Optimization of the soft X-ray transmission microscopy beamline at the ALBA light source

被引:1
|
作者
Sorrentino, Andrea [1 ]
Pereiro, Eva [1 ]
Valcarcel, Ricardo [1 ]
Ferrer, Salvador [1 ]
Nicolas, Josep [1 ]
机构
[1] ALBA Synchrotron, Cerdanyola Del Valles 08290, Spain
关键词
x-ray optics; beamline; monochromator; synchrotron;
D O I
10.1117/12.2024531
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Mistral is the soft X-ray full field microscopy beamline at the ALBA light source. The beamline is designed to have large source acceptance and to provide constant magnification at the exit slit for photon energies between 270 and 2600 eV. The monochromator is a variation of the Petersen plane grating monochromator in which a variable line spacing grating is used to maintain the beam focused at the exit slit, independently of the fixed focus constant, and to cancel aberrations. We present the alignment strategy used to compensate errors of the optical elements, and report about the commissioning results.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Beamline for metrology of x-ray/EUV optics at the advanced light source
    Underwood, JH
    Gullikson, EM
    Koike, M
    Batson, PJ
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 214 - 221
  • [32] The scanning X-ray microprobe at the ESRF "x-ray microscopy" beamline
    Susini, J
    Salomé, M
    Fayard, B
    Ortega, R
    Kaulich, B
    SURFACE REVIEW AND LETTERS, 2002, 9 (01) : 203 - 211
  • [33] Advanced X-ray imaging at beamline 07 of the SAGA Light Source
    Yoneyama, Akio
    Takeya, Satoshi
    Lwin, Thet Thet
    Takamatsu, Daiko
    Baba, Rika
    Konishi, Kumiko
    Fujita, Ryusei
    Kobayashi, Keisuke
    Shima, Akio
    Kawamoto, Masahide
    Setoyama, Hiroyuki
    Ishiji, Kotaro
    Seno, Yoshiki
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1966 - 1977
  • [34] Soft X-ray scanning transmission X-ray microscopy (STXM) of actinide particles
    Nilsson, HJ
    Tyliszczak, T
    Wilson, RE
    Werme, L
    Shuh, DK
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (01) : 41 - 47
  • [35] Soft X-ray scanning transmission X-ray microscopy (STXM) of actinide particles
    Hans J. Nilsson
    Tolek Tyliszczak
    Richard E. Wilson
    Lars Werme
    David K. Shuh
    Analytical and Bioanalytical Chemistry, 2005, 383 : 41 - 47
  • [36] Construction of a soft X-ray beamline at the PLS
    Hwanga, H. -N.
    Kima, H. -S.
    Kim, B.
    Hwang, C. C.
    Moon, S. W.
    Chung, S. M.
    Jeon, C.
    Park, C. -Y.
    Chae, K. H.
    Choi, W. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (03): : 850 - 855
  • [37] The LNLS soft X-ray spectroscopy beamline
    Tolentino, H.
    Compagnon-Cailhol, V.
    Vicentin, F.C.
    Abbate, M.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 539 - 541
  • [38] The LNLS soft X-ray spectroscopy beamline
    Tolentino, H
    Compagnon-Cailhol, V
    Vicentin, FC
    Abbate, M
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 539 - 541
  • [39] Considerations for a soft x-ray spectromicroscopy beamline
    Winn, B
    Hao, X
    Jacobsen, C
    Kirz, J
    Miao, J
    Wirick, S
    Ade, H
    Buckley, C
    Howells, M
    Hulbert, S
    McNulty, I
    Oversluizen, T
    OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 : 100 - 109
  • [40] The Soft X-ray Spectromicroscopy Beamline at SSRF
    Guo, Z.
    Tai, R.
    Wand, Y.
    Yan, R.
    Chen, M.
    Wu, Y.
    Chen, J.
    Xue, S.
    Xu, H.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 164 - 167