15 条
[1]   TECHNIQUE FOR FAST MEASUREMENT OF GAUSSIAN LASER BEAM PARAMETERS [J].
ARNAUD, JA ;
HUBBARD, WM ;
MANDEVILLE, GD ;
CLAVIERE, BD ;
FRANKE, EA ;
FRANKE, JM .
APPLIED OPTICS, 1971, 10 (12) :2775-+
[2]   Determination of beam width and quality for pulsed lasers using the knife-edge method [J].
Bachmann, L ;
Zezell, DM ;
Maldonado, EP .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2003, 31 (01) :47-52
[3]   MODE-MISMATCHED THERMAL LENS DETERMINATION OF TEMPERATURE-COEFFICIENT OF OPTICAL-PATH LENGTH IN SODA LIME GLASS AT DIFFERENT WAVELENGTHS [J].
BAESSO, ML ;
SHEN, J ;
SNOOK, RD .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (08) :3732-3737
[4]   BEAM WAIST AND M(2) MEASUREMENT USING A FINITE SLIT [J].
CHAPPLE, PB .
OPTICAL ENGINEERING, 1994, 33 (07) :2461-2466
[5]   MEASUREMENT OF A GAUSSIAN LASER-BEAM DIAMETER THROUGH THE DIRECT INVERSION OF KNIFE-EDGE DATA [J].
KHOSROFIAN, JM ;
GARETZ, BA .
APPLIED OPTICS, 1983, 22 (21) :3406-3410
[6]   KNIFE-EDGE PROFILING OF Q-SWITCHED ND-YAG LASER-BEAM AND WAIST [J].
MAUCK, M .
APPLIED OPTICS, 1979, 18 (05) :599-600
[7]   MEASUREMENT OF GAUSSIAN-BEAM PARAMETERS [J].
MCCALLY, RL .
APPLIED OPTICS, 1984, 23 (14) :2227-2227
[8]   DETERMINATION OF WAIST PARAMETERS OF A GAUSSIAN-BEAM [J].
NEMOTO, S .
APPLIED OPTICS, 1986, 25 (21) :3859-3863
[9]   ABEL INVERSION OF KNIFE-EDGE DATA FROM RADIALLY SYMMETRICAL PULSED LASER-BEAMS [J].
OCONNELL, RM ;
VOGEL, RA .
APPLIED OPTICS, 1987, 26 (13) :2528-2532
[10]   LASER-BEAM DISTRIBUTION IN FOCAL REGION [J].
SHAYLER, PJ .