A Monte Carlo study on the feasibility of real-time in vivo source tracking during ultrasound based HDR prostate brachytherapy treatments

被引:8
作者
Poder, Joel [1 ,2 ]
Cutajar, Dean [1 ,2 ]
Guatelli, Susanna [1 ]
Petasecca, Marco [1 ]
Howie, Andrew [2 ]
Bucci, Joseph [2 ]
Carrara, Mauro [3 ]
Rosenfeld, Anatoly [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Northfields Ave, Wollongong, NSW 2500, Australia
[2] St George Hosp Canc Care Ctr, Kogarah, NSW, Australia
[3] Fdn IRCCS Ist Nazl Tumori, Med Phys Unit, Via Giacomo Venezian 1, I-20133 Milan, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 59卷
关键词
In vivo; Source tracking; Real-time prostate brachytherapy; Magic Plate; MP900; Monte Carlo; DOSE-RATE BRACHYTHERAPY; EXTERNAL-BEAM RADIOTHERAPY; PRETREATMENT VERIFICATION; RANDOMIZED-TRIAL; QUALITY; CANCER; CT; RECOMMENDATIONS; RECONSTRUCTION; COMBINATION;
D O I
10.1016/j.ejmp.2019.02.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to assess the accuracy of in-vivo source tracking during real-time trans-rectal ultrasound (TRUS) based high dose rate (HDR) prostate brachytherapy (pBT) through Monte Carlo simulations of multiple HDR pBT treatments with a two-dimensional (2D) diode array, the Magic Plate 900 (MP900), embedded below the patient in a carbon-fibre couch. Method: Monte Carlo simulations of source positions representing three separate real-time TRUS based HDR pBT treatments were performed using the Geant4 toolkit. For each source position, an Ir-192 source was simulated inside a voxelized patient geometry. Dose deposited from each source position to the MP900 diodes was used to perform source tracking, and the MP900 calculated position compared to known source positions from the treatment plan. Thresholding techniques were implemented to improve source tracking accuracy with the TRUS probe present. Results: The average three-dimensional source position reconstruction discrepancy was 11.9 +/- 2.4 mm and 1.5 +/- 0.3 mm with and without the TRUS probe, respectively. Thresholding techniques improved the source position reconstruction discrepancy in the presence of the TRUS probe to 1.8 +/- 0.4 mm. Conclusion: Inclusion of the TRUS probe inside the patient negatively affects source tracking accuracy when using the MP900 diode array for HDR pBT verification. Modification of the source tracking algorithm using thresholding techniques improves source tracking in the presence of the TRUS probe, achieving similar accuracy as when the TRUS probe is not present. This study demonstrates that accurate in-vivo source tracking during real-time TRUS based HDR pBT is feasible using the Magic Plate system.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 33 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Geant4 developments and applications
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Dubois, PA
    Asai, M
    Barrand, G
    Capra, R
    Chauvie, S
    Chytracek, R
    Cirrone, GAP
    Cooperman, G
    Cosmo, G
    Cuttone, G
    Daquino, GG
    Donszelmann, M
    Dressel, M
    Folger, G
    Foppiano, F
    Generowicz, J
    Grichine, V
    Guatelli, S
    Gumplinger, P
    Heikkinen, A
    Hrivnacova, I
    Howard, A
    Incerti, S
    Ivanchenko, V
    Johnson, T
    Jones, F
    Koi, T
    Kokoulin, R
    Kossov, M
    Kurashige, H
    Lara, V
    Larsson, S
    Lei, F
    Link, O
    Longo, F
    Maire, M
    Mantero, A
    Mascialino, B
    McLaren, I
    Lorenzo, PM
    Minamimoto, K
    Murakami, K
    Nieminen, P
    Pandola, L
    Parlati, S
    Peralta, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 270 - 278
  • [3] Apostolakis J, P 2008 IEEE NSS MIC
  • [4] Aso T, 2007, IEEE NUCL SCI CONF R, P2576
  • [5] HIGH-DOSE-RATE BRACHYTHERAPY AS A MONOTHERAPY FOR FAVORABLE-RISK PROSTATE CANCER: A PHASE II TRIAL
    Barkati, Maroie
    Williams, Scott G.
    Foroudi, Farshad
    Tai, Keen Hun
    Chander, Sarat
    van Dyk, Sylvia
    See, Andrew
    Duchesne, Gillian M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1889 - 1896
  • [6] Intraoperative ultrasound-based planning can effectively replace postoperative CT-based planning for high-dose-rate brachytherapy for prostate cancer
    Batchelar, Deidre L.
    Chung, Hans T.
    Loblaw, Andrew
    Law, Niki
    Cisecki, Thomas
    Morton, Gerard C.
    [J]. BRACHYTHERAPY, 2016, 15 (04) : 399 - 405
  • [7] Beaulieu L, 2017, BRACHYTHERAPY
  • [8] Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation
    Beaulieu, Luc
    Tedgren, Asa Carlsson
    Carrier, Jean-Francois
    Davis, Stephen D.
    Mourtada, Firas
    Rivard, Mark J.
    Thomson, Rowan M.
    Verhaegen, Frank
    Wareing, Todd A.
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6208 - 6236
  • [9] In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: Comparison with planned and reconstructed doses
    Carrara, Mauro
    Tenconi, Chiara
    Rossi, Giulio
    Borroni, Marta
    Cerrotta, Annamaria
    Grisotto, Simone
    Cusumano, Davide
    Pappalardi, Brigida
    Cutajar, Dean
    Petasecca, Marco
    Lerch, Michael
    Gambarini, Grazia
    Fallai, Carlo
    Rosenfeld, Anatoly
    Pignoli, Emanuele
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 (01) : 148 - 153
  • [10] A review of the recommendations governing quality assurance of ultrasound systems used for guidance in prostate brachytherapy
    Doyle, Andrea Jane
    King, Deirdre M.
    Browne, Jacinta E.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 51 - 57