Long-Term Outcomes After Cryoballoon Pulmonary Vein Isolation Results From a Prospective Study in 605 Patients

被引:123
|
作者
Vogt, Juergen [1 ]
Heintze, Johannes [1 ]
Gutleben, Klaus J. [1 ]
Muntean, Bogdan [1 ]
Horstkotte, Dieter [1 ]
Noelker, Georg [1 ]
机构
[1] Ruhr Univ Bochum, Dept Cardiol, Heart & Diabet Ctr North Rhine Westphalia, D-32545 Bad Oeynhausen, Germany
关键词
cryoballoon ablation; observational study; paroxysmal atrial fibrillation; pulmonary vein isolation; PAROXYSMAL ATRIAL-FIBRILLATION; CATHETER ABLATION; EUROPEAN-SOCIETY; TASK-FORCE; MANAGEMENT; EFFICACY; SAFETY;
D O I
10.1016/j.jacc.2012.09.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to investigate long-term outcomes of freedom from atrial fibrillation (AF) after pulmonary vein (PV) isolation using cryoballoon ablation with balloon-size selection based on individual PV diameters. Background Data are lacking on long-term outcomes from cryoablation and on the most effective balloon size. Methods This was a prospective observational study involving 605 consecutively enrolled patients with symptomatic paroxysmal AF (n = 579) or persistent AF. Cryoballoon size was based on magnetic resonance imaging and/or conventional angiograms. Patients were followed up every 3 months during the first year after discharge and every 6 months in the second year. After 24 months, follow-up was on an outpatient basis with documented AF episodes recorded. Results The PV isolation was achieved without touch-up in 91.1% of patients, using the smaller balloon in 26.7%, the larger balloon in 25.6%, and both balloons in 47.7% of patients. Follow-up data for >12 months (median 30 months; interquartile range 18 to 48 months) were available for 451 patients, 278 (61.6%) of whom were free of AF recurrence with no need for repeat procedures after the 3-month blanking period. Rates of freedom from AF after 1, 2, and 3 repeat procedures (using cryoballoon or radiofrequency ablation with similar success rates) were 74.9%, 76.2%, and 76.9%, respectively. Use of the smaller balloons or both balloons produced the highest rates of long-term freedom from AF. Phrenic nerve palsy occurred in 12 patients (2%), resolving within 3 to 9 months. Conclusions Rates of long-term freedom from AF after cryoballoon ablation are similar to those reported for radiofrequency ablation. A choice between balloons may improve outcomes. (J Am Coll Cardiol 2013;61:1707-12) (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:1707 / 1712
页数:6
相关论文
共 50 条
  • [21] Esophageal Endoscopy Results After Pulmonary Vein Isolation Using the Single Big Cryoballoon Technique
    Fuernkranz, Alexander
    Chun, K. R. Julian
    Metzner, Andreas
    Nuyens, Dieter
    Schmidt, Boris
    Burchard, Andre
    Tilz, Roland
    Ouyang, Feifan
    Kuck, Karl Heinz
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (08) : 869 - 874
  • [22] Immediate and long-term outcomes of cryoballoon catheter ablation in patients with atrial fibrillation and left common pulmonary vein anatomy
    Yorgun, Hikmet
    Canpolat, Ugur
    Gumeler, Ekim
    Oksul, Metin
    Sener, Yusuf Ziya
    Ates, Ahmet Hakan
    Akkaya, Fatih
    Karahan, Sevilay
    Hazirolan, Tuncay
    Aytemir, Kudret
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (01) : 57 - 65
  • [23] A case of pulmonary vein reconnection after long-term success of pulmonary vein isolation for atrial fibrillation
    Ukita, Kohei
    Egami, Yasuyuki
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Nishino, Masami
    JOURNAL OF ARRHYTHMIA, 2024, 40 (06) : 1490 - 1493
  • [24] Long-term outcomes of pulmonary vein isolation using second-generation cryoballoon during atrial fibrillation ablation
    Canpolat, Ugur
    Kocyigit, Duygu
    Yalcin, Muhammed Ulvi
    Coteli, Cem
    Sener, Yusuf Ziya
    Oksul, Metin
    Gurses, Kadri Murat
    Evranos, Banu
    Yorgun, Hikmet
    Aytemir, Kudret
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 910 - 921
  • [25] Vasovagal responses during cryoballoon pulmonary vein isolation in paroxysmal atrial fibrillation predict favorable mid-term outcomes
    Te, Abigail Louise D.
    Lo, Li-Wei
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Hu, Yu-Feng
    Chung, Fa-Po
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Chang, Yao-Ting
    Lin, Chin-Yu
    Yamada, Shinya
    Chang, Ting-Yung
    Salim, Simon
    Minh Quang Hoang
    Huang, Ting-Chun
    Chen, Shih-Ann
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 258 : 115 - 120
  • [26] Cryoballoon Versus Radiofrequency for Pulmonary Vein Re-Isolation After a Failed Initial Ablation Procedure in Patients with Paroxysmal Atrial Fibrillation
    Pokushalov, Evgeny
    Romanov, Alexander
    Artyomenko, Sergey
    Baranova, Vera
    Losik, Denis
    Bairamova, Sevda
    Karaskov, Alexander
    Mittal, Suneet
    Steinberg, Jonathan S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (03) : 274 - 279
  • [27] Early recurrence after pulmonary vein isolation is associated with inferior long-term outcomes: Insights from a retrospective cohort study
    Kalinsek, Tine Prolic
    Kottmaier, Marc
    Telishevska, Marta
    Berger, Florian
    Semmler, Verena
    Popa, Miruna
    Brkic, Amir
    Lengauer, Sarah
    Otgonbayar, Ulamnemekh
    Koch-Buettner, Katharina
    Bartowiak, Marcin
    Kornmayer, Marielouise
    Brooks, Stephanie
    Risse, Elena
    Kathan, Susanne
    Hofmann, Monika
    Grebmer, Christian
    Reents, Tilko
    Hessling, Gabriele
    Deisenhofer, Isabel
    Bourier, Felix
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (10): : 1156 - 1164
  • [28] Long-term clinical outcomes of magnetically navigated rotor ablation as an adjunct to conventional pulmonary vein isolation
    Shukla, Gunjan
    Zimmerman, John
    Shir, Zoya
    Shah, Roshan
    Hasanaj, Edmund
    EUROPACE, 2018, 20 : 40 - 47
  • [29] Pulmonary vein capture is a predictor for long-term success of stand-alone pulmonary vein isolation with cryoballoon ablation in patients with persistent atrial fibrillation
    Babak, Alexey
    Kauffman, Christine Bienvenue
    Lynady, Cynthia
    McClellan, Reginald
    Venkatachalam, Kalpathi
    Kusumoto, Fred
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 10
  • [30] Validation Strategy for Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation in Long-Term Maintaining Sinus Rhythm: A Randomized Controlled Study
    Li, Xinyu
    Yu, Houdeng
    Lai, Shihuang
    Liao, Yaqi
    Yang, Yihong
    Tian, Kejun
    Zhong, Yiming
    Chen, Xinguang
    CARDIOLOGY RESEARCH AND PRACTICE, 2024, 2024