Development and validation of a 3D-printed bolus cap for total scalp irradiation

被引:39
作者
Baltz, Garrett C. [1 ,2 ]
Chi, Pai-Chun Melinda [1 ,2 ]
Wong, Pei-Fong [1 ]
Wang, Congjun [1 ,2 ]
Craft, Daniel F. [1 ,2 ]
Kry, Stephen F. [1 ,2 ]
Lin, Stacy Sydney Hsinyi [1 ]
Garden, Adam S. [3 ]
Smith, Susan A. [1 ]
Howell, Rebecca M. [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Med Phys Program, UTHlth Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
3D printing; bolus; dosimetry; total scalp irradiation; THERAPY; FABRICATION; LESIONS;
D O I
10.1002/acm2.12552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The goal of total scalp irradiation (TSI) is to deliver a uniform dose to the scalp, which requires the use of a bolus cap. Most current methods for fabricating bolus caps are laborious, yet still result in nonconformity and low reproducibility, which can lead to nonuniform irradiation of the scalp. We developed and validated patient-specific bolus caps for TSI using three-dimensional (3D) printing. Methods and materials 3D-printing materials were radiologically analyzed to identify a material with properties suitable for use as a bolus cap. A Python script was developed within a commercial treatment planning system to automate the creation of a ready-to-print, patient-specific 3D bolus cap model. A bolus cap was printed for an anthropomorphic head phantom using a commercial vendor and a computed tomography simulation of the anthropomorphic head phantom and bolus cap was used to create a volumetric-modulated arc therapy TSI treatment plan. The planned treatment was delivered to the head phantom and dosimetric validation was performed using thermoluminescent dosimeters (TLD). The developed procedure was used to create a bolus cap for a clinical TSI patient, and in vivo TLD measurements were acquired for several fractions. Results Agilus-60 was validated as a new 3D-printing material suitable for use as bolus. A 3D-printed Agilus-60 bolus cap had excellent conformality to the phantom scalp, with a maximum air gap of 4 mm. TLD measurements showed that the bolus cap generated a uniform dose to the scalp within a 2.7% standard deviation, and the delivered doses agreed with calculated doses to within 2.4% on average. The patient bolus was conformal and the average difference between TLD measured and planned doses was 5.3%. Conclusions We have developed a workflow to 3D-print highly conformal bolus caps for TSI and demonstrated these caps can reproducibly generate a uniform dose to the scalp.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 19 条
[1]  
Akazawa C, 1989, Med Dosim, V14, P129
[2]   Treatment of extensive scalp lesions with segmental intensity-modulated photon therapy [J].
Bedford, JL ;
Childs, PJ ;
Hansen, VN ;
Warrington, AP ;
Mendes, RL ;
Glees, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1549-1558
[3]   Use of 3D printers to create a patient-specific 3D bolus for external beam therapy [J].
Burleson, Sarah ;
Baker, Jamie ;
Hsia, An Ting ;
Xu, Zhigang .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03) :166-178
[4]  
Chiu T, 2018, PRACT RADIAT ONCOL, V8, pE167, DOI 10.1016/j.prro.2017.11.001
[5]   Design, fabrication, and validation of patient-specific electron tissue compensators for postmastectomy radiation therapy [J].
Craft, Daniel F. ;
Balter, Peter ;
Woodward, Wendy ;
Kry, Stephen F. ;
Salehpour, Mohammad ;
Ger, Rachel ;
Peters, Mary ;
Baltz, Garrett ;
Traneus, Erik ;
Howell, Rebecca M. .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 8 :38-43
[6]   Material matters: Analysis of density uncertainty in 3D printing and its consequences for radiation oncology [J].
Craft, Daniel F. ;
Kry, Stephen F. ;
Balter, Peter ;
Salehpour, Mohammad ;
Woodward, Wendy ;
Howell, Rebecca M. .
MEDICAL PHYSICS, 2018, 45 (04) :1614-1621
[7]   Preparation and fabrication of a full-scale, sagittal-sliced, 3D-printed, patient-specific radiotherapy phantom [J].
Craft, Daniel F. ;
Howell, Rebecca M. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05) :285-292
[8]   Scalp uniform bolus application (SCUBA) technique for homogenous scalp and regional nodal irradiation [J].
Hadziahmetovic, Mersiha ;
Weldon, Michael ;
Pearson, Megan ;
Werner, Patty ;
Siddiqui, Farzan .
PRACTICAL RADIATION ONCOLOGY, 2014, 4 (01) :E95-E99
[9]   UNCERTAINTY ANALYSIS OF ABSORBED DOSE CALCULATIONS FROM THERMOLUMINESCENCE DOSIMETERS [J].
KIRBY, TH ;
HANSON, WF ;
JOHNSTON, DA .
MEDICAL PHYSICS, 1992, 19 (06) :1427-1433
[10]   A highly reproducible Bolus immobilization technique for the treatment of scalp malignancies [J].
Lin, Steven H. ;
Latronico, Diane ;
Teslow, Terrance ;
Bajaj, Gopal K. .
MEDICAL DOSIMETRY, 2008, 33 (01) :30-35