Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation

被引:46
|
作者
Koppara, Tobias [1 ]
Joner, Michael [1 ]
Bayer, Gerd [2 ]
Steigerwald, Kristin [1 ]
Diener, Tobias [2 ]
Wittchow, Eric [2 ]
机构
[1] Deutsch Herzzentrum Munich, D-80636 Munich, Germany
[2] BIOTRONIK SE & Co KG, Erlangen, Germany
关键词
Porcine model; sirolimus-eluting stents; restenosis; POOLED ANALYSIS; DURABLE POLYMER; CLINICAL-OUTCOMES; RELEASE PROFILES; COATED STENTS; FOLLOW-UP; IN-VITRO; DRUG; RESTENOSIS; TRIAL;
D O I
10.1160/TH12-01-0043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher (TM)) at 28,90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher (TM) at 28 days, with significant greater reductions at 90 and 180 days (1.7 +/- 0.7 mm(2) vs. 3.1 +/- 1.5 mm(2), p=0.03 and 1.8 +/- 1.2 mm(2) vs. 3.0 +/- 1.5 mm(2), p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher (TM) may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.
引用
收藏
页码:1161 / 1171
页数:11
相关论文
共 50 条
  • [31] Outcomes of patients treated with a biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stents after rotational atherectomy
    Mankerious, Nader
    Hemetsberger, Rayyan
    Traboulsi, Hussein
    Toelg, Ralph
    Abdel-Wahab, Mohamed
    Richardt, Gert
    Allali, Abdelhakim
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (10) : 1574 - 1585
  • [32] Elastic stent recoil in coronary total occlusions: Comparison of durable-polymer zotarolimus eluting stent and ultrathin strut bioabsorbable-polymer sirolimus eluting stent
    Improta, Riccardo
    Scarparo, Paola
    Wilschut, Jeroen
    Wolff, Quinten
    Daemen, Joost
    Den Dekker, Wijnand K.
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Diletti, Roberto
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (01) : 88 - 97
  • [33] Biodegradable Polymer Versus Permanent Polymer Drug-Eluting Stents and Everolimus- Versus Sirolimus-Eluting Stents in Patients With Coronary Artery Disease 3-Year Outcomes From a Randomized Clinical Trial
    Byrne, Robert A.
    Kastrati, Adnan
    Massberg, Steffen
    Wieczorek, Anna
    Laugwitz, Karl-Ludwig
    Hadamitzky, Martin
    Schulz, Stefanie
    Pache, Juergen
    Fusaro, Massimiliano
    Hausleiter, Joerg
    Schoemig, Albert
    Mehilli, Julinda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) : 1325 - 1331
  • [34] Permanent and biodegradable polymer coatings in the absence of antiproliferative drugs in a porcine model of coronary artery stenting
    Koppara, Tobias
    Wittchow, Eric
    Byrne, Robert A.
    Bayer, Gerd
    Diener, Tobias
    Joner, Michael
    EUROINTERVENTION, 2016, 11 (09) : 1020 - 1026
  • [35] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345
  • [36] First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial
    von Birgelen, Clemens
    Asano, Taku
    Amoroso, Giovanni
    Aminian, Adel
    Brugaletta, Salvatore
    Vrolix, Mathias
    Hernandez-Antolin, Rosana
    van de Harst, Pim
    Iniguez, Andres
    Janssens, Luc
    Smits, Pieter C.
    Wykrzykowska, Joanna J.
    Ribeiro, Vasco Gama
    Pereira, Helder
    da Silva, Pedro Canas
    Piek, Jan J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Sabate, Manel
    EUROINTERVENTION, 2018, 13 (17) : 2026 - 2035
  • [37] Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent)
    Vlachojannis, Georgios J.
    Smits, Pieter C.
    Hofma, Sjoerd H.
    Togni, Mario
    Vazquez, Nicolas
    Valdes, Mariano
    Voudris, Vassilis
    Slagboom, Ton
    Goy, Jean-Jaques
    den Heijer, Peter
    van der Ent, Martin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12) : 1215 - 1221
  • [38] Comparison of sirolimus loaded PLGA-PEG Co-polymer coronary stent and bare metal stent in a porcine coronary restenosis model
    Kyung Seob Lim
    Jun-Kyu Park
    Myung Ho Jeong
    Jae-Woon Nah
    Dong-Gon Kim
    In Ho Bae
    Dae Sung Park
    Jong Min Kim
    Jung Ha Kim
    Dong Lyun Cho
    Doo Sun Sim
    Keun-Ho Park
    Young Joon Hong
    Youngkeun Ahn
    Macromolecular Research, 2014, 22 : 639 - 646
  • [39] Tacrolimus-eluting stent with biodegradable polymer is more effective than sirolimus- and everolimus-eluting stent in rabbit iliac artery restenosis model
    Park, Dae Sung
    Park, Jun-Kyu
    Jeong, Myung Ho
    Bae, In-Ho
    Lee, So-Youn
    Jang, Eun Jae
    Lim, Kyung-Seob
    Kim, Jong Min
    Kim, Jung Ha
    Hyun, Dae Young
    Jeong, Yun Ah
    Kim, Hyun Kuk
    Sim, Doo Sun
    MACROMOLECULAR RESEARCH, 2015, 23 (11) : 1034 - 1041
  • [40] Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent
    Zhu, Jinzhou
    Liu, Huizhu
    Cui, Haipo
    Tang, Zhirong
    Song, Chengli
    Zhang, Ruiyan
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2017, 28 (03)