Diagnosis of On-Load Tap Changer (OLTC) Using Dynamic Resistance Measurement

被引:0
|
作者
Aziz, Mohd Azhar Abdul [1 ]
Talib, Mohd Aizam [1 ]
Arumugam, Ragavan [1 ]
机构
[1] TNB Res Sdn Bhd, Kajang 43000, Selangor, Malaysia
来源
2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO) | 2014年
关键词
On Load Tap Changer; Dynamic Resistance; Transformer Diagnostic;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
On Load Tap Changer (OLTC) is one of the important and most expensive sub-components in a power transformer. The fail operation of OLTC can cause catastrophic failure of in-service power transformers. Proper and adequate maintenance conducted on serviced aged OLTC can reduce the unexpected unavailability and failure rate of power transformer. Nowadays, several off-line and on-line diagnostic techniques have been used to diagnose the condition of load tap changer. These diagnostic results are important to determine the required maintenance on OLTC. In this paper, the condition of OLTC on in-service transformer was assessed using the dynamic resistance measurement. The results from new unit of OLTC installed in power transformer at the factory and on serviced aged OLTC were presented. The findings suggested that the technique is very promising in detecting problem associated with the contact wear and early stage of contact degradation in OLTC.
引用
收藏
页码:494 / 497
页数:4
相关论文
共 50 条
  • [41] Development of calibration device for on-load tap changer tester of transformer
    Yang, Xuemei
    He, Shan
    Zhang, Lun
    Xiao, Peng
    2024 INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL AND CONTROL SYSTEM, EECS 2024, 2024, 2800
  • [42] Reverse action of on-load tap changer in association with voltage collapse
    Ohtsuki, Hiroshi
    Yokoyama, Akihiko
    Sekine, Yasuji
    IEEE Transactions on Power Systems, 1991, 6 (02) : 300 - 306
  • [43] Power system voltage stability affected by on-load tap changer
    Peng, Zhiwei
    Hu, Guogen
    Han, Zhenxiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 18 (06): : 408 - 412
  • [44] Improvement in the performance of on-load tap changer transformers operating in series
    Smith, CA
    Redfern, MA
    Potts, S
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1905 - 1910
  • [45] Power system voltage stability affected by on-load tap changer
    Peng, Zhiwei
    Hu, Guogen
    Han, Zhenxiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 1998, 18 (06): : 408 - 412
  • [46] REVERSE ACTION OF ON-LOAD TAP CHANGER IN ASSOCIATION WITH VOLTAGE COLLAPSE
    OHTSUKI, H
    YOKOYAMA, A
    SEKINE, Y
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (01) : 300 - 306
  • [47] Vibration Analysis Using Variational Mode Decomposition for Mechanical Fault Diagnosis in The Diverter Switch of On-load Tap Changer
    Yang, Ruilin
    Zhang, Dandan
    Li, Zhenbiao
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [48] Condition assessment of power transformer on-load tap-changers (OLTC) using wavelet analysis
    Kang, P
    Birtwhistle, B
    PICA 2001: 22ND IEEE POWER ENGINEERING SOCIETY INTERNATIONAL CONFERENCE ON POWER INDUSTRY COMPUTER APPLICATIONS, 2001, : 330 - 335
  • [49] Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
    Cichon, Andrzej
    Borucki, Sebastian
    Boczar, Tomasz
    ARCHIVES OF ACOUSTICS, 2011, 36 (04) : 823 - 830
  • [50] A STUDY ON THE CONDITION OF REVERSE CONTROL ACTION OF TAP CHANGER IN A SINGLE ON-LOAD TAP CHANGER POWER-SYSTEM
    YORINO, N
    FUNAHASHI, A
    SASAKI, H
    KUBOKAWA, J
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (07) : 44 - 55