Three-year clinical follow-up after Palmaz-Schatz stenting

被引:62
作者
Klugherz, BD [1 ]
DeAngelo, DL [1 ]
Kim, BK [1 ]
Herrmann, HC [1 ]
Hirshfeld, JW [1 ]
Kolansky, DM [1 ]
机构
[1] UNIV PENN,MED CTR,DIV CARDIOVASC,PHILADELPHIA,PA 19104
关键词
D O I
10.1016/0735-1097(95)00574-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Our goals were to examine late clinical outcome in a cohort of patients who electively received Palmaz-Schatz intracoronary stents, to identify specific predictors of outcome and to determine the time course of the development of ischemic cardiac events after stenting. Background. Short-term results of Palmaz-Schatz intracoronary stenting have been promising, with a reduction in both angiographic restenosis and clinical cardiac events up to 1 year after stenting. Methods. We analyzed the clinical outcomes in 65 consecutive patients who underwent stenting at least 3 years before analysis, Demographic, clinical and procedural predictors of survival and event free survival, defined as freedom from myocardial infarction, stent-site percutaneous transluminal coronary angioplasty, coronary artery bypass graft surgery or death, were analyzed at a mean follow-up of 39 +/- 17 months. Results. Absolute survival and event-free survival at 3 years were 88% and 56%, respectively. Three-year freedom from stent-site revascularization was 66%. Predictors of decreased long-term survival (p < 0.05) included diabetes and a high angina score (Canadian Cardiovascular Society class III/IV) at 6 and 12 months after stenting. Predictors of decreased event-free survival (p < 0.05) included a high angina score at 3, 6 and 12 months after stenting, smaller stent deployment balloon size and greater number of stents implanted. Freedom from adverse events by 6 months after stenting also correlated with long-term event free survival. Eighty five percent of stent-site revascularizations occurred within 1 year. During late follow-up (>24 months), no patients had stent-site stenoses requiring revascularization, whereas 11% of patients required revascularization in nonstented coronary segments. Conclusions. Clinical predictors of worse long-term. outcome included diabetes mellitus, higher angina score at follow-up, smaller stent deployment balloon size and greater number of stents at implantation. During follow-up, the majority of adverse events and stent-site revascularizations occurred early after stenting, and disease progression in nonstented vessels accounted for the majority of late revascularization events.
引用
收藏
页码:1185 / 1191
页数:7
相关论文
共 19 条
[1]   DIRECTIONAL CORONARY ATHERECTOMY - HOW MUCH LUMEN ENLARGEMENT IS OPTIMAL [J].
BAIM, DS ;
KUNTZ, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (13) :E65-E70
[2]   GRADING OF ANGINA-PECTORIS [J].
CAMPEAU, L .
CIRCULATION, 1976, 54 (03) :522-523
[3]   RESTENOSIS AFTER ARTERIAL INJURY CAUSED BY CORONARY STENTING IN PATIENTS WITH DIABETES-MELLITUS [J].
CARROZZA, JP ;
KUNTZ, RE ;
FISHMAN, RF ;
BAIM, DS .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (05) :344-349
[4]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[5]   COMPLICATIONS AND FOLLOW-UP AFTER INTRACORONARY STENTING - CRITICAL ANALYSIS OF A 6-YEAR SINGLE-CENTER EXPERIENCE [J].
EECKHOUT, E ;
GOY, JJ ;
VOGT, P ;
STAUFFER, JC ;
SIGWART, U ;
KAPPENBERGER, L .
AMERICAN HEART JOURNAL, 1994, 127 (02) :262-272
[6]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[7]   SAFETY, SUCCESS, AND RESTENOSIS AFTER ELECTIVE CORONARY IMPLANTATION OF THE PALMAZ-SCHATZ STENT IN 100 PATIENTS AT A SINGLE CENTER [J].
FOLEY, JB ;
PENN, IM ;
BROWN, RIG ;
MURRAYPARSONS, N ;
WHITE, J ;
GALLIGAN, L ;
MACDONALD, C .
AMERICAN HEART JOURNAL, 1993, 125 (03) :686-694
[8]   QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS [J].
HAUDE, M ;
ERBEL, R ;
ISSA, H ;
MEYER, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :26-34
[9]   SUBACUTE THROMBOTIC COMPLICATIONS AFTER INTRACORONARY IMPLANTATION OF PALMAZ-SCHATZ STENTS [J].
HAUDE, M ;
ERBEL, R ;
ISSA, H ;
STRAUB, U ;
RUPPRECHT, HJ ;
TREESE, N ;
MEYER, J .
AMERICAN HEART JOURNAL, 1993, 126 (01) :15-22
[10]   GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY [J].
KUNTZ, RE ;
GIBSON, CM ;
NOBUYOSHI, M ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :15-25