Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability

被引:45
|
作者
Yang, Yong Liang [1 ]
Zhou, Dong Sheng [1 ]
He, Ji Liang [1 ]
机构
[1] Shandong Univ, Shandong Prov Hosp, Dept Orthopaed, Jinan 250021, Peoples R China
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2013年 / 26卷 / 03期
关键词
atlantoaxial instability; C1 lateral mass; C2; pedicle; screw fixation; 3-dimensional fluoroscopy; image-guided surgery; TECHNICAL NOTE; C1-C2; FUSION; FIXATION; ACCURACY; FRACTURES; INSERTION; STABILIZATION; SPINE;
D O I
10.1097/BSD.0b013e31823d36b6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A retrospective study. Objective: The aim of the study was to compare the precision of C1 lateral mass and C2 pedicle (C1LM-C2P) screw fixation for atlantoaxial instability using the isocentric C-arm 3-dimensional (Iso-C 3D) navigation versus conventional fluoroscopy. Summary of Background Data: The Iso-C 3D navigation has been widely used in spinal surgeries in recent years. The advantages of this navigation system compared with conventional fluoroscopy in C1LM-C2P screw fixation for atlantoaxial instability are not known. Methods: Twenty-four patients diagnosed with atlantoaxial instability were treated with C1LM-C2P screw fixation in this study. The navigation group included 12 patients and the other 12 patients were in the conventional fluoroscopy group. The clinical and radiographic results were recorded and compared between the 2 groups. Patients were followed up with clinical examination and radiographs at a mean of 10.8 months. Results: There were no significant differences between groups in the mean age, gender, and causes of atlantoaxial instability. Operative time was 130 +/- 5.4 minutes in the navigation group versus 145 +/- 6.5 minutes in the conventional fluoroscopy group. The mean blood loss in the navigation group was 304.2 +/- 47.9 mL relative to 462.5 +/- 55.4 mL in the conventional fluoroscopy group. The radiation time was significantly reduced using 3D navigation (47.5 +/- 1.5 s vs. 64.0 +/- 3.0 s). 95.8% (46/48) of 3D navigated screws and 83.3% (40/48) of fluoroscopy screws had no pedicle perforation. Each patient showed evidence of solid fusion after 6 months on cervical plain radiographies. Conclusion: On comparing the 2 imaging techniques, it was found that using Iso-C 3D navigation can significantly improve the accuracy of screw placement and decrease intraoperative fluoroscopic time and blood loss. This study demonstrates that Iso-C 3D navigation is a safe and effective means of guiding C1LM-C2P screw fixation for atlantoaxial instability.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 50 条
  • [41] Guideline for C1 Lateral Mass and C2 Pedicle Screw Choices in Children Younger Than 6 Years
    Fan, Daoyang
    Song, Ruipeng
    Zhang, Min
    Bai, Ruimin
    Li, Yue
    Zhang, Zhen
    Wu, Han
    Wang, Yuqiang
    Zhao, Liang
    Gao, Wenfei
    Dong, Hui
    Liao, Wensheng
    Liu, Yilin
    Zhang, Yi
    Wang, Limin
    Wang, Weidong
    SPINE, 2017, 42 (16) : E949 - E955
  • [42] Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1-C2 pedicle screw-rod fixation for atlantoaxial instability
    Shen, Kai
    Deng, Zhongliang
    Yang, Junsong
    Liu, Chao
    Zhang, Ranxi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (10) : 1349 - 1355
  • [43] Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients
    Li, Xueshi
    Ai, Fuzhi
    Xia, Hong
    Wu, Zenghui
    Ma, Xiangyang
    Yin, Qingshui
    EUROPEAN SPINE JOURNAL, 2014, 23 (08) : 1712 - 1719
  • [44] Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion: A Preliminary Report
    Yoon, Sang-Mok
    Baek, Jin-Wook
    Kim, Dae-Hyun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (02) : 120 - 125
  • [45] C2 Nerve Dysfunction Associated with C1 Lateral Mass Screw Fixation
    Huang, Da-geng
    Hao, Ding-jun
    Li, Guang-lin
    Guo, Hao
    Zhang, Yu-chen
    He, Bao-rong
    ORTHOPAEDIC SURGERY, 2014, 6 (04) : 269 - 273
  • [46] Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation
    Liu Ya-jun
    Tian Wei
    Liu Bo
    Li Qin
    Hu Lin
    Li Zhi-yu
    Yuan Qiang
    Lue Yan-wei
    Sun Yu-zhen
    CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 2995 - 2998
  • [47] Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod
    Jeon, Sei Woong
    Jeong, Je Noon
    Choi, Gi Hoon
    Moon, Seung Myung
    Hwang, Hyung Sik
    Choi, Sun Kil
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 539 - 544
  • [48] A New Technique for the Surgical Treatment of Atlantoaxial Instability: C1 Lateral Mass and C2-3 Transfacet Screwing
    Senturk, Salim
    Akyoldas, Goktug
    Yaman, Onur
    Ozer, Ali Fahir
    TURKISH NEUROSURGERY, 2018, 28 (05) : 843 - 846
  • [49] Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws
    Kiran, Narayanam Anantha Sai
    Sivaraju, Laxminadh
    Vidyasagar, Kanneganti
    Aryan, Sarita
    Raj, Vivek
    Rajagopal, Niranjana
    Mohan, Dilip
    Thakar, Sumit
    Rao, Arun Sadashiva
    Hegde, Alangar S.
    WORLD NEUROSURGERY, 2018, 118 : E304 - E315
  • [50] Radiographic Evaluation of the Technique for C1 Lateral Mass and C2 Pedicle Screw Fixation in Three Hundred Nineteen Cases
    Wang, Shenglin
    Wang, Chao
    Wood, Kirkham B.
    Yan, Ming
    Zhou, Haitao
    SPINE, 2011, 36 (01) : 3 - 8