Comparison of periprocedural and long term outcomes of proximal versus distal cerebral protection method during carotid artery stenting

被引:1
|
作者
Gul, Zeynep Bastug [1 ]
Akkaya, Emre [2 ]
Vuruskan, Ertan [3 ]
Akgul, Ozgur [2 ]
Pusuroglu, Hamdi [2 ]
Surgit, Ozgur [2 ]
Ozyilmaz, Sinem Ozbay [2 ]
Tosu, Aydin Rodi [2 ]
Cakmak, Huseyin Altug [4 ]
Gode, Safa [5 ]
Gul, Mehmet [2 ]
机构
[1] Dr Mazhar Osman Teaching & Res Hosp Mental Hlth &, Dept Neurol, TR-34303 Istanbul, Turkey
[2] Mehmet Akif Ersoy Thorac & Cardiovasc Surg Traini, Dept Cardiol, TR-34303 Istanbul, Turkey
[3] Gaziantep State Hosp, Gaziantep, Turkey
[4] Rize Kackar Govt Hosp, Dept Cardiol, Rize, Turkey
[5] Mehmet Akif Ersoy Thorac & Cardiovasc Surg Traini, Dept Cardiovasc Surg, TR-34303 Istanbul, Turkey
关键词
Proximal flow blockage protection system; distal protection with a filter; major adverse cerebral and cardiovascular events; VASCULAR COMPLICATIONS; BALLOON OCCLUSION; HIGH-RISK; ENDARTERECTOMY; ANGIOPLASTY; DEVICES; ATHEROEMBOLI; ISCHEMIA; TRIAL;
D O I
10.1024/0301-1526/a000445
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The aim of this study was to assess the periprocedural and one-year outcomes of two different cerebral protection systems used during carotid artery stenting (CAS). Patients and methods: We enrolled 90 consecutive patients with carotid artery stenosis who underwent CAS with a proximal flow blockage protection system (mean age 69.7 +/- 8) or distal protection with a filter (mean age 70.8 +/- 7). Results: CAS was performed successively on 89 patients (99 %). Adverse events were defined as major stroke, minor stroke, transient ischemic attack (TIA), myocardial infarction, and death. Two strokes, one TIA, one death, and one myocardial infarction were observed in-hospital. There were no significant differences in safety or benefits between the proximal flow blockage embolic protection system (n = 45) and the distal filter protection system (n = 45) in terms of clinically apparent cerebral embolism, TIA, death, or myocardial infarction during the periprocedural stage or during the one-year follow-up period. Conclusions: Although it has been shown that the proximal flow blockage cerebral protection system decreases the risk of silent cerebral embolism, it has no advantage over the distal filter protection system in terms of adverse cerebrovascular or cardiac events during the periprocedural stage or during the long-term follow-up period.
引用
收藏
页码:297 / 304
页数:8
相关论文
共 50 条
  • [21] Intolerance to occlusion during carotid artery stenting with proximal protection: causes, mechanisms, treatment and prevention
    Montorsi, Piero
    Mancini, Elisabetta
    Galli, Stefano
    Teruzzi, Giovanni
    Caputi, Luigi
    Ferrari, Cristina
    Troiano, Sarah
    Olivares, Paolo
    Ravagnani, Paolo M.
    Trabattoni, Daniela
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2022, 70 (06) : 751 - 764
  • [22] Microembolization During Carotid Artery Stenting in Patients With High-Risk, Lipid-Rich Plaque A Randomized Trial of Proximal Versus Distal Cerebral Protection
    Montorsi, Piero
    Caputi, Luigi
    Galli, Stefano
    Ciceri, Elisa
    Ballerini, Giovanni
    Agrifoglio, Marco
    Ravagnani, Paolo
    Trabattoni, Daniela
    Pontone, Gianluca
    Fabbiocchi, Franco
    Loaldi, Alessandro
    Parati, Eugenio
    Andreini, Daniele
    Veglia, Fabrizio
    Bartorelli, Antonio L.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (16) : 1656 - 1663
  • [23] Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection
    Harada, Kei
    Kakumoto, Kosuke
    Oshikata, Shogo
    Fukuyama, Kozo
    ACTA NEUROCHIRURGICA, 2018, 160 (06) : 1121 - 1127
  • [24] Long-Term Outcomes of Carotid Artery Stenting in Clinical Practice
    Mudra, Harald
    Staubach, Stephan
    Hein-Rothweiler, Ralph
    Segerer, Manuela
    Strohm, Henning
    Weber, Hannes
    Ledwoch, Jakob
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (09)
  • [25] Cerebral protection with filter devices during carotid artery stenting
    Reimers, B
    Corvaja, N
    Moshiri, S
    Saccà, S
    Albiero, R
    Di Mario, C
    Pascotto, P
    Colombo, A
    CIRCULATION, 2001, 104 (01) : 12 - 15
  • [26] Cerebral Hyperperfusion Syndrome Risk Comparison between Transcarotid Artery Revascularization and Carotid Artery Stenting with Distal Embolic Protection
    Chow, Christopher Y.
    Kang, Naixin
    Kenel-Pierre, Stefan
    Gonzalez, Kathy
    Sussman, Matthew
    Rey, Jorge
    Velazquez, Omaida C.
    Bornak, Arash
    ANNALS OF VASCULAR SURGERY, 2025, 113 : 112 - 119
  • [27] Evidence overview: benefit of cerebral protection devices during carotid artery stenting
    Vos, Jan A.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (02) : 170 - 177
  • [28] Long-term Outcomes of Carotid Artery Stenting: A Single-center Experience
    Fuse, Yutaro
    Kojima, Takao
    Shintai, Kazunori
    Seki, Yukio
    NEUROLOGIA MEDICO-CHIRURGICA, 2020, 60 (03) : 121 - 125
  • [29] Complete Versus Partial Distal Embolic Protection During Renal Artery Stenting
    Kanjwal, Khalil
    Haller, Steven
    Steffes, Michael
    Virmani, Renu
    Shapiro, Joseph I.
    Burket, Mark W.
    Cooper, Christopher J.
    Colyer, William R., Jr.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (06) : 725 - 730
  • [30] Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon
    Iko, Minoru
    Tsutsumi, Masanori
    Aikawa, Hiroshi
    Matsumoto, Yoshihisa
    Go, Yoshinori
    Nii, Kouhei
    Abe, Gorou
    Ye, Iwae
    Nomoto, Yasuyuki
    Kazekawa, Kiyoshi
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (01) : 45 - 49